Ariston Thermo USA LLC Full Product Catalog 2021 - HTP
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
Ariston Thermo USA LLC
Full Product
Catalog
2021
® A DIVISION OF
Advanced Heating
& Hot Water SystemsYour New
Right Hand
Man
Search HTP Mobile in the App Store or Google Play or scan below to download today
2HYDRONIC SPACE HEATING
Elite XL Elite Premier Elite FT Pioneer Elite Ultra Elite Fire Tube Ultra
Appliance Commercial Residential & Residential
Type Boilers Commercial Boilers Space Heating
Radiant Floor Yes Yes Yes Yes Yes Yes
Fan Coil Yes Yes Yes Yes Yes Yes
Base Board Max 180˚temp
Snow Melt Yes Yes Yes Yes Yes Yes
Heating
& DHW
w/ Indirect Tank or VWH w/ Indirect Tank
Turndown
Ratio 10:1 10:1 10:1 5:1 up to 1 1 : 1 up to 1 0 : 1
Cascading up to 8 Units
Pool Heater w/ Indirect Tank
ASME Yes Yes Yes Yes
Mass Type Low Mass Low Mass Medium Mass High Mass Medium Mass Medium Mass
Domestic (combi op-
Hot Water VWH VWH tion) (combi option)
Requires Primary/
Secondary Piping
Configuration
No Yes Yes No No No
Integrated Buffer
Tank – Hydronic
Stabilization
No No No 55 Gal. No No
PAGE Number
in the Catalog 6 8 10 12 14 19
COMBINATION HEATING
Elite Ultra Elite Fire Tube Ultra Phoenix Plus Phoenix Phoenix LD
Application Type Combi Units Gas Fired Water Heaters (with Air handler )
Radiant Floor Yes Yes Yes Yes Yes
Fan Coil Yes Yes Yes Yes Yes
Base Board Max 180˚temp Max 180˚temp
Snow Melt Yes Yes
Pool Heater w/ Indirect Tank w/ Indirect Tank
ASME Yes Yes
Co-Generation Heat Recovery Yes Yes Yes
Domestic
Hot Water Yes Yes Yes Yes Yes
Requires Primary/
Secondary Piping Configuration No No No No No
Integrated Buffer Tank –
Hydronic Stabilization No No Yes Yes Yes
PAGE Number
in the Catalog 14 19 22 24 28
3RESIDENTIAL WATER HEATING
Phoenix Crossover Crossover Everlast Everlast
Everlast Everlast Everlast SuperStor SuperStor
Light Duty Wall Floor
Whole Single & Point of Mini Tank Ultra Ultra Max Contender
Home Multipoint Residential Use
Appliance Gas Fired Appliance
Type Gas Fired Hybrid Type Electric Tankless Electric Water Heaters Hydronic Indirects
Storage W.H.
Tank 316 L 316L 316L Titanium 316L 316L Glass Lined
Stainless Tank
Stainless Stainless Stainless Glass- Stainless Stainless w/ Anode
Material Steel Material Lined
Steel Steel Steel Steel Steel Rods
Modulation 3 :1 10 : 1 2 :1 Modulation
Heat 1 Durable 1 Durable 2 Durable 1 Durable 1 Durable 316L Smooth
Heat Cupronickel Stainless Stainless Finned
Exchanger / Titanium Copper Titanium Titanium Copper Stainless Enamel
Exchanger Steel Steel Element Element Element
Cupronickel
Elements Elements Element Steel Coil
Storage Storage Ultra SuperStor
Tank Option Option Option Tank Option CB GL
Combination Double Wall
W/ Auxiliary With Air With Air Option
Domestic &
Space Heating Taps Handler Handler Exchanger
Uniform Two Heat
Energy Factor up to .90 up to .94 up to .89
Exchangers Option
Btuh 76,000 199,000 100,000 Solar Option Yes Yes
PAGE Number Kw Kw Kw Kw Kw
in the Catalog 28 37 33 B tuh / kW 18 to 36 3.1 to 13 4.5 or 5.5 1.5 or 5 1.4 to 2
PAGE Number
in the Catalog 39 40 47 49 51 53 55 57
COMMERCIAL WATER HEATING
Phoenix Phoenix Elite XL Elite Premier Crossover Everlast Everlast Everlast Everlast Everlast Everlast
Everlast
Plus Phoenix Multi-Fit VWH VWH
Whole Single & MD Com
Commercial Home Multipoint 3 Element
Medium Duty Light Duty Point of
Mini Tank
Commercial Commercial Use
Appliance Gas Fired Volume Water Gas Fired
Gas Fired Storage Water Heater Electric Tankless Electric Water Heaters
Type Heaters Hybrid
316 L 316 L 316 L 316L 316L 316L 316L Titanium
Tank
Stainless Stainless Stainless Stainless Stainless Stainless Stainless Glass-
Material
Steel Steel Steel Steel Steel Steel Steel Lined
Modulation up to 10 :1 5 :1 5 :1 10 :1 10 : 1
Heat Cupronickel Cupronickel Cupronickel 316 L 1 Durable 1 Durable 3 Durable 2 Durable 2 Durable 1 Durable 1 Durable
Exchanger/ Stainless
& Stainless & Stainless & Stainless Stainless Steel Titanium Copper Titanium Titanium Titanium Titanium Copper
Steel Steel Steel
Steel
Elements Element Element Elements Elements Elements Element Element
Storage Tank Requires
Requires Storage Tank
Option Storage Tank
Multiple Heat Option
Exchangers
Combination
Domestic & W/ Auxiliary W/ Auxiliary W/ Auxiliary
Space Heating Taps Taps Taps
Cascading up to 18
up to 8 Units
Units
Unit up to 180 º F
High Temp. SA Models Tank up to
Sanitation 160 º F
Btuh Btuh Btuh Btuh Btuh Kw
Btuh Kw Kw Kw Kw Kw Kw
Btuh / kW 199,000 to 100,000 to 130,000 to 399,000 to 220,000 to 12.5 to
199,000 18 to 36 3.1 to 13 3 to 12 4.5 or 5.5 1.5 to 5 1.4 to 2
399,000 199,000 199,000 2,000,000 399, 000 18
PAGE Number
in the Catalog 22 24 26 30 32 35 39 40 41 43 45 50 51
4Large
SSP
Volume
Solar
Solar Tanks
SOLAR TANKS
Solar Electric Large
Appliance with an
Indirect Volume
Type
Back-up Solar
316L
Tank Glass Lined
Stainless
Material Steel
Steel
ASME Yes
Electric Electric or
Heat with a Boiler Backup
Exchanger Stinless Steel - Multiple Large
Backup Coils
Domestic
Hot Water Yes Yes
Limited Up to 1,000
Additional
10 Year Gallons
Information
Warranty Tank Size
PAGE Number
in the Catalog 64 64
STORAGE TANKS
SuperStor SuperStor Large
Ultra SS Glass Lined Volume
Storage Storage Storage
Appliance Storage Storage Storage
Type Tank Tank Tank
316L
Tank Glass Lined Glass Lined
Stainless
Material Steel Steel
Steel
ASME Available Yes
Domestic
Hot Water Yes Yes Yes
5 Sizes: 4 Sizes: 200 Gallons
Additional
30 to 119 50 to 175 up to 5,695
Information
Gallons Gallons Gallons
PAGE Number
in the Catalog 53 60 58
5®
COMMERCIAL HIGH EFFICIENCY CONDENSING BOILER
Low Mass Boiler
FEATURES:
4 pass heat exchanger with large internal circuits
reduces pressure drop, allowing the unit to be used in
variable flow system
Durable 316L stainless steel construction
pressure rated at 160 PSI bears the ASME
Stamp (H)
Combustion System - 10 to 1 turndown
Three Pump Control - System, Boiler & DHW
7" High Resolution Touchscreen Display
Cascade sequencing up to eight (8) boilers – Redundancy
of operation (no downtime) – providing a much
larger turndown ratio while increasing overall
system efficiency and performance with unit
runtime rotation
7 Sizes from HTP LINK - WiFi solution enables
remote monitoring of the appliance and system
399,000 to 2,000,000 Btuh Direct vent up to 150 feet (1,500,000 to 2,000,000
Btuh Units) and up to 125 feet (399,000 to 1,000,000
97 % Thermal Efficiency Btuh Units) using PVC, CPVC, Polypropylene or Stainless
Steel
Ultra-Low NOx Operation
Elite XL Applications: Radiant Floor • Fan Coil • Base Board • Snow Melt • DHW (w/ Indirect Tank) • Pool Heater (w Indirect Tank) • ASME
6 htproducts.com/elitexlModel ELX- A B C D E F
400-500 40.7
41.0 26.0 17.9 35.0 4.1
650-1000 56.5
1500 66.5
60.8 31.8 39.2 44.8 51.2
2000 79.0
Model ELX- G H J K L M AA 399,000 to
400-1000 10.1 10.5 12.6 16.1 20.5 22.0
1,000,000 EE QQ
1500-2000 3.4 7.4 7.5 11.9 14.4 24.4
Btuh Units PP
Model ELX- N O P Q R DD
400-1000 6.1 8.1 25.8 35.0 2.8*
OO
1500-2000 31.8 4.6 6.5 22.7 39.1
BB RR CC FF
GG NN
HH
JJ
KK
LL
MM
SCAQMD Rule 1146.2
A
1,500,000
F
to 2,000,000 E
Btuh Units D R
Q
G P
B C H
J O Heat Exchanger
K
5 Year Limited Commercial Warranty
Bears the ASME
L “H” Stamp
M
N
Model ELX-400FBN ELX-500FBN ELX-650FBN ELX-800FBN ELX-1000FBN ELX-1500FBN ELX-2000FBN
Minimum / Maximum Input (Btu/Hr) 39,900 / 399,000 50,000 / 500,000 65,000 / 650,000 80,000 / 800,000 100,000 / 1,000,000 150,000 / 1,500,000 200,000 / 2,000,000
Heating Capacity (MBH) 387 485 630 776 970 1,455 1,940
Flue System Category IV, Sealed Combustion Direct Vent, Power Vent
Minimum Combined Vent Run 10 feet 15 feet
Maximum Combined Vent Run 4” (125 feet) 6” (125 feet) 8” (150 feet)
Approved Exhaust Vent Materials PVC, CPVC, PP, Stainless Steel
W 32.25 43.25
Packaging
Dimensions H 49.625 64.25
(in Inches)
D 48 64 76 86
Shipping Weight (lbs) 538 545 680 700 745 1400 1750
Gas Supply Pressure 3.5” to 14” WC (NG or LP) 3.5” to 10.5” WC (NG ONLY)
Manifold Pressure Min / Max NG/LP: -0.08” WC NG: -0.07” WC
208/3PH WYE,
Power Supply 120V 60 Hz, 21.3A
60Hz, 15A/Leg
Customer Connection Board Fuse Amperage Ratings 2 Amps 5 Amps
General Operating Conditions Ambient Temperature Range: 33 – 104oF (0.6 – 40oC); Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9, CSD-1 ASME Code
Ignition System Direct Electronic Spark Ignition / Flame Rectification
Burner System Premixed Fuel Modulation / Stainless Steel Burner
Gas Valve System Pneumatic Gas Valve
Boiler Water Content (Gallons) 3.8 4.3 5.6 6.6 8.1 12.9 16.25
Minimum Flow Rate @ 20oF ∆T at Low Fire (GPM) 4 5 6.5 8 10 15 20
Boiler Setpoint Temperature Range 50 – 190oF / 32 - 190oF (with Outdoor Reset Curve)
DHW Indirect Setpoint Temperature Range 70 – 185oF
Heat Exchanger MAWP 160
Water Pressure (PSI)
Pressure Relief Valve 50
Supply / Return 2” NPT 2 1/2” Flange
Connection Sizes
Gas Inlet 1” NPT 1 1/4” NPT 1 1/2” NPT 2” NPT
Cabinet Powder Coated Galvaneal Steel
Materials
Heat Exchanger 316L Stainless Steel Water Tube
710 : 1
Turndown
Premier Ratio
LOW MASS
Up to 96% Efficient
Vents in inexpensive,
easy-to-install PVC pipe,
up to 200 combined feet
State of the art control
interface: a 2 line 20 character
LCD control interface:
Total System Control
Impressive range:
7 models, ranging from
80,000 to 399,000 Btuh
Floor standing or wall mount
12 year limited warranty
2016
316 L Stainless Steel Heat Exchanger
Elite Premier Applications: Radiant Floor • Fan Coil • Base Board • Snow Melt • DHW (w/ Indirect Tank or VWH) • Pool Heater (w/ Indirect Tank) • ASME
8 htproducts.com/elitepremier1 EXHAUST VENT CONNECTION 4 SYSTEM RETURN 7 GAS LINE CONNECTION
1COMBUSTION
EXHAUST VENT CONNECTION 5 4SYSTEM SUPPLY
SYSTEM WITH
RETURN 7 GAS LINE CONNECTION
2 AIR INLET CONNECTION 8 DISPLAY/CONTROL PANEL
INTEGRATED RELIEF VALVE
2 COMBUSTION AIR INLET CONNECTION 6 5 SYSTEM SUPPLY WITH 8 DISPLAY/CONTROL PANEL
3 ELECTRICAL CONNECTIONS CONDENSATE
INTEGRATEDCONNECTION
RELIEF VALVE 9 AIR RELEASE VENT
3 ELECTRICAL CONNECTIONS A 6 CONDENSATE CONNECTION 9 AIR RELEASE VENT
B
C A F 9
J D B N
1 C 8 9
K F
J D N
1 8
K
L
M
L 2
M
2
4
4
5 E
G
5 E
G
TOP 3
TOP 3
6
LEFT SIDE H RIGHT SIDE
6 FRONT
7
LEFT SIDE H RIGHT SIDE
FRONT
7
MODEL* A B C D E F G H J K L M N Shipping Weight
EP-80 18.5” 11.5” 7.75” 4.25” 27” 14.5” 20” 4” 11.75” 7.38” 5.75” 9.75” 4” 108 lbs
EP-110 18.5” 11.5” 7.75” 4.25” 27” 14.5” 20” 4” 11.75” 7.38” 5.75” 9.75” 4” 113 lbs
EP-150 19.5” 12.5” 10.25” 2.50” 27” 14.5” 20” 3.75” 11.75” 7.38” 4.25” 8.25” 4” 126 lbs
EP-220 26.5” 19.5” 15.50” 6.00” 24.25” 14.5” 20” 4.5” 11.75” 7.38” 4.25” 8.25” 4” 164 lbs
1 EXHAUST VENT CONNECTION 4 SYSTEM RETURN 7 CONDENSATE CONNECTION
1COMBUSTION
EXHAUST VENT CONNECTION 5 4 SYSTEM RETURN 7 CONDENSATE CONNECTION
2 AIR INLET CONNECTION SYSTEM SUPPLY 8 GAS LINE CONNECTION
2 COMBUSTION AIR INLET CONNECTION 6 5 SYSTEM SUPPLY 8 GAS LINE CONNECTION
3 ELECTRICAL CONNECTIONS RELIEF VALVE 9 DISPLAY/CONTROL PANEL
3 A
ELECTRICAL CONNECTIONS 6 RELIEF VALVE 9 DISPLAY/CONTROL PANEL
B
C A
D B G 9 O
E C
K D G O
M L E 9
K 1
M L
1
N 2
N 2
4
4
F
5
F
5 3
J
3
6 J
6
TOP 7
TOP 7 LEFT SIDE H RIGHT SIDE
8 FRONT
LEFT SIDE H RIGHT SIDE
8 FRONT
MODEL* A B C D E F G H J K L M N O Shipping Weight
EP-299 24.75” 17.5” 14.5” 7.38” 3.25” 36.5” 14.5” 4.75” 21” 11” 7.88” 4.63” 9.5” 3.5” 211 lbs
EP-301 24.75” 17.5” 14.5” 7.38” 3.25” 36.5” 14.5” 4.75” 21” 11” 7.88” 4.63” 9.5” 3.5” 211 lbs
EP-399 31.75” 24.75” 21.5” 10.75” 3.75” 36” 14.5” 4.75” 21” 11” 7.88” 4.63” 9.5” 3.5” 256 lbs
Model Btuh / Input Range Net Ratings (water) DOE Heating AFUE Supply/Return Exhaust /Air inlet Gas Connection
EP-80 8,000 - 80,000 - 7, 700-77, 000 96.4
EP-110 11,000- 110,000 - 10,600-106,000 96.4 3/4”
1” 3”
EP-150 15,000- 150,000 - 14,300-143,000 95.4
Heat Exchanger
EP-220 22,000- 220,000 - 20,900-209,000 95.2 Bears the ASME
“H” Stamp
EP-299 30,000- 299,000 - 27,400-283,000 94.5
1-1/4” 1”
EP-301 30,000- 301,000 251 Mbh 28,300-289,000 96.1** 4”
EP-399 40,000- 399,000 335 Mbh 37,600-385,000 96.5 ** 1-1/2”
* ”N”Denotes Natural Gas & “LP” Denotes Propane ** Thermal Efficiency (Not AFUE)
9High Efficiency
Medium Mass
Boiler
®
• Energy Star rated: up to 95.1% AFUE
operating efficiency
• Low NOx emission
• Stainless steel fire tube heat exchanger
• Outdoor reset lowers operating set
point automatically
• Unbeatable combined vent length of
up to 150 ft. in 3” PVC pipe (EFT-285)
• Room air intake
• Down fire design, promotes self-cleaning
of combustion system
up to 97%
Efficient • Increased thermal mass provides low
10 :1 Turndown Ratio pressure drop and eliminates short cycling
• Built-in condensate collection system
• Compatible with glycol based systems
2016 • Cascade up to 8 boilers
Elite FT Applications: Radiant Floor • Fan Coil • Base Board • Snow Melt • DHW (w/ Indirect Tank) • Pool Heater (w/ Indirect Tank) • Retro Fit • ASME
10 htproducts.com/eliteftHeating
AFUE
Model Capacity A B C D E F G H J K L M N O P Q
/TE
MBH
EFT-285** 95.1 262 32 5/8” 20 5/8” 11 1/8” 6 7/8” 3 7/8” 2 1/4” 6” 14” 15 1/4” 11 1/8” 7 3/4” 6 7/8” 2 1/4” 13 3/8” 16 5/8” 20”
EFT-399** 97.1* 367 36 3/8” 23 5/8” 13 5/8” 8 1/2” 4 3/4” 2 3/4” 7 3/8” 18 1/8” 18 3/4” 13 5/8” 9 3/4” 8 1/2” 2 3/4” 16 1/2” 19 1/4” 25 1/2”
** add PU to end of stock code to include a pump * Thermal Efficiency (Not AFUE)
H INLET GAS LINE
G H INLE
H OUTLET INLET GAS LINE
G
2016
F OUTLET
G F
E AIR INLET
OUTLET
F E
D AIR INLET
E D AIR INLET
D
J
C
J
C A J K
C A K
Heat Exchanger A K
Bears the ASME
“H” Stamp L CONDENSATE
M L
DRAIN CONDENSA
L M DRAIN
N CONDENSATE
DRAIN
EXHAUST M NO
EXHAUST N
EXHAUST P O
O Q P
Top Vi e w P Q
Q
B
B
Side
B Vi e w B o t to m Vi e w
Model 285 399
STANDARD FEATURES
Installation Indoor, Wall Hung, Fully Condensing
- Up to 95.1% AFUE
Minimum / Maximum Input (Btu/Hr) 28,500 / 285,000 39,900 / 399,000 - Modulating Burner
Heating Capacity (MBH) 262 367* - 10:1 Turndown ratio
- Venting Options
Turndown Ratio 10 : 1 10 : 1
- Concentric
Flue System Category IV, Sealed Combustion Direct Vent, Power Vent - 3” Pipe: Balanced
Minimum Combined Vent Run 16 feet or Unbalanced (EFT-285)
- 4” Pipe (EFT-399)
Maximum Combined Vent Run 3” (150 feet) 4” (200 feet)
- Limited 12 Year Warranty
Approved Exhaust Vent Materials PVC, CPVC, PP, Stainless Steel - Wall Mounted
Shipping Weight (lbs) 203 298 -Total System Control
NG -The Elite FT is ASME Certified
Gas Supply
3.5” to 14” WC
Pressure LP
Manifold
Min / Max NG/LP: -0.01” WC
Pressure INCLUDED IN THE BOX
Power Supply 120V 60 Hz, 6.3A - Temperature and Pressure Gauge
Ambient Temperature Range: 33 – 104oF (0.6 – 40oC) - Pressure Relief Valve 80 PSI
General Operating Conditions - Indirect Sensor & Outdoor Sensor
Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9
- Intake PVC w/ Screens
Ignition System Direct Electronic Spark Ignition / Flame Rectification
- Exhaust PVC Coupling w/ Screens
Burner System Premixed Fuel Modulation / Stainless Steel Metal Fiber Burner - Installation Manual
Gas Valve System Air Ratio Valve - Warranty
- Condensation Removal System
W 20 25.5
Dimensions - Wall Mount
H 32.6 36.4
(in Inches)
D 20.6 23.6
Boiler Water Content (Gallons) 6.1 7.9
Minimum Flow Rate @ 30oF ∆T (GPM) 17.9 25.0 OPTIONAL EQUIPMENT
Boiler Setpoint Temperature Range 50 – 190oF / 32 - 190oF (with Outdoor Reset Curve) - ModBus Adapter
- 3”, 4”, 6” Stainless Steel Outside
DHW Indirect Setpoint Temperature Range 70 – 180oF Termination Vent Kit
Water Pressure Heat Exchanger MAWP 80 - 3” Concentric Vent Kit
(PSI) Pressure Relief Valve 80 - 3” Polypro Vent Kit
- 3” Polypro Pipe
Control Panel / Main Controller LCD Display with LED Indicators / 926 SIT Control
- U.L. 353 Compliant Low Water
Connection Supply / Return 1 1/2” Copper SWT Cutoff w/ Manual Reset
Sizes Gas Inlet 1” NPTF - Alarm System to Monitor Failures
- PC Connection Kit
Cabinet Powder Coated Galvaneal Steel
Materials - Condensate Neutralizer
Heat Exchanger S43932 Stainless Steel Fire Tube - System Sensor
Flame Rectifier Probe, Dual Water Supply Temperature Sensor (199oF), Water - 3 Speed Pump with integrated
Pressure Switch (Min. 10 PSI), Freeze Protection, Blocked Condensate Pressure Flow Check
Safety Devices
Switch, Condensate Trap with Float, Flue Temperature High Limit Sensor (210oF), - LP Conversion Kit
Blocked Vent Pressure Switch, Optional UL353 Low Water Cut-Off
Please refer to the Energy Star website or the rebate center on the HTP website for local rebates 11Pioneer
A Trailblazing Appliance that Installs with the Ease of a Mid-Efficiency
Boiler but has the Performance of a High-Efficiency Product
HIGH MASS
• Modulation provides a 5 to 1
turndown ratio
• Thermal mass in the stainless steel
tank provides a buffer against cycling
during low load conditions
• Low maintenance & space saving design
• Single loop installation: the heat exchanger
is immersed in water and protected
against "flashing" due to low flow condition
• Up to 95% thermal efficiency
• Retro-fit: ideal for replacement systems,
minimize the changes to piping; no primary
secondary piping needed
• Room air intake, PVC and CPVC venting with
combined vent lengths up to 200' in 3” pipe
& up to 85' in 2" for the 100 & 130 models
• Built in dirt & air separator
• 12 year limited warranty
Up to 95% Efficient • 5:1 Turndown Ratio • Single Loop Installation
Pioneer Applications: Radiant Floor • Fan Coil • Base Board • Snow Melt • DHW (w/ Indirect Tank) • Pool Heater (w/ Indirect Tank) • Retro Fit • Buffer Tank
12 htproducts.com/pioneerDimensions & Specificat ions
J J J
PIONEER DIMENSIONS
PIONEER
PIONEER
DIMENSIONS
DIMENSIONS
MODEL # MODEL
MODEL
GALLONS
# # GALLONS
AGALLONS
B A CA B
MODELS BD C ACE D DF B
E G
E F HC
F G J G HDK H J L JE K K LF L G H J K L
PHR100-55 PHR100-55
PHR100-55
PHR-100-55
PHR130-55 PHR130-55
PHR130-55
55 23" PHR-130-55
55 55
53" 23"
6-1/2"
23"53" 53"
8"
6-1/2"
6-1/2"
22" 8" 7-1/2"
8" 53"
22" 22"
8"7-1/2"
7-1/2"
6"
PHR 160-55PHRPHR
160-55
160-55
23" 6.5" 8"34"8" 6"8"
45"6"34"
1-1/4"
34"
45" 45"
22" 1-1/4"
1-1/4"
7.5" 8" 6" 34" 45" 1.25"
PHR-160-55
PHR199-55 PHR199-55
PHR199-55 PHR-199-55
Model
PIONEER SPECIFICATIONS
PIONEER
PIONEER
SPECIFICATIONS PHR-100-55
SPECIFICATIONS PHR-130-55 PHR-160-55 PHR-199-55
AIR AIR AIR
Installation Indoor, Floor Model, Fully Condensing
MODULATION
MODULATION
MODULATION
INTAKE/EX INTAKE/EX
INTAKE/EXSUPPLY/RETURN GAS GASGAS
MODEL # MODEL
MODEL
# # SUPPLY/RETURN SUPPLY/RETURN
SIZES SIZES
AIR
SIZES
VENT AIR VENT
AIR
CONN
VENT SHIPPING
CONN CONNWEIGHT
SHIPPING
SHIPPING
WEIGHT
WEIGHT
RANGE RANGE
RANGE
HAUST HAUST
HAUST . . 94%.
VENT SIZE VENTThermal
SIZE SIZEEfficiency
VENT 95% 95% 95%
PHR100-55 PHR100-55
PHR100-55
33,000-100,000
33,000-100,000
33,000-100,000
2" 2"Input
2" Rate (Btuh) 35,000 ~ 100,000 35,000 ~ 130,000 40,000 ~ 160,000 40,000 ~ 199,000
PHR130-55 PHR130-55
PHR130-55
44,000- 130,000
44,000-
44,000-
130,000
2"
130,000 2" 2"
1-1/4" NPT 1-1/4"
1-1/4"
NPT NPT 1/8" NPT 1/8"1/8" NPT
3/4"
NPT 3/4"
175LBS
3/4" 175LBS
175LBS
PHR 160-55PHRPHR
160-55
53,000-160,000
160-55 53,000-160,000
53,000-160,000
3" 3" Flue
3" System Sealed Combustion Direct Vent, Power Vent
PHR199-55 PHR199-55
PHR199-55
66,000-199,000
66,000-199,000
66,000-199,000
3" 3" 3"
Vent Run 2"(85 ft), 3"(200ft) Vents in PVC - CPVC - SS - ULC S636 Flexible
LP-325-LPolypropylene
LP-325-L Vent Liner
LP-325-L
PIONEER
07-22-10 07-22-10 DIMENSIONS
07-22-10
Weight 260 lbs.
MODEL # GALLONS A B C D E F G
Gas Supply Natural Gas 3.5''W.C ~ 14''W.C
Pressure PHR100-55
Propane Gas 3.5''W.C ~ 14''W.C
PHR130-55
Main Supply 120V55 60 Hz, 6A
23" 53" 6-1/2" 8" 22" 7-1/2" 8"
Power Supply PHR 160-55
Maximum Power 160W
PHR199-55
Ignition System Spark Ignition - Dual Flame Monitoring - Flame Stabilization Monitoring
Burner System High-Grade Inconel Premix Burner
PIONEER SPECIFICATIONS
Gas System AIR Conversion Kit
Retro-fit: ideal Fires on Natural or LP Gas with included
MODEL # MODULATION INTAKE/EX SUPPLY/RETURN SIZES AIR VE
Model Dimensions (W x H x D) RANGE
W 23” x H 53” x HAUST
D 34”
for replacement VENT SIZE
Heat Exchanger Copper Nickel Primary with 800 H and Copper Nickel Secondary Tube Construction
PHR100-55 33,000-100,000 2"
systems, minimize Water Pressure PHR130-55 44,000-12130,000 2"
min - 30 max PSI 1-1/4" NPT 1/8" N
PHR 160-55 53,000-160,000 3"
the changes to Supply/Return PHR199-55 1 1/4'' FNPT 3"
66,000-199,000
Connection Sizes
piping; no primary Gas Inlet 3/4'' NPT
secondary piping Buffer Tank 55 Gallon - 304L Stainless Steel
Warranty Limited 12 Year Residential Warranty
needed
STANDARD FEATURES INCLUDED IN THE BOX OPTIONAL EQUIPMENT
- Modulating Burner - Pressure and Temperature - System Sensor
- 5:1 Turndown Gauge - Indirect Tank Sensor
Ratio - 30 PSI Temperature and - 3”, 4”, 6” Stainless Steel Outside Termination Vent Kit
CAQMD Rule 1146.2
- Venting Options Pressure Relief Valve - 3” PVC Concentric Vent Kit
- Room Air Intake - Intake PVC Tee w/ Screens
TP Ma - Concentric - U.L. 353 Compliant Low Water Cutoff w/ Manual Reset
•H
a d - Exhaust PVC Coupling w/
- Flexible Vent Pipe - Alarm System to Monitor Failures
eI
n Amer i c
Screens
n Amer i c
- Up to 200 combined ft. - PC Connection Kit
- Installation Manual
- Single Loop Installation - Condensate Neutralizer
eI
a
- Outdoor Sensor
• HT Mad
- 12 Year Limited Warranty
P
13ULTRA
Highly Efficient Condensing Boiler & Combi Units
Medium Mass
DURABLE HEATING - BOILER & COMBI UNITS
Boiler Firing Rates: 85,000, 120,000, 150,000, 199,000 Btuh
Combi Firing Rates: 120,000, 150,000, 199,000 Btuh
Condensing technology with a new and patented XtraTech Stainless
Steel Heat Exchanger, ensuring many years of reliable performance
ABSOLUTE EFFICIENCY
Up to 96% AFUE while using an outdoor sensor (included)
Up to 11:1 turndown ratio limits short cycling and provides more ef-
ficient energy consumption
Built-in automatic bypass eliminates expensive primary / secondary
piping
Equipped with a built-in highly efficient ECM Pump
WHISPER QUIET OPERATION
Thanks to a pump and combustion fan with insulating panels
EASY TO USE INTERFACE
LCD display with digits, symbols, and an intuitive menu to easily set
the desired temperature, activate functions, and even manage differ-
ent heating zones ELU-85 - 120 Boiler and 120 - 150 Combi Model Shown
COMBI BOILER: FULL COMFORT SETTING
Domestic hot water preheat function for instant hot water
SMART CONNECTIVITY WITH HTP LINK
The Elite Ultra boiler is always at your fingertips with a WiFi gateway on board, allowing the boiler and its many system
parameters to be monitored remotely
Set up real-time service notifications and maintenance alerts to ensure that the unit is regularly monitored, overdue for
maintenance, or if professional assistance is recommended
EASY TO SERVICE WITH QUICK SNAP COMPONENT AND SENSOR CONNECTIONS
FIFTEEN (15) YEAR LIMITED WARRANTY
FLOOR AND WALL MOUNT MODELS AVAILABLE
14 htproducts.com/eliteultraA Look Inside the ELU-85 - 120 Boiler and 120 - 150 Combi
1 25 1 25
24 24
23 23
1
2 25 21 25
22 22
3 24 3 24
4 4
5 5
23 23
62 21 62 21
7 22
20 7 2022
3 3
84 84
5
95 19 9 19
6 1821 6 1821
7 17
20 7 1720
10
8 8
11
9 16
19 11 1619
9
15
18 1518
12 12
17
14 1417
10
11 16 11 16
13 15 13 15
12 12
14 14
13 Combi Boiler 13 Boiler
Combi Boiler Boiler
1. Pressure relief valve 15. Circulation pump
2. Air purge valve with auto air vent
26 3. Boiler outlet 16. DHW flow switch*
temperature sensor 17. Water pressure switch
4. Air pressure switch 18. Modulating fan
5.1. Flue
Pressure
gas relief valve 15.Boiler
19. Circulation
inlet pump
2. temperature
Air purge valve sensor with auto
temperature airsensor
vent
26
6.3. Main
Boilerheat
outlet
exchanger 17. Water
20. Frame pressure switch
temperature
7. Flame detection sensor
electrode 18. Modulating fan
21. Ignition electrode
4. Air
8 Silencerpressure switch 19.Spark
22. Boilergenerator
inlet
9.5. Junction
Flue gas box temperature sensor
23. Combustion
temperature
10. DWH sensor
heat exchanger* 20.analysis
Frame test point
6. Condensate
11. Main heat exchanger
trap 21.Air
24. Ignition
intakeelectrode
connection
Flame
7. Gas
12. detection electrode
valve 22. Spark generator
25. Exhaust vent 11
8 Silencer
13. Control panel 23.connection
Combustion
9. C.H.
14. Junction
circuitbox
filter analysisvalve
26. Diverter test point
*11. Condensate
Applicable on combitrapunits only. 24. Air intake connection 11
12. Gas valve 25. Exhaust vent
13. Control panel connection
14. C.H. circuit filter 26. Diverter valve
15Specifications
Model ELU-85WBN ELU-120WBN ELU-120WCN ELU-150WCN
Type Boiler Combi
Installation Indoor, Wall Hung, Fully Condensing
Space Heating Minimum / Maximum Input (Btu/Hr)1 9,400 / 85,000 13,200 / 120,000 11,200 / 106,000 13,200 / 120,000
Domestic Hot Water Minimum / Maximum Input (Btu/Hr)1 N/A N/A 11,200 / 114,000 13,200 / 150,000
DOE AFUE2 (%) 96 95 95.5 95
Heating Capacity1, 2 (MBH) 79 111 98 111
Net AHRI Rating, Water (MBH)2 69 97 85 97
35oF Rise N/A N/A 6.8 8.5
Hot Water Capacity 45oF Rise N/A N/A 5.3 6.6
77oF Rise N/A N/A 3.1 3.8
Flue System Category IV, Sealed Combustion Direct Vent, Power Vent
Minimum - Maximum Exhaust Vent Run3 2” (6 - 100 feet), 3” (6 - 150 feet)
Minimum - Maximum Intake Air Pipe Run3 2” (0 - 100 feet), 3” (0 - 150 feet)
Approved Exhaust Vent Materials3 PVC, CPVC, PP, Stainless Steel
Shipping Weight (lbs) 78 84 83 84
Gas Supply NG 3.5” to 10.5” WC
Pressure LP 8” to 13” WC
Power Supply 120V, 60 Hz, less than 12A
Ambient Temperature Range: 33 – 104oF (0.6 – 40oC)
General Operating Conditions
Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9
ELU E
Ignition System Direct Electronic Spark Ignition / Flame Rectification
Burner System Premixed Fuel Modulation / Stainless Steel Burner
Gas Valve System Air Ratio Valve
ELU
ELUELU
W 16” 3/64
Dimensions
(in Inches)
H
Residential43”Condensing
5/8
GasResidential
Boiler Condensin
D 15” 1/8
Approx. Full Boiler Weight (lbs) 88.2 88.6 91 92.8
Boiler Water Content (Gallons) Installation 1.1 Installation
Residential
ResidentialCondensing
Condensing
ResidentialGas
1.2 Condensing
GasBoiler
1.1Boiler Gas Boiler
1.2
Boiler Setpoint Temperature Range 68 – 122oF Low Temperature / 86 - 179oF High Temperature
Commissioning
DHW Indirect Setpoint Temperature Range Commissioning
104 – 149oF
DHW Setpoint RangeInstallation
Installation
(Combi Models) Installation 97 – 140oF
Heat Exchanger MAWP
Maintenance Maintenance
50
Water Pressure (PSI) Commissioning
Commissioning
Commissioning
Pressure Relief Valve 30
DHW Max Pressure N/A N/A 150 150
Parts
Control Panel / Main Controller
Parts
Maintenance
MaintenanceMaintenance AristonThermo LCD Display / AristonThermo GALEVO2 Control
CH Supply / Return 1” Male Sweat with Adapter
Connection
DHW Inlet / Outlet Warranty Warranty
3/4” Male Sweat with Adapter
Sizes Parts
Parts
Gas Inlet
Parts 3/4” Male NPT
Cabinet Painted Steel and Plastic
Materials
Warranty
Warranty
Heat Exchanger Warranty Type 441 Stainless Steel Water Tube
Flame Rectifier Probe, Temperature Limit Control (190oF), Water Pressure Switch (Min. 8 PSI),
Safety Devices Freeze Protection, Blocked Condensate Pressure Switch, Condensate Trap, Flue Temperature
High Limit Sensor (210oF), Blocked Vent Pressure Switch
Table 1 - Technical Specifications
NOTES: DANGER DANGER
1 Listed Input and Output Ratings are at minimum vent lengths at an altitude of 0 - 2000 ft. Numbers will be lower with longer venting and/or altitudes
greater than 2000 ft. Read all instructions in this manual before installing. PerformRead all in
steps instructions
the given in this manual before installing. Per
2 Ratings based on standard test procedures prescribed by the US Department of order.
Energy. order. Failure
Failure to do so could result in substantial property damage, severetopersonal
do so could result in substantial property
injury, or death.
3 The ELU requires a special venting system. Use only the vent materials and methods injury, or death.
DANGER detailedDANGER
DANGER in these installation instructions.
WARNING WARNING
Read
Read
order.
allall
order.
instructions
instructions
Failure
Failure
to to
dodo
in in
this
soproduct
so
this
Improper
could
manual
could
Read
manual
result
order.
all
result
before
installation,
inFailure
warranty in
15 Year Limited Warranty
before
instructions
installing.
installing.
substantial
substantial
and
in this
adjustment, Perform
to do property
cause so
Perform
property
manual
steps
could damage,
property result
steps
alteration,
damage,
damage,
before
in in
thethe
service,installing.
given
orgiven
in substantial
severe
severe
severe personal
Performinstallation,
Improper
maintenance
personal
property
product
personal
stepsvoid
could
damage,
warranty
injury,
in theadjustment,
severe
given
personal
and cause
or death.
alteration, service, or m
property damage, severe per
injury,
injury,
or or
death.
death. Californiainjury, or death.
Proposition 65 Warning: This product contains chemicals California Proposition
known to the 65 Warning: This product contains
State of California
harm. to cause cancer, birth defects, or other
16 WARNING
WARNING
State of California to cause cancer, birth defects, or other reproductive
WARNING
NOTICE NOTICE
Improper
Improper
installation,
installation,
adjustment,
adjustment,
Improper
alteration,
alteration,
installation,
service,
service,
adjustment,
or or
maintenance
maintenance
alteration,
could
could
service,
void
void or maintenance could voidA Look Inside the ELU-150 - 199K BTU Combi/Boiler
24
1. Pressure relief valve
2. Air purge valve 1 25
3. Boiler outlet temperature sensor
4. Air pressure switch 23
5. Flue gas temperature sensor 2
6. Main heat exchanger 5
7. Flame detection electrode
8 Silencer
9. Junction box
3 22
10. DHW Heat Exchanger (Combi Models
Only)
6
11. Condensate trap 21
7
12. Gas valve
13. Control panel
15. Circulation Pump 9 19
16. DHW Flow Sensor (Combi Models Only)
17. Water pressure switch 8
18. Modulating Fan 20
19. Boiler inlet temperature sensor 18
26
20. Frame 11
21. Ignition electrode 10
22. Spark generator 15
23. Combustion Analysis Test Point 12
13
24. Air intake connection
17
25. Exhaust vent connection
26. Diverter valve 16
You're in Control - Wherever You Are*
With HTP Link, you and trusted service personnel can:
• Remotely view boiler parameters and status,
ensuring proper operation and maximum
efficiency.
• Receive boiler text and e-mail updates, alerting
service personnel of possible issues.
• Access the boiler and troubleshoot issues without
having to be onsite, reducing costly service calls.
ELU-150 - 199 Boiler and
199 Combi Model Shown
ELU-150 - 199 Boiler and 199 Combi
Floor Mount ("FLK") Model Shown *HTP Link Available on All Models
17Specifications - ELU-150 - 199K BTU Combi/Boiler
Model ELU-150WBN ELU-150WBNFLK ELU-199WBN ELU-199WBNFLK ELU-199WCN ELU-199WCNFLK
Type Boiler Combi
Installation Indoor, Wall Hung, Fully Condensing
NG 19,700 / 197,000 NG 19,700 / 197,000
Minimum / Maximum Input (Btu/Hr)1 15,000 / 150,000
LP 19,200 / 192,000 LP 19,200 / 192,000
DOE AFUE2 (%) 95 95 95
Heating Capacity1, 2 (MBH) 139 184 184
Net AHRI Rating, Water (MBH)2 121 160 160
35oF Rise N/A N/A 10.5
Hot Water Capacity 45oF Rise N/A N/A 8.2
77oF Rise N/A N/A 4.8
Flue System Category IV, Sealed Combustion Direct Vent, Power Vent
Minimum - Maximum Exhaust Vent Run3 2” (6 - 100 feet) / 3” (6 - 150 feet) 3” (6 - 150 feet)
Minimum - Maximum Intake Air Pipe Run3 2” (0 - 100 feet) / 3” (0 - 150 feet) 3” (0 - 150 feet)
Approved Exhaust Vent Materials3 PVC, CPVC, PP, Stainless Steel
Shipping Weight (lbs) 115 150 125 160 130 165
Gas Supply NG 3.5” to 10.5” WC
Pressure LP 8” to 13” WC
Power Supply 120V, 60 Hz, less than 12A
ELU
Ambient Temperature Range: 33 – 104oF (0.6 – 40oC)
General Operating Conditions
Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9
Ignition System Direct Electronic Spark Ignition / Flame Rectification
ELU
ELU ELU
Burner System Premixed Fuel Modulation / Stainless Steel Burner
Gas Valve System Air Ratio Valve
Residential Residential Condens
Condensing Gas Boiler
W 19.75” 21.65" 19.75” 21.65" 19.75” 21.65"
Dimensions
H 38.25” 50.97" 38.25” 50.97" 38.25” 50.97"
(in Inches)
D Installation 18.5” 20.09"
ResidentialInstallation
Residential Condensing
Condensing18.5”
Residential
Gas
GasBoiler
Condensing
Boiler 20.09"
Gas Boiler 20.09" 18.5”
Approx. Full Boiler Weight (lbs) 115 150 130 165 135 170
Boiler Water Content (Gallons) Commissioning
2 Commissioning2.7
Boiler Setpoint Temperature Range Installation
Installation Installation
68 – 122oF Low Temperature / 86 - 179oF High Temperature
o
DHW Indirect Setpoint Temperature Range 104 – 149 F
Maintenance Maintenance
DHW Setpoint Range (CombiCommissioning
Commissioning
Models) Commissioning o
97 – 140 F
Heat Exchanger MAWP 50
Water Pressure Parts
Pressure Relief Valve
Parts30
(PSI) Maintenance
Maintenance Maintenance
DHW Max Pressure N/A N/A 150
Control Panel / Main Controller Warranty Warranty
AristonThermo LCD Display / AristonThermo GALEVO2 Control
Parts
Parts
CH Supply / Return
Parts 1 1/4” Male NPT
Connection
DHW Inlet / Outlet 3/4” Male NPT
Sizes
Warranty
Warranty
Gas Inlet Warranty 3/4” Male NPT
Cabinet Painted and Galvanized Steel
Materials
Heat Exchanger Type 441 Stainless Steel Water Tube
Flame Rectifier Probe, Temperature Limit Control (190oF), Water Pressure Switch (Min. 8 PSI), Freeze Protection,
Safety Devices
Condensate Trap, Flue Temperature High Limit Sensor (210oF)
DANGER DANGER
Table 2 - Technical Specifications
NOTES:
1 Read all instructions in this manual before installing. Perform steps inRead all instructions in this manual before installing. P
the given
Listed Input and Output Ratings are at minimum vent lengths at an altitude of 0 - 2000 ft. Numbers will be lower with longer venting and/or altitudes greater than 2000 ft.
2 order.personal
order. Failure to do so could result in substantial property damage, severe Failure to do so could result in substantial prope
Ratings based on standard test procedures prescribed by the US Department of Energy. injury, or death.
3 injury, or death.
The ELU requires a special venting system. Use only the vent materials and methods detailed
DANGER
DANGER in these installation instructions.
DANGER
WARNING WARNING
Read
Readall
order.
allinstructions
instructions
order.Failure
ininthis
Improper
Failuretotoproduct
do
doso
this
socould
could
manual
manualbefore
installation,
result
result
warranty
before
adjustment,
ininsubstantial
and order.
substantial
cause
15 Year Limited Warranty
Readinstalling.
all
installing.
instructions
Failure
Perform
Perform
property
property
property
in service,
alteration,
todamage,
do so
this
steps
damage,
steps
damage,
could
manual
ininorthe
result
severe
severesevere
thebefore
given
given installing.
maintenance
inpersonal
substantial
personal
personal
couldPerform
Improper
orproperty
injury,product
death.
steps inadjustment,
installation,
void
damage,
warranty
the given alteration, service, o
andsevere
causepersonal
property damage, severe
injury,
injury,orordeath.
death.California Proposition 65 injury, or death.
Warning: This product contains chemicals known California Proposition 65 Warning: This product contain
to the
State of California to cause cancer, birth defects, or other reproductive State
harm.of California to cause cancer, birth defects, or oth
WARNING
WARNING WARNING
In accordance with our company policy of ongoing product improvement, HTP reserves the right to make changes without prior notice. • Preliminary product specifications
NOTICE NOTICE
Improper
Improperinstallation,
installation,adjustment,
adjustment,alteration,
alteration,
Improper service,
service,
installation,
orormaintenance
maintenance
adjustment, could
could
alteration,
void
void service, or maintenance could void
product
productwarranty
warranty and
Theand cause
causeproperty
property
manufacturer damage,
product
damage,
reserves thewarranty
severe
severe
right topersonal
personal
and cause
make injury,
injury,
property
product orordeath.
death.
changes damage, severe
or updates personal injury,
The manufacturer
without or death.
reserves the right to make product c
18 California
CaliforniaProposition
Proposition
notice 6565Warning:
and Warning: This
will not beThis
California
product
heldproduct
liablecontains
Proposition
contains
for chemicals
chemicals
65 Warning:
typographical known
known
errors This
in totoproduct
the
the notice
literature. contains
andchemicals
will not beknown to thefor typographical erro
held liable
State
StateofofCalifornia
Californiatotocause
causecancer,
cancer,birth
birth
State
defects,
defects,
of California
ororother
othertoreproductive
reproductive
cause cancer, harm.
harm.
birth defects, or other reproductive harm.
The surfaces of these products contacted by potable (consumable) waterThe surfaces
contain less of these products contacted by potable (conFire Tube
ULTRA
Highly Efficient Condensing Boiler & Combi Units
®
Features
DURABLE HEATING - BOILER & COMBI UNITS
Boiler Firing Rates: 85,000, 110,000, 150,000, 199,000 Btuh
Combi Firing Rates: 110,000, 150,000, 199,000 Btuh
Vertical down fired Stainless Steel Heat Exchanger for exceptional efficiency,
low pressure drop, and durable performance
ABSOLUTE EFFICIENCY
Up to 96% AFUE while using an outdoor sensor (included)
10:1 turndown ratio limits short cycling and provides more efficient energy
consumption
Built-in automatic bypass eliminates expensive primary / secondary piping
Equipped with a built-in highly efficient ECM Pump
WHISPER QUIET OPERATION
Thanks to a pump and combustion fan with insulating panels
EASY TO USE INTERFACE
LCD display with digits, symbols, and an intuitive menu to easily set the de-
sired temperature, activate functions, and manage different heating zones
COMBI BOILER: FULL COMFORT SETTING
Domestic hot water preheat function for instant hot water
SMART CONNECTIVITY WITH HTP LINK
The Elite Ultra boiler is always at your fingertips with a WiFi gateway on board, allowing the boiler and its many system
parameters to be monitored remotely
Set up real-time service notifications and maintenance alerts to ensure that the unit is regularly monitored, overdue for main-
tenance, or if professional assistance is recommended
EASY TO SERVICE WITH QUICK SNAP COMPONENT AND SENSOR CONNECTIONS
ASSE 1017 & 1070 CERTIFED THERMOSTATIC MIXING VALVE INCLUDED WITH COMBI UNITS
FIFTEEN (15) YEAR LIMITED WARRANTY
19A Look Inside the EFTU-85 - 199K BTU Combi/Boiler
24
25
1. Pressure relief valve 1
2. Air purge valve
3. Boiler outlet temperature sensor 23
4. Air pressure switch
22 2
5. Flue gas temperature sensor
6. Main heat exchanger 18
7. Flame detection electrode 7 5
8 Silencer
21 4
9. Junction box
10. DHW Heat Exchanger (Combi Models
Only) 3
12
11. Condensate trap
8
12. Gas valve
13. Control panel 20
15. Circulation Pump 6
16. DHW Flow Sensor (Combi Models Only)
17. Water pressure switch 9
18. Modulating Fan
19. Boiler inlet temperature sensor
20. Frame 19
21. Ignition electrode 26
22. Spark generator 15
10
23. Combustion Analysis Test Point
11
24. Air intake connection
25. Exhaust vent connection 13 17
26. Diverter valve
16
Vertical Fire Tube Heat
Exchanger
• Features robust SA-240 S43932 Chro-
mium stainless steel
• Down-Fired design resists combustion
chamber fouling better than other heat Up to
96
exchanger types
• Resists scale build-up and magnetite
formation, increasing heat exchanger
life and reducing maintenance
• Innovative dimpled tubes extract more
heat while remaining compact, without
the need for inserts that degrade over
time
20Specifications
Model EFTU-85WBN EFTU-110WBN EFTU-150WBN EFTU-199WBN EFTU-110WCN EFTU-150WCN EFTU-199WCN
Type Boiler Boiler Boiler Boiler Combi Combi Combi
Installation Indoor, Wall Hung, Fully Condensing
8,500 / 11,000 / 15,000 / 19,900 / 11,000 / 15,000 / 19,900 /
Minimum / Maximum Input (Btu/Hr)1
85,000 110,000 150,000 199,000 110,000 150,000 199,000
DOE AFUE2 (%) 96 95 95 95 95 95 95
Heating Capacity1, 2 (MBH) 79 101 138 184 101 138 184
Net AHRI Rating, Water (MBH)2 69 88 120 160 88 120 160
35oF Rise 5.8 7.9 10.5
Hot Water Capa-
45oF Rise N/A N/A N/A N/A 4.5 6.1 8.2
city
77oF Rise 2.6 3.6 4.8
Flue System Category IV, Sealed Combustion Direct Vent, Power Vent
Minimum - Maximum Exhaust Vent Run3 2” (6 - 100 feet), 3” (6 - 150 feet) 3” (6 - 150 feet) 2” (6 - 100 feet), 3” (6 - 150 feet) 3” (6 - 150 feet)
Minimum - Maximum Intake Air Pipe Run3 2” (0 - 100 feet), 3” (0 - 150 feet) 3” (0 - 150 feet) 2” (0 - 100 feet), 3” (0 - 150 feet) 3” (0 - 150 feet)
Approved Exhaust Vent Materials3 PVC, CPVC, PP, Stainless Steel
Shipping Weight (lbs) 110 110 120 131 110 121 132
Gas Supply NG 3.5” to 10.5” WC
Pressure LP 8” to 13” WC
Power Supply 120V, 60 Hz, less than 12A
Ambient Temperature Range: 33 – 104oF (0.6 – 40oC)
General Operating Conditions
ELU
Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9
Ignition System Direct Electronic Spark Ignition / Flame Rectification
Burner System Premixed Fuel Modulation / Stainless Steel Burner
Gas Valve System Air Ratio Valve
ELU
ELU ELU
W 19.75
Dimensions
H
Residential
38.25
Residential Condens
Condensing Gas Boiler
(in Inches)
D 17 18.5 17 18.5
Approx. Full Boiler Weight (lbs) 107 107 122 139.5 107 128.5 140.5
Installation Residential
Residential Installation
Condensing
Condensing
Residential
Gas
Gas Boiler
Condensing
Boiler2.1 Gas 2.8
Boiler
Boiler Water Content (Gallons) 1.4 1.4 2.0 2.8 1.5
Boiler Setpoint Temperature Range 68 – 122oF Low Temperature / 86 - 179oF High Temperature
DHW Indirect Setpoint Temperature
Commissioning Commissioning
Range Installation
Installation Installation 104 – 149oF
DHW Setpoint Range (Combi Models) Maintenance Maintenance
97 – 149oF
Commissioning
Commissioning
Heat Exchanger MAWP Commissioning 50
Water Pressure
Pressure Relief Valve 30
(PSI)
DHW Max Pressure
Parts Parts
Maintenance
Maintenance
N/A
Maintenance
N/A N/A N/A 150 150 150
Control Panel / Main Controller AristonThermo LCD Display / AristonThermo GALEVO2 Control
CH Supply / Return Warranty Warranty
1 1/4” Male NPT
Connection Parts
Parts
DHW Inlet / Outlet
Parts 3/4” Male NPT
Sizes
Gas Inlet 3/4” Male NPT
Materials
Cabinet Warranty
Warranty Warranty Painted Steel
Heat Exchanger SA-240-S43932 Stainless Steel Water Tube
Flame Rectifier Probe, Temperature Limit Control (190oF), Water Pressure Switch (Min. 8 PSI), Freeze Protection,
Safety Devices Blocked Condensate Pressure Switch, Condensate Trap, Flue Temperature High Limit Sensor (210oF), Blocked
Vent Pressure Switch
Table 3 - Technical Specifications DANGER DANGER
NOTES:
1
Listed Input and Output Ratings are at minimum vent lengths at an altitude of 0 - 2000 ft. Numbers will be lower
Read all instructions with
in this longer
manual venting
before and/or
installing. altitudes
Perform steps ingreater
Read than 2000 in
all instructions
the given ft.this manual before installing. P
2
Ratings based on standard test procedures prescribed by the US Department of Energy. order. Failure to do so could result in substantial property damage, order.personal
severe Failure to do so could result in substantial prope
3
The EFTUrequires a special venting system. Use only the vent materials and methods detailed in these
injury, installation instructions.
or death. injury, or death.
DANGER
DANGER DANGER
WARNING WARNING
Read
Readall
order.
allinstructions
instructions
order.Failure
ininthis
Improper
Failuretotoproduct
do
doso
this
socould
could
manual
manualbefore
installation,
result
result
warranty
before
adjustment,
ininsubstantial
and order.
substantial
cause
15 Year Limited Warranty
Readinstalling.
all
installing.
instructions
Failure
Perform
Perform
property
propertyproperty
in service,
alteration,
todamage,
do so
this
steps
damage,
steps
damage,
could
manual
ininorthe
result
severe
severesevere
thebefore
given
given installing.
maintenance
inpersonal
substantial
personal
personal
couldPerform
Improper
orproperty
injury,product
death.
steps inadjustment,
installation,
void
damage,
warranty
the given alteration, service, o
andsevere
causepersonal
property damage, severe p
injury,
injury,orordeath.
death.California Proposition 65 injury, or death.
Warning: This product contains chemicals known California Proposition 65 Warning: This product contain
to the
State of California to cause cancer, birth defects, or other reproductive State
harm.of California to cause cancer, birth defects, or oth
WARNING
WARNING WARNING
In accordance with our company policy of ongoing product improvement, HTP reserves the right to make changes without prior notice. • Preliminary product NOTICEspecifications
NOTICE
Improper
Improperinstallation,
installation,adjustment,
adjustment,alteration,
alteration,
Improper service,
service,
installation,
orormaintenance
maintenance
adjustment, could
could
alteration,
void
void service, or maintenance could void
product
productwarranty
warranty and
Theand cause
causeproperty
property
manufacturer damage,
product
damage,
reserves thewarranty
severe
severe
right topersonal
personal
and cause
make injury,
injury,
property
product orordeath.
death.
changes damage, severe
or updates personal injury,
The manufacturer
without or death.
reserves the right to make product c 21
California
CaliforniaProposition
Proposition
notice 6565Warning:
and Warning: This
will not beThis
California
product
heldproduct
liablecontains
Proposition
contains
for chemicals
chemicals
65 Warning:
typographical known
known
errors This
in totoproduct
the
the notice
literature. contains
andchemicals
will not beknown to thefor typographical error
held liable
State
StateofofCalifornia
Californiatotocause
causecancer,
cancer,birth
birth
State
defects,
defects,
of California
ororother
othertoreproductive
reproductive
cause cancer, harm.
harm.
birth defects, or other reproductive harm.Phoenix Plus ®
High Efficiency Stainless Steel
Indoor / Outdoor Gas Fired Water Heater
Super Durable
10:1
• 316 L stainless steel tank,
(lightweight) longer service life
Up to • Heavy duty outdoor enclosure protects
the internal components including
Turndown Ratio the built-in condensate trap
• 2 hybrid cupronickel / stainless
steel heat exchangers *
4 Btuh Sizes • 119 gallon storage: reduced
cycling, adds to component life
• No additional storage tanks needed
199K * • 260 K
Super Efficient
320 K • 399K • Up to 95% thermal efficiency
• Best 1st hour output and recovery
• Load-matching modulation
• Up to 10:1 turndown ratio:
Built-in Redundancy (The 199K model has a 5:1 turndown ratio)
modulates down to 10% of input
(Dual Combustion System) capacity optimizes energy and
reduces cycling, increasing efficiency
Small Footprint • Recirculation port on the top section
provides additional efficiency
Indoor / Outdoor • Controls can be adjusted to increase
efficiency by staging each
Installation combustion system *
• Low NOx combustion system meets
the most stringent standards
• Power vent or direct vent options
TP Ma
•H d
a
eI
n Amer i c
n Amer i c
eI
a
SCAQMD Rule 1146.2
• HT Mad
P
*PHP199-119: features one control panel and one combustion system; cannot be staged; 199K Model: 5:1 turndown ratio
22 htproducts.com/phoenixplusSpecifications
HOT OUTLET
STANDARD FEATURES WHAT’S IN THE BOX HOT OUTLET
- Up to 95% Thermal Efficiency - Brass Tee and Bushing
- 2 Modulating Burners - Up to 10 :1 Turndown Ratio - Temperature and Pressure Relief Valve
(PHP199-199: 1 Burner; 199K model: 5:1 Turndown Ratio) - Installation Manual & Warranty
- Vents in PVC, CPVC, Stainless Steel, ULC S636 - LP Conversion Kit (Natural Gas Models Only)
- Spark ignition OPTIONAL EQUIPMENT
- Dual flame monitoring (Spark & Flame probe) - 3” PVC Concentric Vent Kit
- Flame stabilization monitoring (for the PHP199-199 Model)
- Integrated Control System INTAKE EXHAUST
24.4”
- 3”& 4” Stainless Steel Outside
INTAKE EXHAUST
24.4”
5.5”
- Pressure relief pre-piped Termination Vent Kits
5.5”
- Built-in low water cut-off probe - Condensate Neutralizer
- Limited 3 Year Commercial Warranty - Condensate Pump
- PC Connection Cable w/ Software
21”
21”
38” 32”
38” 32”
AUXILLARY
85” (77” for the PHP199-199)
AUXILLARY
85” (77” for the PHP199-199)
(RECIRC PORT)
(RECIRC PORT)
ELECTRICAL
ELECTRICAL
58.75” (49” for the PHP199-199)
58.75” (49” for the PHP199-199)
GAS
GAS
42.125”
42.125”
COLD INLET
COLD INLET
CONDENSATE
CONDENSATE
9.75”
9.75”
GPH at First # of
Btuh Input Air Gas Gallon Inlet/ Relief Shipping Thermal
Model Aux 100˚ F Hour Combustion
Modulation Intake Line Capacity Outlet Valve Weight Efficiency
Rise Rating Systems
PHP199-119 40k – 199k Btuh 3” 475 LBS 232 315 1 95%
PHP260-119 35k – 260k Btuh ¾” 119 1 ½” NPT 1” NPT 1” NPT 555 LBS 303 386 2 94%
4”
PHP320-119 40k – 320k Btuh 575 LBS 372 455 2 94%
PHP399-119 40k – 399k Btuh 575 LBS 464 574 2 95%
23The Phoenix ®
316 L Stainless Steel Tank
Super Durable: Super Efficient:
• 316L stainless steel tank • up to 96% efficiency
• Hybrid cupronickel /stainless • Load-matching modulation
steel heat exchanger • Outdoor sensor auto adjusts
• Reduced cycling adds for maximum efficiency
to component life • 2” foam insulation
• Venting: PVC/ CPVC • up to ½°F/hr standby loss
• 5:1 turndown ratio
Power vent or direct power vent options
Sanitizer Options Available
Phoenix Sanitizer: The Phoenix line offers a high temp sanitation tank for those
need to be clean applications. Great for use in restaurants, breweries, wineries,
dairies and more.
Up to 96% Efficient
PHOENIX WATER HEATER AND SANITIZER BOOSTER SPECIFICATIONS
Btuh Recovery at Gallon Inlet/ Shipping
MODEL
(w/ Mod) 100 0 F. Rise Capacity Outlet Size Weight
PH100-55 35,000 - 100,000 115 55 1” NPT 175 LBS
PH130-55 35,000 - 130,000 148 55 1” NPT 175 LBS
PH160-55 40,000 - 160,000 184 55 1” NPT 175 LBS
PH199-55 40,000 - 199,000 229 55 1” NPT 175 LBS
PH100-80 35,000 - 100,000 116 80 1.5” NPT 235 LBS
PH130-80 35,000 - 130,000 150 80 1.5” NPT 235 LBS
PH160-80 40,000 - 160,000 184 80 1.5” NPT 235 LBS
PH199-80 40,000 - 199,000 229 80 1.5” NPT 235 LBS
PH100-119 35,000 - 100,000 117 119 1.5” NPT 405 LBS
PH130-119 35,000 - 130,000 152 119 1.5” NPT 405 LBS
PH160-119 40,000 - 160,000 184 119 1.5” NPT 405 LBS
PH199-119 40,000 - 199,000 230 119 1.5” NPT 405 LBS
PH199-55SA (184 F) 40,000 - 199,000 229 55 1” NPT 175 LBS
Note: All units are compatible with natural gas or liquid propane, but must be specified upon
placing an order.
24 htproducts.com/phoenixThe Phoenix Dimensions & Specifications
LEFT SIDE FRONT VIEW AUX. CONNECTION
AUX. CONNECTION
q h f g s
q ?
h r
f h
g c
s d
? r h c d
TEMP/PRESSURE
TEMP/PRESSURE
RELIEF VALVE
RELIEF VALVE
L L
B B J
Outdoor Sensor J
C C Auto Adjusts
for Maximum
Efficiency
M M
F F
E E
Combining the Phoenix with an Air Handler
G
D D A A H
G
H
A Unique and Highly
K Efficient
K
Way to Provide Heat and Hot Water
LOW WATER
HTP ’s Unique Design
LEFT SIDE LEFT SIDE LOW WATER FRONT VIEWFRONT VIEW
CUT-OFFCUT-OFF
HOT WATER
HOT WATER
OUTLET OUTLET
Our laser welded, stainless steel tank is the best in the industry and will outlast any glass-lined tank.
This light weight tank is built to last! The Phoenix has a 5:1 turndown ratio this reduces cycling and in-
HIGH LIMIT
HIGH LIMIT
creases efficiency. The Phoenix is up to 96% efficient! The heat exchanger is a Stainless Steel / Cupronickel
SAFETY SAFETY
UPPER TEMP
UPPER TEMP
spiral design that
SENSORexpands
SENSOR and contracts
AIR AIR rapidly with the change in temperature, eliminating scale build-up
INTAKE INTAKE
B
(self-cleaning).
B
C C J J
GAS GAS L
LINE L
PHOENIX WATER HEATER AND
LINE SANITIZER BOOSTER DIMENSIONS
M MSTANDARD FEATURES
- Up to 96% Thermal Efficiency
MODEL GAL. E AE B C D E F G H - Modulating Burner
F F
LOWER LOWER 5:1 Turndown Ratio
PH100-55 / PH130-55 TEMP TEMP G - Vents in PVC, CPVC, Stainless Steel,
SENSOR SENSOR 55 23” G 52” 45” 5” 14-3/4” 16-1/4” 5-1/4” 1”
PH160-55 / PH199-55 H H ULC S636
- Limited Warranty
7 Year Residential
PH100-80 / PH130-80
80 23” 72” 64” 5” N 17” 18-1/2” 7-3/4” 3-1/4” 3 Year (5 Year Option Available )
D PH160-80
D
/APH199-80
A O
N K K Commercial
EXHAUSTEXHAUST O
VENT VENT HEAT EXCHANGER
HEAT EXCHANGER
COLD WATER
COLD WATER/
PH100-119 PH130-119 WHAT’S IN THE BOX
INLET CONDENSATE LINE HOT OUTLET
HOT OUTLET
INLET 119 CONDENSATE
27” LINE74” 66-1/4” 7-1/2” 18-3/4” 21-1/2” 10-1/2” 5” - Intake PVC Tee w/ Screens
PH160-119 / PH199-119 HEAT EXCHANGER
HEAT EXCHANGER - Exhaust PVC Coupling w/ Screens
COLD INLET
COLD INLET - Installation Manual
PH199-55SA (Sanitizer) 55 23” 52” 45” 5” 14-3/4” 16-1/4” 5-1/4” 1” - LP Conversion Kit (Natural Gas Models Only)
OPTIONAL EQUIPMENT
- Outdoor Sensor
PHOENIX WATER HEATER AND SANITIZER BOOSTER SPECIFICATIONS - 2”, 3” PVC Concentric Vent Kit
- 3”, 4” Stainless Steel Outside
Air Intake/ Inlet/ Auxiliary Gas Line System Shipping Max. Temp Termination Vent Kit
MODEL Btuh T. Efficiency / UEF - Condensate Neutralizer
Exhaust Vent Outlet Conn. Conn. Relief Pipe Weight Limit
- PC Connection Cable w/ Software
PH100-55 100,000 2” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 160 F .89 - Sanitizer Booster Kit
PH130-55 130,000 2” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 160 F 94%
PH160-55 160,000 3” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 160 F 95%
PH199-55 199,000 3” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 160 F 95% TP Ma
•H d
a
PH100-80 100,000 2” 1-1/2” NPT 1” FNPT 3/4” 3/4” 235 LBS 160 F .93
eI
n Amer i c
n Amer i c
PH130-80 130,000 2” 1-1/2” NPT 1” FNPT 3/4” 3/4” 235 LBS 160 F 95%
eI
a
• HT Mad
P
PH160-80 160,000 3” 1-1/2” NPT 1” FNPT 3/4” 3/4” 235 LBS 160 F 96%
PH199-80 199,000 3” 1-1/2” NPT 1” FNPT 3/4” 3/4” 235 LBS 160 F 95%
PH100-119 100,000 2” 1-1/2” NPT 1” FNPT 3/4” 3/4” 405 LBS 160 F .90
PH130-119 130,000 2” 1-1/2” NPT 1” FNPT 3/4” 3/4” 405 LBS 160 F 96% SCAQMD Rule 1146.2
PH160-119 160,000 3” 1-1/2” NPT 1” FNPT 3/4” 3/4” 405 LBS 160 F 96%
PH199-119 199,000 3” 1-1/2” NPT 1” FNPT 3/4” 3/4” 405 LBS 160 F 96%
PH199-55SA 199,000 3” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 184 F 95%