Meeting Various Needs with

Meeting Various Needs with

Meeting Various Needs with

The colors may be different from the actual colors because this catalog is printed matter. Product specifications are subject to change without notice. Distributed by : “ ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan and other countries or areas. *Echelon®, LONWORKS®, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. *BACnet® is a registered trademark of the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE). 6NNJ24-1212E 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ Copyright© 2011 Fujitsu General Limited.

All rights reserved. Fujitsu General (Thailand) Co., Ltd.

ISO 9001 Certified number : 01 100 89394 ISO 14001 Certified number : 01 104 9245101 Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd. ISO 9001 Certified number : 00608Q11061R2M ISO 14001 Certified number : 00609E20454R2M Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE Series Fujitsu General (Shanghai) Co., Ltd. ISO 9001 Certified number : 01 100 79269 ISO 14001 Certified number : 310102-UK

Meeting Various Needs with

INDOOR UNITS CONTROLLERS Compact Cassette High Static Pressure Duct Cassette Floor / Ceiling Low Static Pressure Duct Ceiling Slim Duct (Drain Pump internal) Wall Mounted (EEV internal / EEV external) Medium Static Pressure Duct Wall Mounted Group Remote Controller Touch Panel Controller Wired Remote Controller Wired Remote Controller (Touch Panel) Simple Remote Controller Wireless Remote Controller System Controller (Software) Central Remote Controller The AIRSTAGE J-II Series adopts the best technology and was designed with the greatest care to provide not only energy savings and comfort but also ease of design, installation, and maintenance.

Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. Large Homes Central Controller Individual Controller Building owners End users Installers Service and Management companies Various Line-up for each buildings Small Office OU UTDOOR UNITS 4HP 5HP 6HP AJ*A40LALH AJ*A45LALH AJ*A54LALH AJ* : AJY (FUJITSU), AJH (GENERAL) Wide lineup of indoor units and controllers to support a variety of properties. 02 03

Meeting Various Needs with

The building load is the range of almost 40 % to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because all the air conditioners do not always operate all the time. Aiming at energy saving performance matched to actual operation, Fujitsu General has developed a high intermediate performance air conditioner corresponding not only to the rated performance at 100% load, but also to low to medium load High EER / COP High part load performance (6HP class) Efficiency in actual operation Load curve (a typical office building) Compressor efficiency High High Compressor capacity DC Twin Rotary compressor 4 HP 5 HP Conditions : Connected indoor units: AUXA30GALH+AUXD24GALH Cooling : indoor temp.

of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWB Heating : indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB 6 HP 4.29 3.72 4.20 3.60 3.95 3.45 5.75 COP Heating part load EER Cooling part load 5.73 100% 3.95 50% 100% 3.45 50% : COP : EER 66% UP 46% UP 20 40 60 80 100 3 6 9 12 Time (h) 15 18 21 24 Building load (%) Highly accurate parts Optimized refrigerant flow design High efficiency compressor motor DC twin rotary compressor Efficiency in all load regions is good. Especially good performance from low to medium at normal operation.

Large propeller fan High performance and low noise realized by large propeller and optimization of angle. DC inverter control Efficiency is improved by mounting of new active filter module. Subcool heat exchanger Cooling performance is improved by mounting of dual tube heat exchanger. DC fan motor Miniaturized, low noise, high efficiency, multi-stage DC fan motor is mounted. Large heat exchanger Heat exchange performance is substantially improved by mounting of 3-row large heat exchanger. Pressure Enthalpy effect Cooling performance improved 04 05 FEATURES High Energy Saving

Meeting Various Needs with

Auto Off function Able to prevent wastage of energy.

Current model Function setting is required. 1 indoor unit (Master) can apply this function. ON OFF Operation stopped at oil recovery Time Time ON J-II series Set Temp. Temp. (°C) Noise level Time (4~6HP) Heating Cooling Original Set Temp. Set point limitation setting Central Remote Controller 30 28 26 24 22 20 18 16 14 12 10 Cooling Set Temperature Economy operation Control Temperature Heating Set Temperature Economy operation Control Temperature Set Temp. MAX. -4°C MAX. +2°C Economy operation Up Up Economy operation Set Temp.

Down Down Down Down Capacity Time Setting level 18:00 20:00 22:00 OFF OFF OFF Low Noise Design Various Comfort Control Function Wasteful Operation is Prevented. Heating capacity is improved at low outdoor temperature by our advanced technology. Low noise design of outdoor unit Significantly reduced noise by optimized airflow structure design of outdoor unit. Operation Performance is Efficiently Controlled. Powerful Heating Room temperature set point limitation The minimum and maximum temperature range can be set. Economy operation The temperature setting is offset automatically over a certain period of time.

Capacity save operation The power consumption at peak can be limited. Low noise mode Outdoor unit can be switched to silent mode, depending on the installation environment. Easy auto changeover function At the auto mode, cooling and heating mode is switched automatically to maintain the setting temperature. Non-stop oil recovery operation The product continues to operate without stopping the cooling or heating operation during oil recovery modes. Auto louver grill (Option for Slim Duct) Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet Rated noise value -5dB~-6dB Capacity save Setting range 100% 80% 60% 40% 0% 56dB 53dB Current model J-II series 6HP class (Cooling) Low noise mode Heating operation Heating operation 33% UP! (°C) Cooling operation 7 Current model (6HP class) 16.6 Heating capacity (kW) J-II series (6HP) Outdoor temperature (°C) Current model (6HP class) -20 -10 0 With Auto Louver 40 30 15 20 25 35 Temperature(°C) 06 07 FEATURES More Comfort Various Energy Saving Function

Meeting Various Needs with

Group Remote Controller UTY-CGG* • Max. controllable 18 indoor units Central Control of Small Office, Shop, etc. Individual and Central Control of Large Homes Control system composition example Control system composition example BACnet® Gateway (Software) Network Convertor for LONWORKS® System Controller (Software) Central Remote Controller or Group Remote Controller Building control computer Wireless Remote Controller Wired Remote Controller + Wireless Remote Controller IR Receiver Unit + Wireless Remote Controller Simple Remote Controller Wired Remote Controller + Simple Remote Controller Wired Remote Controller Central Remote Controller UTY-DCG* or • Automatic display of number of connected indoor unit • Max.

controllable 100 units Simple Remote Controller Wired Remote Controller UTY-RNK* With operation mode UTY-RSK* Without operation mode UTY-RHK* System Controller (Software) UTY-APGX Max. controllable 1,600 indoor units Convertor for BMS Control Building Management System BACnet® Gateway (Software) UTY-ABGX Network Convertor for LONWORKS® UTY-VLGX Network Convertor UTY-VGGXZ1 Security system Ventilation system Lighting facilities A/C central controller Group Remote Controller UTY-CGG* Max. controllable 18 indoor units Central Remote Controller UTY-DCG* Max. controllable 100 indoor units Touch Panel Controller UTY-DTG* Max.

controllable 400 indoor units G*: GY (FUJITSU), GG (GENERAL) R*: RY (FUJITSU), RG (GENERAL) K*: KY (FUJITSU), KG (GENERAL) H*: HY (FUJITSU), HG (GENERAL) G*: GY (FUJITSU), GG (GENERAL) VRF network system or Central Remote Controller Touch Panel Controller Network Convertor Group Remote Controller Wireless Remote Controller UTY-LNH* Wired Remote Controller (Touch Panel) UTY-RNR* 08 09 FEATURES More Convenience

Meeting Various Needs with

3 7 1 0 2 4 5 6 Long Piping Length Easier Installation High Capacity Connection Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design. Easy piping connection Improvement of the reliability by decreasing the flare connection. 180 m max. Height difference between indoor and indoor units 15 m max. Piping length from first separation tube to the farthest indoor unit 40 m max. Height difference between outdoor and indoor units 30 m max.

Actual piping length 120 m max. Total piping length Cooling Cooling 46°C 21°C -5°C -5°C -20°C -20°C Heating (°C) -20°C area Operation possible in heating.

50 40 30 20 10 -10 -20 Number of connectable indoor unit 4 HP 5HP 6 HP 2 to 7 units 2 to 8 units 2 to 9 units Wide operating range Installation in extreme temperature conditions is possible due to an increase in operational range. Cooling : -5°C~46°C Heating : -20°C~21°C Easy to connect with V-II communication system It is possible to connect directly with the transmission cable of the V-II system without convertor.

J-II system V-II system Connects without a converter Easy wiring connection • Decreasing wiring mistakes by using non-polar 2 wires.(Remote controller cable is 3 wires) • Improvement of wiring installation by common with V-II power supply method. Flexible installation of outdoor unit Corresponds to the outdoor unit concentration installation. Convenient Commissioning Support Automatic address setting function The address of each indoor unit can be automatically set by button switch of outdoor unit.

Connection check function Possible to confirm whether wiring connection and address setting are correct by check run function for a short time.

Reduced installation intervals by front access Flexible installation by 4 way pipe direction 12 types, 48 models Indoor unit Connectable indoor unit capacity range 130 % max. Press the push button of outdoor unit. • Display connected indoor unit numbers • Duplicately set address number of indoor unit can be displayed Flare connection Terminal box Flare connection EV kit J-II series Previous model Power supply cable Power supply (Indoor ) Power supply (Outdoor ) 10 11 FEATURES More Design Flexibility Easy Installation

Meeting Various Needs with

Emergency stop function Specifications Dimensions AJ* : AJY (FUJITSU), AJH (GENERAL) AJ* : AJY (FUJITSU), AJH (GENERAL) AJ*A40LALH / AJ*A45LALH / AJ*A54LALH Detail 650 970 32 12 370 Terminal blocks (Transmission) Terminal blocks (Power) 3-Way valve (Liquid) 3-Way valve (Gas) Ø 28 (C ab le po rt) Ø28 (Cable port) Pipe port Pipe port Pipe & cable port Pipe port 89 50 438 622 65 15 14 50 21 55 21 65 166 370 43(Liquid) 51(Gas) (410) 40 32 1334 907 297 (Gas valve) 279 50 95 120 50 50 25 87 131 (Liquid valve) ( ) 1000 111 70 155 142 21 227 305 341 154 36 Ø28 (Cable port) Ø28 (Cable port) Ø28 (Cable port) Ø28 (Cable port) A A Emergency Stop Function SU MO TU WE TH FR SA Wired Remote Controller Simple Remote Controller Error status can be checked easily via the indoor unit wired controller An error code is displayed on a liquid crystal screen.

Faulty unit number (Remote controller address) Error code Remote controller address Error code Design for Easy Maintenance Easy to read 7-segment LED Confirm detail operational and trouble status without using specific equipment Movable PCB panel Easier for maintenance work behind the PCB 7-segment LED Emergency alarm can be received by indoor, outdoor units, Central Remote Controller or Touch Panel Controller when they received it, all units will be stopped. Touch Panel Controller Central Remote Controller or Emergency stop function Emergency stop function T h P l Central Note : In case of received Emergency alarm by Indoor / outdoor unit : All units connected within same refrigerant system will be stopped.

Central Remote Controller or Touch Panel Controller : all units connected within VRF network system with Central Remote Controller or Touch Panel Controller will be stopped. (Unit : mm) Equipment Detail (Diagram) Trouble diagnosis by Service Tool Connection to Service Tool • Detail operation status and recent error history can be checked and analyzed by using Service Tool. • Last 5 min. operation memory can be also recorded. Transmission cable (Non-polar 2 wires) Service Tool UTY-ASGX USB adaptor (Field supplied) Software Capacity range HP Model name 4 5 6 AJ*A40LALH AJ*A45LALH AJ*A54LALH Power source Capacity kW kW W/W dB(A) mm Cooling Cooling Heating Dimensions (H×W×D) Heat exchanger fin COP EER Input power Sound pressure level Connection pipe diameter Weight mm kg kg 12.1 13.6 3.25 3.17 3.72 4.29 6,200 50 52 14.0 16.0 1,334 x 970 x 370 Blue fin 117 Max.connectable indoor unit*1 7 8 9 15.5 18.0 Heating 3.81 4.56 3.89 4.49 Cooling Heating Cooling Heating Air flow rate m3 /h 4.20 3.95 3.60 3.45 6,400 6,900 51 53 53 55 Refrigerant charge 4.8 5.3 9.52 15.88 19.05 Liquid Gas °CDB Operation temperature range Cooling Heating -5 to 46 -20 to 21 Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function might work when using it outside the operation range. 1Ø, ~ 230 V, 50Hz 12 13 FEATURES OUTDOOR UNITS Easy Maintenance

Meeting Various Needs with

14 15 INDOOR UNITS Indoor Unit Lineup Comprehensive range of indoor units of variety design and capacity ranges available which can be selected to suit any air conditioning needs. Cassette Duct Compact Cassette Cassette Slim Duct (Drain pump internal) Low Static Pressure Duct Medium Static Pressure Duct High Static Pressure Duct Floor Concealed Floor Slim Concealed Floor Ceiling Wall Mounted Wall Mounted (EEV external) Floor Ceiling Wall Mounted Capacity range (kW) Model code 2.2 7 2.8 9 3.6 12 4.5 14 5.6 18 7.1 24 11.2 36 9.0 30 14.0 54 AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXD18GALH ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH AS*E07GACH AS*E09GACH AS*E12GACH AS*E14GACH ARXB18GALH AS*A18GACH AB*A12GATH AB*A14GATH AB*A18GATH AB*A24GATH AUXD24GALH AUXB24GALH AUXA36GALH AUXA30GALH ARXA30GBLH ARXA24GBLH ARXA36GBLH ARXC36GATH AB*A30GATH AB*A36GATH AS*A07GACH AS*A09GACH AS*A12GACH AS*A14GACH AUXA54GALH AB*A54GATH 12.5 45 AUXA45GALH ARXA45GBLH ARXC45GATH AB*A45GATH AB*A12GATH AB*A14GATH AB*A18GATH AB*A24GATH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH AS*A30GACH AS*A24GACH 12 Types, 48 Models, Capacity range from 2.2kW to 14.0kW With this model, connection of EV kit is necessary.

AB* : ABY(FUJITSU), ABH(GENERAL) AS* : ASY(FUJITSU), ASH(GENERAL) ARXD24GALH ARXD18GALH ARXD07GALH ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH ARXD09GALH ARXD12GALH ARXD14GALH (*Same as Ceiling models) (*Same as Low Static Pressure Duct models) (*Same as Slim Duct models)

Meeting Various Needs with

A B C D Grille cover 2 1 3 Models: AUXB07 / AUXB09 / AUXB12 / AUXB14 / AUXB18 / AUXB24 Dimensions (Unit : mm) Adoption of laminar wing Spin direction Airflow direction Quiet Airflow runs through smoothly along the laminar wing No airflow separation Laminar wing Quiet High efficiency design by 2 stage structure Previous turbo fan Heat exchange efficiency 20%UP 1-stage 2-stage turbo fan + = 2-stage Designed by CFD-analysis (fluid) simulations Compact size panel design that fits standard ceiling panel (600x600mm) Models AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH 2-stage turbo fan Quiet quality Improvement of the airflow distribution Compact design High lift drain pump During installation, maintenance and operation, the drain pump and kit can be checked easily.

A : Fan motor C : Bell-mouth B : 2-stage turbo fan D : Panel 1 Maintenance of fan motor and fan 2 Long life filter : standard equipment 3 Adaptation of transparent drainage parts Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily.

Worlds first 24,000Btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size) Optimization of wing form (laminar wing type) and wing number (7 blades each) An evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams. In the case of a previous fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven. 07 09 12 14 18 24 Model code 2.7 2.7 2.7 2.7 2.7 2.7 Standard mode - - 3.0 3.0 3.0 3.0 High ceiling mode The maximum height from floor to ceiling (m) High ceiling mode The compact cassette can be installed up to a height of 3.0m (12/14/18/24).

570mm 570mm Fast Slow Wind velocity Ceiling panel Max. 700mm Optional parts Air Outlet Shutter Plate : Insulation Kit for High Humidity : Fresh Air Intake Kit : UTR-YDZB UTZ-KXGC UTZ-VXAA 2.2 2.8 25 540 450 350 34 30 25 AUXB07GALH AUXB09GALH AUXB12GALH AUXB18GALH AUXB14GALH Cooling Heating High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain 2.8 3.2 25 550 450 350 35 30 25 4.5 5.0 35 680 590 390 38 34 27 5.6 6.3 36 710 580 400 41 35 27 7.1 8.0 84 1,030 830 450 50 44 30 3.6 4.1 29 600 530 390 37 34 27 kW W m3/h dB(A) mm kg mm mm kg Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Cassette Grille F* : FY (FUJITSU) ; FG(GENERAL) Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 15 ø6.35 ø12.70 AUXB24GALH 245 x 570 x 570 UTG-UF*C-W 50 x 700 x 700 2.6 17 ø9.52 ø15.88 230V ~, 50Hz ø25 (I.D) ; ø32 (O.D.) Model name Dimensions (H x W x D) Weight Specifications Compact Cassette 16 17 INDOOR UNITS 285 285 Ceiling 114 114 700 700 IR receiver □ 570 : Indoor unit 370 540 Hanging bolt position □ 580 to 660 Ceiling openings 530 530 Hanging bolt position Drain hose 215 19 30 123 30 262 183 Control Box 146 40

Meeting Various Needs with

18 24 30 36 45 54 Model code 3.0 3.0 3.2 3.2 3.2 3.2 Standard mode 3.5 3.5 3.6 4.2 4.2 4.2 High ceiling mode The maximum height from floor to ceiling (m) Models: AUXD18 / AUXD24 (Slim type) AUXA30 / AUXA36 / AUXA45 / AUXA54 Dimensions (Unit : mm : AUXD18 / AUXD24 High efficiency turbo fan with 3-dimensional blade Detachable Grille corner Adjustment can be done just taking off the corner part Parallel apertures 450mm Heat exchanger < Motor side > Uneven airflow Separation phenomenon of airflow causes noise : Spin direction : Airflow direction : Turbulent flow noise < Motor side > Heat exchanger 3-dimensional blade High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger.

Previous blade 500mm No airflow separation Quiet Ceiling panel Improvement of the airflow distribution Adjustment of hanger position is possible after installation One way aperture installation High lift drain pump High ceiling mode The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution. This cassette can be installed up to a height of 4.2m (36/45/54). Much less temperature irregularity happens by spreading airflow widely Bottom view Front part Ceiling Rear part Round louvre Optional parts IR Receiver Unit : Air Outlet Shutter Plate : Panel Spacer : Insulation Kit for High Humidity : Wide Panel : Fresh Air Intake Kit : UTY-LRH*B1 UTR-YDZC UTG-BGYA-W UTZ-KXGA / UTZ-KXGB UTG-AGYA-W UTZ-VXGA H*: HY(FUJITSU), HG(GENERAL) Max.

850mm Powerful, wide airflow and quiet operation Models AUXD18GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH Previous turbo fan Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling. Fast Slow Wind velocity 5.6 6.3 39 1,150 940 870 36 30 29 Cooling Heating High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain kW W m3/h dB(A) mm mm mm kg kg Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Cassette Grille G* : GY(FUJITSU) ; GG(GENERAL) Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. AUXD18GALH 230V ~, 50Hz AUXD24GALH AUXA30GALH AUXA45GALH AUXA36GALH AUXA54GALH 246 x 840 x 840 22 288 x 840 x 840 27 ø9.52 ø25 (I.D.) ; ø32 (O.D.) UTG-UG*A-W 50 x 950 x 950 5.5 Model name Dimensions (H x W x D) Weight Specifications 9.0 10.0 59 1,600 1,300 1,100 40 38 33 11.2 12.5 80 1,800 1,300 1,100 44 38 33 14.0 16.0 119 2,000 1,370 1,100 47 39 33 7.1 8.0 46 1,280 1,040 870 38 33 29 ø15.88 12.5 14.0 99 1,900 1,370 1,100 46 39 33 ø19.05 Cassette 18 19 INDOOR UNITS 796 Hanging bolt position Drain hose 358 □ 840 : Indoor unit 607 420 699 Hanging bolt position □ 860 to 910 Ceiling opening 142 142 Ceiling 950 IR receiver (Option) 950 (Control Box 200 10 358 278 60 44 40 Wire hole Gas pipe Liquid pipe 140 298(256)

Max. 850mm Slim size (217mm) allows installation even where the space behind the ceiling is narrow. Compact design Refrigerant piping flare connection (Gas) Refrigerant piping flare connection (Liquid) Drain piping connection 2 1 3 Models: ARXB07 / ARXB09 / ARXB12 / ARXB14 / ARXB18 *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size. Two-direction drain piping Two-direction drain piping Duct indoor unit Filter (2pcs.) ARXB07 / ARXB09 ARXB12 / ARXB14 / ARXB18 Filter (3pcs.) Ultra-slim duct air conditioner for easy installation 2 1 3 Control box Brackets Brackets Airflow outlet Control box 886 (Bolt pitch) (Bolt pitch) (596) 850(560) 390 166 595 20 24 47 85 587 194 150 75 65 364 953 (663) 600 (400) 94 (50) 10 217 150 886 (596) 170 217 Small and compact indoor unit suitable for many applications Models ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH Refrigerant piping flare connection (Gas) Refrigerant piping flare connection (Liquid) Drain piping connection 2 1 3 Models: ARXB07 / ARXB09 / ARXB12 / ARXB14 / ARXB18 *Service accessibility must be allowed for when installing the product.

Please consult the installation manual for the necessary service access size. 2 1 3 Control box Brackets Brackets Airflow outlet Control box 886 (Bolt pitch) (Bolt pitch) (596) 850(560) 390 166 595 20 24 47 85 587 194 150 75 65 364 953 (663) 600 (400) 94 (50) 10 217 150 886 (596) 170 217 Dimensions (Unit : mm : AR7 / AR9 Air-intake Back side Bottom side Air intake direction can be selected to match the installation site. Height 217mm Flexible installation Floor concealed Ceiling concealed Filter (Accessory) ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH Concealed Floor Low noise level 7 9 0 to 50 27 Pa dB(A) Static pressure range Noise level (Low speed) 30 Model 24 25 30 12 14 18 A low noise level has been achieved for each capacity Static pressure (Pa) Low static pressure mode Normal mode Airflow drop prevention Low noise realized Airflow Optional parts Remote Sensor Unit : IR Receiver Unit : Drain Pump Unit : UTY-XSZX UTB-YWC UTZ-PX1BBA 2.2 2.8 46 370 310 280 0 to 50 25 29 26 24 ARXB07GALH ARXB09GALH ARXB12GALH ARXB18GALH ARXB14GALH Cooling Heating High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain 2.8 3.2 55 440 370 340 0 to 50 25 31 29 27 4.5 5.0 90 800 750 700 0 to 50 25 33 32 30 217 x 953 x 595 5.6 6.3 96 890 810 730 0 to 50 25 36 34 30 23 ø9.52 ø15.88 230V ~, 50Hz 3.6 4.0 63 590 500 450 0 to 50 25 30 28 25 ø25 (I.D.) ; ø32 (O.D.) kW W m3/h Pa dB(A) mm kg mm Model name Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter 217 x 663 x 595 15 22 ø6.35 ø12.70 Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.

Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Specifications Low Static Pressure Duct / Concealed Floor 20 21 INDOOR UNITS

Max. 850mm Dimensions (Unit : mm) Models: ARXD07 / ARXD09 / ARXD12 / ARXD14 / ARXD18 / ARXD24 *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size. ARXD07-14 ARXD18 ARXD24 700 A B C D E F G 900 1100 650 850 1050 734 934 1134 650 850 1050 P100x6=600 P100x8=800 P100x10=1000 18xØ5 22xØ5 26xØ5 574 774 974 (Bolt pitch) G 51 152 377 174 71 30 30 F (All surroundings) 82 48 E D C (Bolt pitch) 43 31 198 168 78 B A 10 69 144 264 367 620 47 55 78 89 119 163 Slim design and wide range of static pressure for flexible installation.

Models (Drain pump internal model) ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH Air-intake Air intake direction can be selected to match the installation site. Back side Bottom side Optional parts Remote Sensor Unit : IR Receiver Unit : Auto Louver Grille Kit : UTY-XSZX UTB-YWC UTD-GXSA-W (for ARXD07/09/12/14GALH) UTD-GXSB-W (for ARXD18GALH) UTD-GXSC-W (for ARXD24GALH) Slim design Drain port This model is slim design, it can install at the place where a ceiling is narrow. Drain pump built-in Height 198mm Drain pump Drain hose is standard accessory High lift drain pump Max.

850mm Filter (Accessory) Filter (2pcs.) ARXD07 / 09 / 12 / 14 / 18 ARXD24 Filter (3pcs.) Selectable with a wide range of static pressure By using DC fan motor, it is possible to change of static pressure range 0 to 90Pa. The change of static pressure range is possible by remote controller. *24 model is 0 to 50Pa Static pressure range 0 to 90 Pa Flexible installation Ceiling concealed Floor concealed Auto Louver Grille Kit (Option) Slim Duct Wired Remote Controller Wireles Remote Controller Auto Louver Grille Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.

Slim Concealed Floor ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH 2.2 2.8 44 550 490 440 0 to 90 25 28 25 22 ARXD07GALH ARXD09GALH ARXD12GALH ARXD18GALH ARXD14GALH Cooling Heating High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain Specifications 2.8 3.2 50 600 550 480 0 to 90 25 29 26 24 4.5 5.0 92 800 710 610 0 to 90 25 34 32 28 5.6 6.3 83 940 840 750 0 to 90 25 34 32 28 198 x 900 x 620 22 ARXD24GALH 7.1 8.0 122 1,330 1,240 1,100 0 to 50 25 35 32 29 198 x 1,100 x 620 26 3.6 4.0 54 600 510 450 0 to 90 25 30 27 24 kW W m3/ h Pa dB(A) mm kg mm Model name Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.

Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. 17 18 198 x 700 x 620 ø6.35 ø12.70 ø9.52 ø15.88 230V ~, 50Hz ø25 (I.D.) ; ø32 (O.D.) Slim Duct / Slim Concealed Floor 22 23 INDOOR UNITS

Optional parts Remote Sensor Unit : Long Life Filter : Flange (Square) : UTY-XSZX UTD-LF25NA UTD-SF045T Flange (Round) : IR Receiver Unit : Drain Pump Unit : UTD-RF204 UTB-YWC UTZ-PX1NBA Low energy consumption by DC fan motor. Selectable with a wide range of static pressure. Models ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH Two-direction drain piping 1.Control box 2.Fan casing 3.Fan 4.Motor New model 1 4 3 2 Bottom panel: 2 pieces The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.

Selectable with a wide range of static pressure It is possible to change of static pressure range 0 to 150Pa. Two-direction drain piping Duct indoor unit Installation styles Embedded in Ceiling Hanging from Ceiling Easy maintenance See below for the case of rear suction type Can be installed for various location It can be installed in such locations as high-rise condominiums by low static pressure design. It can also be installed in wide spade when high static pressure is required, such as for offices. Easy setting by using remote controller The change of static pressure range is possible by remote controller Static pressure range 0 to 150 Pa Slim & Compact design In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270mm, Further space savings have been achieved by mounting the electrical control box internally inside the chassis.

Low energy consumption by high efficiency DC fan motor Improved motor efficiency from previous model. 270mm 1,200 1,135mm Control box is now included as part of the main chassis One touch operating and easy to install long life filter (Optional Parts) 24 model NEW 30 / 36 / 45 model NEW Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.

Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Specifications *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size. Refrigerant piping flare connection (Liquid) : Refrigerant piping flare connection (Gas) : Drain piping connection (Drain pipe) 2 1 3 Rear view Top view Side view (R) Side view (L) Front view 240 270 107 1015 1135 173 161 447(Bolt pitch) 1177(Bolt pitch) Outlet 270 32 ø200 (knock out hole) 240 121 P.C.D. ø225 114 66 32 1 3 3 2 168 281 240 700 138 138 264 264 264 ø205 hole 82 75 Models: ARXA24 / ARXA30 / ARXA36 / ARXA45 Dimensions (Unit : mm) 7.1 8.0 94 1,280 990 840 0 to 150 40 31 27 23 36 ARXA24GBLH Cooling Heating High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain ARXA30GBLH 9.0 10.0 108 1,410 1,280 1,150 0 to 150 50 34 32 29 ARXA36GBLH 11.2 12.5 194 1,840 1,600 1,470 0 to 150 50 37 35 33 40 ARXA45GBLH 12.5 14.0 240 1,970 1,860 1,640 0 to 150 60 41 38 36 kW W m3/h Pa dB(A) mm kg mm Model name Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter ø9.52 ø25 (I.D.) ; ø32 (O.D.) 230V ~, 50Hz 270 x 1,135 x 700 ø15.88 ø19.05 Medium Static Pressure Duct 24 25 INDOOR UNITS

(unit: mm) 400 500 1,050 ARXC36GATH : 43kg Optional parts Long-Life Filter : IR Receiver Unit : Remote Sensor Unit : UTD-LF60KA UTB-YWC UTY-XSZX Volume 47.5% down Weight 42% down Front view Top view Side view (L) Side view (R) Rear view 88 400 1,080(Bolt pitch) 1,000 862 851 1,050 85 371 356 208 41 123 139 108 1 2 3 4 324 14 295 585 500(Bolt pitch) 71 Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection 2 1 3 These indoor units allow for high airflow quantities Models ARXC36GATH ARXC45GATH Models : ARXC36 / ARXC45 Low noise Heat exchanger Plastic fan Casing (Plastic) 500mm 400mm ø225mm Previous model New model (ARXC36GATH) * Model : Material (At 100Pa : Actual noise measurement value) ARXC36GATH : Plastic fan [45dB(A)] Cutting off the corners of the conventional indoor unit front panel and fan casing, has enabled less turbulent air flow.

Low noise is realized by adopting a plastic case and a plastic fan. ARXC36GATH ARXC45GATH Dimensions (Unit : mm) Models: ARXC36 / ARXC45 Models : ARXC36 Easy installation (Compact size & Lightweight) A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight.

Max. 250Pa 11.2 12.5 405 2,600 1,950 1,450 100 to 200 100 45 38 32 43 ARXC36GATH Cooling Heating High Med Low High Med Low Liquid Gas Drain ARXC45GATH 12.5 14.0 715 3,500 3,000 2,460 100 to 250 100 49 45 42 46 230V ~, 50Hz 400 x 1,050 x 500 ø9.52 (Flare) ø19.05 (Flare) ø25 (I.D.) ; ø32 (O.D.) kW W m3/ h Pa dB(A) mm kg mm Model name Power source Capacity Input power Airflow rate Static pressure range Standard static pressure Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Specifications Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.

Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.

Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. High Static Pressure Duct 26 27 INDOOR UNITS Design also corresponding to high static pressure

Super vane (Unit : mm) 990 199 655 Symmetrical, slim and compact design. Compact design A combination of up/down and right/left directional swing allows three-dimensional air direction control. Double auto swing 4 4 5 3 3 2 2 1 1 UP and DOWN SWING RIGHT and LEFT SWING 5 steps selectable 4 steps selectable 5 steps selectable Flexible installation Auto-closing louvre • High power • Wide rotation range • High efficiency High power DC fan motor Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection 2 1 3 1 2 1 2 3 3 Example for ceiling installation Floor console Under ceiling Example for floor installation Double Louvre Super vane with newly developed special configuration boosts airflow sending cool air quickly to every corner of the room.

When operation is stopped, the louvres will automatically close. (This function is available on all non-ducted models.) The slim and lightweight design allow the unit to be suspended from the ceiling or installed on the floor. This type suits many room designs Models AB*A12GATH AB*A14GATH AB*A18GATH AB*A24GATH Floor standing 230V ~, 50Hz 3.6 4.0 30 660 570 490 36 32 28 25 AB*A12GATH AB*A14GATH AB*A18GATH AB*A24GATH 7.1 8.0 99 1,000 820 680 47 42 37 27 5.6 6.3 74 1,000 720 580 46 39 35 26 Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter Cooling Heating High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain kW W m3/ h dB(A) mm kg mm AB*: ABY(FUJITSU), ABH(GENERAL) Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

ø9.52 ø15.88 199 x 990 x 655 ø25 (I.D.) ; ø32 (O.D.) ø6.35 ø12.70 Dimensions (Unit : mm) Models: AB*A12 / AB*A14 / AB*A18 / AB*A24 Specifications 4.5 5.0 42 780 640 550 40 36 34 26 Floor / Ceiling 28 29 INDOOR UNITS

Auto airflow direction and auto swing Double auto swing and wide airflow Dimensions (Unit : mm) Models: AB*A30 / AB*A36 / AB*A45 / AB*A54 Optional drain pump unit allows flexible installation design. High Efficiency long-life filter doubles the life of the filter compared to standard filters. Fresh air intake Long airflow Long distance air-flow Long-life filter 4 3 2 1 4 steps selectable 5 steps selectable Up and down Right and left High lift drain pump • High power • Wide rotation range • High efficiency High power DC fan motor Slim & Compact design Outdoor Indoor Fresh air Optional parts Drain Pump Unit : UTR-DPB24T Flange : UTD-RF204 General installation pattern which suspends the indoor unit from the ceiling.

Installation Open Installation pattern where part of the indoor unit is embedded into the ceiling.

Concealed Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient. (Field Supplied) Wall mounted Long Airflow ensures comfort to every corner of a large room. Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain piping connection 2 1 3 1 3 2 3 Easily concealed in any installation Models AB*A30GATH AB*A36GATH AB*A45GATH AB*A54GATH Hight 240mm Max. 500mm 230V ~, 50Hz 9.0 10.0 66 1,630 1,370 1,140 42 38 33 46 ø9.52 ø15.88 Cooling Heating High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain Specifications 11.2 12.5 85 1,690 1,400 1,170 45 38 34 14.0 16.0 180 2,270 1,780 1,280 51 45 36 12.5 14.0 131 2,010 1,600 1,230 48 42 35 48 ø9.52 ø19.05 kW W m3/ h dB(A) mm kg mm Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter AB*: ABY(FUJITSU), ABH(GENERAL) Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

240 x 1,660 x 700 ø25 (I.D.) ; ø32 (O.D.) AB*A30GATH AB*A36GATH AB*A45GATH AB*A54GATH Ceiling 30 31 INDOOR UNITS

Filter features Open panel Width 790mm Compact size Powerful output even compact design Though the indoor unit is compact, it features a large, high pressure cross fan (90mm diameter) in a centre mounted configuration and a Lambda type heat exchanger to provide plenty of power. Symmetrical design Symmetrical, clean design that suits all interiors. 1 2 3 4 Step Swing S w i n g 40 80 120 160 30 60 120 (ppm) (min) With no filter New filter 40 80 120 160 30 60 120 (ppm) (min) With no filter New filter 40 80 120 160 30 60 120 (ppm) (min) With no filter New filter Testing organization : Environmental Sanitary Inspection Center Test method : Deodorization Test Ammonia Trimethylamine Hydrogen sulfate Auto swing louvre 660 790 275 530 470 215 Refrigerant pipe flare connection (Liquid) Refrigerant pipe flare connection (Gas) Drain piping connection 2 2 1 1 3 3 wire wire UPWARD UPWARD 416 222 Vertical installation Install the unit as confirmed direction.

Install the unit where it will not be tilted by more than 5° Install the unit as confiremed direction . Install the unit where it will not be tilted by more than 5° Horizontal installation OUTDOOR UNIT SIDE INDOOR UNIT SIDE 65 EV kit (UTR-EV09XB/ UTR-EV14XB ) Optional parts: 121 97 65 19 32 The Auto Swing Louvre function ensures that the air direction corresponds to the mode selected. Easy maintenance Easy maintenance has been realized as the front panel can removed for easy access. Models: AS*A07 / AS*A09 / AS*A12 / AS*A14 AS*E07 / AS*E09 / AS*E12 / AS*E14 Dimensions (Unit : mm) Wall Mounted Compact and Stylish design indoor Long-life* Ion Deodorization Filter Apple-catechin Filter (*The filter can be used for approx.

3 years if it is washed under water to restore its surface action when it is dirty.) The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. High quality air conditioning by incorporation of high performance filter. Deodorizing effect (Odor reduction rate) Models (EEV internal model) AS*A07GACH AS*A09GACH AS*A12GACH AS*A14GACH Models (EEV external model) AS*E07GACH AS*E09GACH AS*E12GACH AS*E14GACH New style high power DC fan motor • High power • Wide rotation range • High efficiency • Compact size 790mm Specifications 2.2 2.8 17 490 450 370/420*1 35 33 27/31*1 AS*A07GACH Cooling Heating High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain 2.8 3.2 18 500 450 370/420*1 36 33 27/31*1 4.5 5.0 34 670 490 420 44 37 32 2.2 2.8 15 490 450 370/420*1 34 32 26/30*1 2.8 3.2 16 500 450 370/420*1 35 32 26/30*1 3.6 4.1 21 560 480 420 38 34 30 4.5 5.0 34 680 490 420 43 35 30 3.6 4.1 22 560 480 420 39 35 31 kW W m3/h dB(A) mm kg mm Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter EV Kit (option) AS*: ASY(FUJITSU), ASH(GENERAL) Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

*1 : This value is under cooling operation. AS*A09GACH AS*A12GACH AS*A14GACH AS*E07GACH AS*E09GACH AS*E12GACH AS*E14GACH 230V ~, 50Hz 230V ~, 50Hz 275 x 790 x 215 9 ø6.35 ø12.70 275 x 790 x 215 9 ø6.35 ø12.70 - ø13.8(I.D.) ; ø15.8-ø16.7(O.D.) ø13.8(I.D.) ; ø15.8-ø16.7(O.D.) UTR-EV09XB UTR-EV14XB Specifications 32 33 INDOOR UNITS

Wall Mounted Refrigerant piping flare connection (Liquid) Refrigerant piping flare connection (Gas) Drain hose connection 2 1 3 “Vertical airflow” provides powerful floor level heating Compact & Slim design Easy maintenance “Horizontal airflow” does not blow cool air directly at the occupants in the room Power diffuser Power diffuser (full open) 46 o 5 2.5 0 3 6 9 12(m) (˚C) 15 16 17 18 Outside air conditions: 35 ˚C 40% Operation contents: Cooling, Set temperature (Min set temp) 18 ˚C, airflow Hi, Air direction downward and front (24/30) 5 2.5 0 3 6 9 12(m) Outside air conditions: 2 ˚C 60% Operation contents: Heating, Set temperature (Max set temp) 30 ˚C, airflow Hi, Air direction downward and front 33 32 31 30 29 (˚C) (24/30) Ion Deodorization Filter Apple-catechin Filter Pre Filter Organic coating fin used heat exchanger Antibacterial deodorizing pre-filter with special ceramic powder Long-life* Ion Deodorization Filter Apple-catechin Filter Using different filters at both sides The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

Simplification of drain pan cleaning improves maintenance-ability. Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. (*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.) Air conditioner filter features 998mm 1120mm New model Previous model Models: AS*A18 / AS*A24 / AS*A30 Dimensions (Unit : mm) Simple & Elegant Appearance Design Models AS*A18GACH AS*A24GACH AS*A30GACH By using DC fan motor, compact design is realized.

DC fan motor 998 228 320 520 520 590 721 230V ~, 50Hz 5.6 6.3 32 840 770 690 41 39 35 AS*A18GACH AS*A24GACH AS*A30GACH Cooling Heating High Med Low High Med Low Liquid (Flare) Gas (Flare) Drain 7.1 8.0 60 1,100 910 730 48 43 35 320 x 998 x 228 15 ø9.52 ø15.88 ø12 (I.D.) ; ø16 (O.D.) 8.0 9.0 91 1,240 980 770 52 45 35 kW W m3/h dB(A) mm kg mm Model name Power source Capacity Input power Airflow rate Sound pressure level Dimensions (H x W x D) Weight Connection pipe diameter AS*: ASY(FUJITSU), ASH(GENERAL) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.

Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Specifications 34 35 INDOOR UNITS

External Switch Controller UTY-TEKX Card-key (Field supplied) Web Monitoring Tool (VRF system side) Internet or Public Telephone Line (Monitoring side) USB Adaptor*2 (Field supplied) USB Adaptor*2 (Field supplied) UTY-AMGX Air Conditioning Individual Control K* KY(FUJITSU), KG(GENERAL) Simple Remote Controller UTY-RHK* Without operation mode H*: HY(FUJITSU), HG(GENERAL) Wireless Remote Controller UTY-LNH* System For single split SU MOTU WE TH FR SA 7 3 12 6 9 15 18 21 SU MOTU WE TH FR SA 7 3 12 6 9 15 18 21 Network Convertor UTY-VGGXZ1 Service Tool UTY-ASGX Software Software R* RY(FUJITSU), RG(GENERAL) Wired Remote Controller (Touch panel) UTY-RNR* K* KY(FUJITSU), KG(GENERAL) Wired Remote Controller UTY-RNK* Outdoor unit Indoor unit Outdoor unit Indoor unit CONTROLLER Every user's needs are supported by offering a variety of controls, such as individual control, central control and building management control options.

Control System Building Management Air Conditioning Central Control USB Adaptor*2 Network Convertor UTY-VGGXZ1 Remote / Monitoring side Internet or Public Telephone Line System Controller UTY-APGX UTY-PEGX(Option) Touch Panel Controller Group Remote Controller UTY-DTG* UTY-CGG* BACnet® Gateway UTY-ABGX Network Convertor (BMS / LONWORKS® ) UTY-VLGX G* GY(FUJITSU), GG(GENERAL) G* GY(FUJITSU), GG(GENERAL) Central Remote Controller UTY-DCG* G* GY(FUJITSU), GG(GENERAL) (Field supplied) USB Adaptor*2 (Field supplied) Software Software General-purpose Building Control Computer Connectable to various sized BMS/BAS*1 or Transmission line (VRF Network) Remote controller line (2 wires) Remote controller line (3 wires) USB cable LONWORKS® Network Ethernet Signal line(Single split system) Group Remote Controller line *1.

BMS/BAS: Building Management System / Building Automation System *2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation. The devices above cannot be connected to the S series. (Except System Controller & BACnet® Gateway) 36 37 Signal Amplifier UTY-VSGXZ1 IR Receiver Unit UTB-YWC IR Receiver Unit UTY-LRH*B1 *B YB(FUJITSU), GB(GENERAL) K* KY(FUJITSU), KG(GENERAL) Simple Remote Controller UTY-RSK*

Outdoor unit Touch Panel Controller Transmission line Module link Remote Controller line (2 wires) Remote Controller line (3 wires) Group Remote Controller line Signal line (single system) USB cable Ethernet LONWORKS® Network Wired Remote Controller (Touch panel) Wired Remote Controller Indoor unit (Cassette) Group Remote Controller Indoor unit (Duct) External Switch Controller Simple Remote Controller Wireless Remote Controller Simple Remote Controller IR Receiver unit • Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring.

• Total wiring length (total length of transmission line) can be extended up to 3,600m (by using signal amplifiers). 3,600m Max. transmission line length Wiring system USB Adaptor USB Adaptor USB Adaptor USB Adaptor Network Convertor UTY-VGGXZ1 UTY-ABGX Network Convertor for LONWORKS ® UTY-VLGX Network Convertor UTY-VGGXZ1 Network Convertor UTY-VGGXZ1 Signal Amplifier UTY-VSGX Web Monitoring Tool UTY-AMGX Web Monitoring Tool Trouble free operation at all times by remote monitoring system. Transmission line line is non-polar 2-conductor. Service Tool Extensive monitoring and analysis functions for installation and maintenance.

2 Remote Controllers Indoor unit can be controlled from both remote controllers. External Switch Controller Indoor units can be controlled by combining with Card-key switch such as hotel room. System without Remote Controller Together with Touch Panel Controller, it is possible to build non remote controller system. Remote Controller line Maximum 16 units can be controlled Group Remote Controller Maximum 8 remote controller groups can be controlled Central Remote Controller Maximum 100 indoor units can be controlled. Touch Panel Controller One Touch Panel Controller can control up to 400 groups / 400 indoor units.

System Controller UTY-APGX Maximum 1,600 indoor units can be controlled. Air conditioning control Operation monitoring Status monitoring system Electricity charge calculation IR Receiver Kit Cassette type indoor unit can be controlled with Wireless Remote Controller IR Receiver Unit Duct type indoor unit can be controlled with Wireless Remote Controller.

Service Tool UTY-ASGX Big Multi system Card key Single system (VRF network system side) (Monitoring side) (Monitoring side) (Monitoring side) (Remote / Monitoring side) BACnet® Gateway BACnet® LONWORKS® BACnet® BACnet® Operator Workstation (B-OWS) NW 1 NW 2 NW 3 NW 4 Internet or Public Telephone Line Internet or Public Telephone Line LONWORKS® Network Building Management System Central Remote Controller System Controller Comparison table of Controllers Max. controllable remote controller groups Max. controllable indoor units Max. controllable groups On / Off Operation mode setting Fan speed setting Room temp.

setting Room temp. set point limitation Test operation Up/down air direction flap setting Right/left air direction flap setting Group setting RC prohibition Anti freeze setting Setback cool/heat Economy mode setting Failure Defrosting Current time Day of week R.C. prohibition Cooling/heating priority Address display Room temp Multi language Summer time Name registration Backlight Schedule timer On/off timer Sleep timer Program timer Auto off timer Day off Min. unit of timer setting (Minutes) Status monitoring system Electricity charge calculation Error history Emergency stop Control via internet E-mail notification for malfunction Key lock Item Model name Air conditioning control function Display Timer Control Period On/Off, Temp, mode, times per day Simple Remote Controller Wireless Remote Controller Group Remote Controller 8 18 - - - - - - - - - - - - - - - - - Week 4 - - - - - 10 - - - - - 1 16 - - - - - - - - - - - - - - Week 8 - - 10 ● 30 - - - - - 1 16 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 16 - - - - - - - - - - - - - - - - - - - - - Week 4 - - - - - 30 - - - - - - 1 16 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 16 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 - - - - - - - Central Remote Controller Touch Panel Controller 400 400 400 - - Year 20 - - - - 10 - - - Simple Remote*1 Controller Wired Remote Controller Wired Remote Controller (Touch panel) *1 "Operation mode" setting is not available for this model.

*2 This function is available only through external input. control. ●: Supported — : Not supported yet ○: Supported soon 1600 1600 1600 - - - - Year 144 - - - - 10 - System Controller Software 100 100 16 - - - - - - - - - - Week 20 - - - - 10 - - - UTY-RSKY UTY-RSKG UTY-LNHY UTY-LNHG UTY-CGGY UTY-CGGG UTY-DCGY UTY-DCGG UTY-DTGY UTY-DTGG UTY-RHKY UTY-RHKG UTY-RNKY UTY-RNKG UTY-RNRY UTY-RNRG UTY-APGX CONTROLLER 38 39 *2 *2 Password setting Child lock Child lock Password setting Password setting