UPS catalogue 2015

UPS catalogue 2015

UPS catalogue 2015

UPS catalogue 2015 YOUR POWER IN SAFE HANDS

UPS catalogue 2015

E Series UPS Secure Power The E Series UPS range from Dale Power Solutions Keeping the power secure Contents 1 Introduction 2 E-Series UPS Power Matrix 4 E200R Series 1–3kVA 6 E200R+ Series 1–3kVA 8 E200+ Series 1–3kVA 10 E200 Series 1–3kVA 12 E200R Series 6–10kVA 14 E200 Series 10–20kVA 16 E300 Series 10–250kVA 20 E600 Series 10–200kVA 24 E700 Series 10–40kVA 28 E800 Series 10–600kVA 32 E900 Series 10–200kVA 36 Could your business cope without power?

37 Remote Monitoring 38 Total Secure Power Solution 39 UPS Service & Support 40 Corporate & Social Responsibility 41 E Series UPS Secure Power 42 Secure power when you need it 43 Summary of UPS AC & DC Systems 44 Delivering secure power E Series UPS Secure Power

UPS catalogue 2015

www.dalepowersolutions.com 01 Your total power solutions partner In an uncertain world, where rocketing demand is putting a strain on power supplies, you need the total confidence in your back-up power that Dale provides. Select from our standard range of UPS and generators, or our secure power projects providing your ideal standby power solution. Our integrated UPS and generator solutions provide‘no-break’ power, saving you from costly outages and downtime. We deliver flexible, innovative and cost effective secure power solutions, service and maintenance and manage the complete lifecycle of your equipment.

Manufacturing excellence Operating lean and efficient 6 Sigma designed working practices, we ensure that your exact requirements are met - from design to a finished product of the highest quality and reliability. All systems are built and tested, including customer witness testing, under the highest levels of quality control. Outstanding features Features include internal failsafe bypass, extended run times, and high input power factor. With maximum reliability and power availability you can connect several units in parallel. The E Series has multi-language touch screen displays, remote monitoring, an advanced IGBT rectifier, back-feed protection and is configurable for redundancy.

Leading edge technology The outstanding E series uses double conversion technology (VFI) with the UPS load powered continuously by the inverter. This guarantees that the critical UPS load receives a stable, clean, regulated sinusoidal power supply. Expert project management, installation and commissioning Your system is in expert hands. Project managers work with you to plan, control and co-ordinate everything from order placement, design and manufacture to installation. Our engineers join you on site to install and commission your equipment.

Future proof modular flexibility A modular approach to system design includes hot-swappable modules ensuring maximum up time.

Your power solution lifecycle is totally flexible with ease of maintenance and expandability. As your power requirement grows so can your power solution, guaranteeing continued reliability. Safe removal and insertion of the UPS modules ensure no risk to the critical load. Protecting the environment Our systems are designed and manufactured using the minimum amount of resources, can be upgraded or refurbished to reduce material consumption and extend product life, and can be safely recycled, avoiding the need for system disposal. The E Series is designed with selectable ECO-mode, guaranteeing high operation efficiency.

Unrivalled service and support Outstanding service and maintenance support is backed by more than 77 years’experience, a worldwide team of service personnel, access to a comprehensive parts and spares archive and 24/7 expert help available. Setting the benchmark in UPS solutions

UPS catalogue 2015

E Series UPS Secure Power E-Series UPS Power Matrix At a glance 02 E200 E200R Power (kVA) 1:1 3:1 3:1 1:1 E200R+ 1:1 E300 3:3 E200+ 1:1 1 kVA 2 kVA 3 kVA 6 kVA 10 kVA 15 kVA 20 kVA 30 kVA 40 kVA 50kVA 60 kVA 80 kVA 100 kVA 120 kVA 160 kVA 200 kVA 250 kVA 300 kVA 400 kVA 500 kVA 600 kVA

UPS catalogue 2015

www.dalepowersolutions.com 03 E600 E600 Module 1:1 3:1 3:3 3:1 3:3 1:1 3:3 E700 3:3 E800 3:3 E900

UPS catalogue 2015

E Series UPS Secure Power E200R Series An Advanced UPS Technology 1:1 Phase | 1–3 kVA | 0.8PF 4 Features 3 High frequency, double conversion on-line technology 3 Rotatable LCD – suitable for 19" rack or slim tower 3 Fully digital DSP control 3 Wide input voltage range 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Smart RS232 communications with monitoring software 3 USB communications port included 3 Optional relay or SNMP communications card 3 Matching EER battery packs available 3 E suffix models have no internal battery and increased charging capacity RELAY CARD BATTERY Pack SNMP card Intelligent Slot options: OR

UPS catalogue 2015

www.dalepowersolutions.com 5 Application Server, Telecommunications, Networking, Desktop, CCTV Specifications UPS Model E201R E202R E203R Capacity 1000VA / 800W 2000VA / 1600W 3000VA / 2400W Input Voltage Range 115V AC – 295V AC, load < 70% 160V AC – 295V AC, load > 70% Phase Single phase Frequency 46 – 54 ±0.5Hz or 56 – 64Hz ±0.5Hz (auto sensing) Power Factor >0.98 Output Voltage 220 / 230 /240V AC ±2% (factory set) Phase Single phase Frequency range 50 / 60Hz ±0.2% THD (Linear Load) < 3% THD (Non-Linear Load) < 6% Overload Capability >110% for 30 sec then transfer to bypass >150% for 0.3 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.8 Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm Battery mode: Inverter turns off after 5 cycles & provides an alarm Bypass mode: AC input fuse blows or circuit breaker operates Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency On-line mode: ≥ 87% On-line mode: ≥ 88% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 24V DC 48V DC 72V DC Battery 2× 12V / 9Ah 4× 12V / 9Ah 6× 12V / 9Ah Backup Time At Half Load 10 mins 10 mins 10 mins Backup Time At Full Load 4 mins 4 mins 4 mins Charge Current Internal battery: 1A Recharge Time 90% capacity after 8 hours charging Environment Temperature 0°C to +40°C Relative Humidity 0 – 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25°C to +55°C Communication Standard: RS232, USB Optional: SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 45dBA Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 12.0kg 21.1kg 26kg Dimensions (H × W × D) 400 × 380 × 86.5 mm 440 × 520 × 131 mm Standard Accessories Control Software Yes Yes Yes Input & Output Leads Yes Yes Yes Data Lead Yes Yes Yes User Manuals Yes Yes Yes Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.

All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

UPS catalogue 2015

E Series UPS Secure Power E200R+ Series An Advanced UPS Technology 1:1 Phase | 1–3 kVA | 0.9PF 6 Features 3 High frequency, double conversion on-line technology 3 Fully digital DSP control 3 User friendly LCD interface 3 Wide input voltage range 3 Cold start function 3 Advanced battery management 3 Selectable Eco mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Smart RS232 communications with monitoring software 3 USB communications port included 3 Optional relay or SNMP communications card 3 Matching EER+ battery packs available 3 Programmable load shedding in battery mode UPDATED RELAY CARD BATTERY Pack SNMP card Intelligent Slot options: OR

UPS catalogue 2015

www.dalepowersolutions.com 7 Application Server, Telecommunications, Networking, Desktop, CCTV Specifications UPS Model E201R+ E202R+ E203R+ Capacity 1000VA / 900W 2000VA / 1800W 3000VA / 2700W Input Voltage Range 160V AC – 295V AC Phase Single phase Frequency 46 – 54Hz ±0.5Hz or 56 – 64Hz ±0.5Hz (auto sensing) Power Factor >0.98 Output Voltage 200 / 208 / 220 / 230 / 240V AC ±2% (factory set) Phase Single phase Frequency Range 50 / 60Hz ±0.02Hz THD (Linear Load) < 3% THD (Non-Linear Load) < 5% Overload Capability Up to 130% for 30 sec then transfer to bypass 130% – 200% for 0.3 sec then transfer to bypass >200% for 0.2 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.9 Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm Battery mode: Inverter turns off after 5 cycles & provides an alarm Bypass mode: AC input fuse blows or circuit breaker operates Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency ≥ 89% AC mode ≥ 84% battery mode Battery Model 12V valve regulated lead acid maintenance free DC Voltage 36V DC 72V DC 72V DC Battery 3× 12V / 9Ah 6× 12V / 9Ah 6× 12V / 9Ah Backup Time At Half Load 14 mins 14 mins 8 mins Backup Time At Full Load 5 mins 5 mins 3 mins Charge Current 1A Recharge Time 90% capacity after 5 hours charging Environment Temperature 0°C to +40°C Relative Humidity 0 – 90% (non-condensing) Altitude 1500m maximum Storage Temperature -25°C to +55°C Communication Standard: RS232, USB Optional: SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 55dBA Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 18.7kg 31.3kg 33.0kg Dimensions (H × W × D) 86.5 × 440 × 430 mm 86.5 × 440 × 690 mm Standard Accessories Control Software Yes Yes Yes Input & Output Leads Yes Yes Yes Data Lead Yes Yes Yes User Manuals Yes Yes Yes Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.

All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

UPS catalogue 2015

E Series UPS Secure Power E200+ Series An Advanced UPS Technology 1:1 Phase | 1–3 kVA | 0.9 PF 8 Features 3 High frequency, double conversion on-line technology 3 Fully digital DSP control 3 User friendly LCD interface 3 Wide input voltage range 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Smart RS232 communications with monitoring software 3 USB communications port included 3 Optional relay or SNMP communications card 3 Matching EE+ battery packs available 3 Programmable load shedding in battery mode 3 Emergency Power Off function RELAY CARD BATTERY PACK SNMP CARD Intelligent Slot options: OR

www.dalepowersolutions.com Application Server, Telecommunications, Networking, Desktop, CCTV Specifications UPS Model E201+ E202+ E203+ Capacity 1000VA / 900W 2000VA / 1800W 3000VA / 2700W Input Voltage Range 160V AC - 295V AC Phase Single phase Frequency 46 – 54Hz ±0.5Hz or 56 – 64Hz ±0.5Hz (auto sensing) Power Factor 0.98 Output Voltage 200/208/220/230/240V AC ±2% (factory Set) Phase Single phase Frequency Range 50 / 60Hz ±0.2% (auto selected at start up) THD (Linear Load) < 3% THD (Non-Linear Load) < 5% Overload Capability Up to 130% for 30 sec then transfer to bypass 130% - 200% for 0.3 sec then transfer to bypass >200% for 0.2 sec then transfere to bypass Crest Factor 3:1 (max) Power Factor 0.9 Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm Battery Mode: Inverter turns off after 5 cycles & provides an alarm Bypass mode: AC input fuse blows or circuit breaker operates Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency ECO mode: ≥94% AC mode: ≥89% Battery mode: ≥84% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 36V DC 72V DC 72V DC Battery 3x 12V / 9Ah 6x 12V / 9Ah 6x 12V / 9Ah Backup Time At Half Load 14 mins 14 mins 8 mins Backup Time At Full Load 5 mins 5 mins 3 mins Charge Current 1A Recharge Time 90% capacity after 5 hours charging Environment Temperature 0°C to +40°C Relative Humidity 0 – 95% (non-condensing) Altitude 1500m maximum without derate Storage Temperature -25°C to +55°C Communication Standard: RS232, USB Optional: SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 55dBA Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 13.0kg 24.6kg 25.5.0kg Dimensions (H × W × D) 215 x 144 x 409 mm 337 x 199 x 466 mm Standard Accessories Control Software Yes Yes Yes Input & Output Leads Yes Yes Yes Data Lead Yes Yes Yes User Manuals Yes Yes Yes 9 Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.

All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

E Series UPS Secure Power E200 Series An Advanced UPS Technology 1:1 Phase | 6–10 kVA | 0.8PF 10 RELAY CARD SNMP card Parallel card Intelligent Slot options: BATTERY pack Features 3 High frequency, double conversion on-line technology 3 Fully digital DSP control 3 Wide input voltage range 3 Integral‘hot-swap’maintenance bypass module 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Parallel capacity or redundancy (maximum 4 units) requires a parallel card as factory fitted option 3 Smart RS232 communications with monitoring software 3 Optional relay or SNMP communications card 3 Matching EE2000 battery packs available 3 E suffix models have no internal battery and increased charging capacity 3 Internal removable bypass switch

www.dalepowersolutions.com 11 Application Server, Telecommunications, Networking, Desktop, CCTV Specifications UPS Model E206 E206E E2010 E2010E Capacity 6000VA / 4800W 10000VA / 8000W Input Voltage Range 120V AC – 276V AC Phase Single phase Frequency 40 – 70Hz Power Factor ≥ 0.99 Output Voltage 220 / 230V AC ±2% Phase Single phase Frequency Range 50 / 60Hz (user adjustable) THD (Linear Load) ≤ 2% THD (Non-Linear Load) ≤ 6% Overload Capability ≤ 130% load for 10 min then transfer to bypass > 130% load for 1 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.7 (16 or 18× 12V batteries) or 0.8 (20× 12V batteries) Short Circuit Protection On-line mode: ≥ 5 cycle duration, inverter turns off, no transfer to bypass, unit alarms Battery mode: ≥ 5 cycle duration, inverter turns off, bypass unavailable, unit alarms Bypass mode: Input fuse blows or breaker operates, no alarm Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency On-line mode: ≥ 90% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 192V DC 192 / 216 / 240V DC 192V DC 192 / 216 / 240V DC Battery 16× 12V / 9Ah 16 / 18 / 20× 12V 16× 12V / 9Ah 16 / 18 / 20× 12V Backup Time At Half Load 14.3 min Depends on ext.

battery 6.5 min Depends on ext. battery Backup Time At Full Load 5.5 min Depends on ext. battery 2.5 min Depends on ext. battery Charge Current 1.0A 1.0 – 6.0A (selectable) 1.0A 1.0 – 6.0A (selectable) Recharge Time 90% capacity after 8 hrs Depends on ext. battery 90% capacity after 8 hrs Depends on ext. battery Environment Temperature 0°C to +40°C Relative Humidity 0 – 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25°C to +55°C Communication Standard: RS232 Optional: USB, SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 55dBA Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 77kg (nett) / 84 kg (gross) 35kg (nett) / 42kg (gross) 80kg (nett) / 87kg (gross) 38kg (nett) / 45kg (gross) Dimensions (H ×W × D) mm 655 × 250 × 590 mm 655 × 250 × 590 mm Standard Accessories Control Software Yes Input & Output Leads Optional extra Battery Leads Optional extra Data Lead & User Manual Yes Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.

All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. Internal removable bypass switch

E Series UPS Secure Power E200R Series An Advanced UPS Technology 3:1 or 1:1 | 6–10 kVA | 0.9PF 12 RELAY CARD SNMP card Intelligent Slot options: OR Features 3 High frequency, double conversion on-line technology 3 Input can be configured for either 3:1 or 1:1 operation 3 Rotatable LCD – suitable for 19" rack or slim tower 3 Fully digital DSP control 3 Wide input voltage range 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Up to 4 units can be operated in parallel 3 Smart RS232 communications with monitoring software 3 USB communications port included 3 Optional relay or SNMP communications card 3 Matching EER2000 battery pack available BATTERY pack

www.dalepowersolutions.com 13 Application Server, Telecommunications, Networking, Desktop, CCTV Specifications UPS Model E21306RE E21310RE Capacity 6000VA / 5400W 10000VA / 9000W Input Rated Voltage 380 / 400 / 415V AC or 220 / 230 / 240V AC Voltage Range 120V AC – 276V AC Line – Neutral or 208V AC – 478V AC Line – Line Phase 3 Phase 4 Wire & Earth or 1 Phase 2 Wire & Earth Frequency 40 – 70Hz Power Factor ≥0.99 Output Voltage 220 / 230 / 240V AC ±2% Phase Single phase Frequency Range 50 / 60Hz ± 0.2Hz (user adjustable) THD (Linear Load) ≤ 2% THD (Non-Linear Load) ≤ 5% Overload Capability AC Mode: ≤110% for 3 min, ≤125% for 30 sec, ≤150% for 1 sec, >150% shutdown immediately, transfer to bypass Battery Mode: ≤110% for 30 sec, ≤125% for 1 sec, ≤150% for 0.2 sec, >150% shutdown immediately Crest Factor 3:1 (max) Power Factor 0.9 Short Circuit Protection Yes Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency On-line mode: ≥ 90% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 192 / 216 / 240V DC Backup Time At Half Load Backup Time At Full Load Charge Current 6A (Maximum) Recharge Time 90% capacity after 8 – 10 hours charging Environment Temperature 0°C to +40°C Relative Humidity 0 – 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25°C to +55°C Communication Standard: USB, RS485 & Parallel Port Optional: SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 55dBA Safety & EMC CE marked to EN62040-1-1:2008 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 23.0kg 25.0kg Dimensions (H × W × D) 131 × 443 × 580 mm Standard Accessories Control Software Yes Yes Input & Output Leads Yes Yes Data Lead Yes Yes User Manuals Yes Yes Battery Leads Optional extra Optional extra Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.

All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. Depends on the external battery capacity

E Series UPS Secure Power 14 E200 Series An Advanced UPS Technology 3:1 Phase | 10–20kVA | 0.8PF Features 3 High frequency, double conversion on-line technology 3 Fully digital DSP control 3 Wide input voltage range 3 Integral‘hot-swap’maintenance bypass module on E2310(E) model 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Parallel capacity or redundancy (maximum 4 units) requires a parallel card as factory fitted option 3 Smart RS232 communications with monitoring software 3 Optional relay or SNMP communications card 3 Matching EE2000 battery packs available for E2310(E) model RELAY CARD SNMP card Parallel card Intelligent Slot options:

www.dalepowersolutions.com 15 Application Server, Telecommunications, Networking, Desktop, CCTV Specifications UPS Model E2310E E2315E E2320E Capacity 10000VA / 8000W 15000VA / 12000W 20000VA / 16000W Input Voltage Range 176V AC to 275V AC Line – Neutral Phase 3 Phase 4 Wire & Earth Frequency 40 – 70Hz Power Factor ≥ 0.99 Output Voltage 220 / 230V AC ±2% Phase Single phase Frequency Range 50 / 60Hz (user adjustable) THD (Linear Load) ≤ 2% THD (Non-Linear Load) ≤ 6% Overload Capability ≤ 130% load for 10 min then transfer to bypass > 130% load for 1 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.7 (16 or 18× 12V batteries) or 0.8 (20× 12V batteries) Short Circuit Protection On-line mode: ≥ 5 cycle duration, inverter turns off, no transfer to bypass, unit alarms Battery mode: ≥ 5 cycle duration, inverter turns off, bypass unavailable, unit alarms Bypass mode: Input fuse blows or breaker operates, no alarm Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency On-line mode: ≥ 90% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 192 / 216 / 240V DC Battery 16 / 18 / 20× 12V blocks Backup Time At Half Load Depends on external battery Backup Time At Full Load Depends on external battery Charge Current 1.0 – 6.0A (selectable) Recharge Time Depends on external battery Environment Temperature 0°C to +40°C Relative Humidity 0 – 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25°C to +55°C Communication Standard: RS232 Optional: USB, SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 55dBA Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 40kg 45kg 45kg Dimensions (H ×W × D) mm 655 × 250 × 590 mm 655 × 250 × 590 mm Standard Accessories Control Software Yes Input & Output Leads Optional extra Battery Leads Optional extra Data Lead & User Manual Yes Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.

All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.

E Series UPS Secure Power E300 Series An Advanced UPS Technology 3:3 Phase | 10 – 250kVA | 0.8PF 16 Features 3 High frequency double conversion on-line UPS 3 Fully digitised microprocessor control 3 Parallel capacity or redundancy (maximum 4 units) 3 Wide input voltage range from single or dual source 3 Open architecture design provides full access for servicing 3 Intelligent battery charge management 3 RS232/RS485 communication with monitoring software 3 Short circuit and overload protection 3 Over temperature and over humidity protection 3 EMI and RFI noise filtering 3 ECO Mode 3 User friendly LCD interface 3 Cold start and programmable auto re-start functions (optional extra) 3 Fan speed auto control with load variation 3 Built-in static and maintenance bypass switches 3 Back feed protection between UPS output and mains supply 3 Emergency Power Off function 3 Low THD & high input power factor for diverse generator compatibility 3 Soft start with programmable power walk-in 3 Optional temperature compensated battery charging 3 Optional SNMP, relay card and remote monitoring panel 3 Optional galvanic isolation transformer 3 Nicad battery option available relay card SNMP card Intelligent Slot options: UPDATED

www.dalepowersolutions.com 17 Common Specifications Input Voltage Range 176V AC to 264V AC Line-Neutral Phase 3 Phase 4 Wire & Earth Frequency 50 / 60Hz ±10% (user adjustable) Power Factor > 0.99 Output Voltage 220 / 230V AC Line-Neutral (user adjustable) Phase 3 Phase 4 Wire & Earth Frequency range 50 / 60Hz (user adjustable) THD (Linear Load) < 2% THD (Non-Linear Load) < 3% Efficiency On-line mode: 93% ECO mode: 98% Overload Capacity 125% load for 10 min, 150% load for 1 min Crest Factor 3:1 Power Factor 0.8 Short Circuit Protection IGBT controlled electronic protection Waveform True sine wave Transfer Time 0ms (on-line mode) Battery External Up to 50 x 12V mono blocks (600V DC Nominal) Environment Altitude 1000m at rated power Operate Temperature 0°C to 40°C Relative Humidity 0 – 95% (non-condensing) Communication Standard: RS232 / RS485 Optional: SNMP and relay cards, remote monitoring panel LCD Screen Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Double conversion on-line or ECO line interactive (user selectable) Mimic panel overview of UPS operation and alarms Noise Level

E Series UPS Secure Power E300 Series 18 Automatic adjustment of charging parameters based on the battery configuration entered via the LCD panel. Real-timebatterymanagementinformation is displayed on the LCD, such as battery capacity(aspercentageortimeremaining). Temperaturecompensatedbatterycharging monitors are available to monitor the internal and external battery temperature with a feedback control loop to adjust the charge current rate accordingly. Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load. DSP Controlled IGBT Inverter The DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads.

The DSP circuitry is embedded within a single control board to reduce hardware and improve noise immunity. Complex control algorithms are utilised with floating point controllers to ensure uninterrupted operation and protection of the loads in abnormal conditions that may cause failure. The DSP control system achieves fast dynamic response for non-linear loads and high power factor under various load conditions. Static & Manual (Maintenance) Bypass Static and manual bypass switches are included as standard, with operational characteristics as follows: Static Bypass This feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition.

DSP Power Factor Corrected IGBT Rectifier IGBT power factor correction technology provides an input power factor close to unity (≥0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads.

The high input power factor leads to reduced electricity consumption, minimised switchgear and circuit protection, cabling and generator requirements, thus reducing investment cost. Parallel and Redundant Operation Capability to connect up to 4 units in parallel to provide increased power capacity or redundancy. All parallel units can be operated from the front panel of any UPS. Power Increase Units can be connected in parallel to increase the total capacity of the system. When an inverter goes offline, the critical loads are automatically transferred to bypass. Redundancy Units can be connected in parallel to provide redundancy for absolute reliability.

In parallel redundant mode, the number of units (N) supply the load and an extra unit is provided in case of failure (N+1). All units share the load current equally. When a unit goes offline, due to failure or maintenance, the standby unit continues to supply the critical load without any interruption.

AdvancedBatteryManagement Intelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system. The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line.

To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics. Manual Bypass This feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load. Optional Single or Dual Source Operation To increase flexibility, the UPS input can be fed by single or dual sources.

In dual configuration, the rectifier is fed from the utility (main source), and the static and maintenance bypasses are fed from a secondary source.

Open Architecture Design The UPS incorporates an open architecture design to facilitate full access to replace parts quickly and easily, resulting in low Mean Time To Repair (MTTR). Diverse Generator Compatibility Thanks to the robust IGBT rectifier, the E300 series UPS is uniquely compatible with a diverse range of sources, in particular, x4

www.dalepowersolutions.com 19 Application Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education generators.

Input current total harmonic distortion (THDi) of less than 3% is achieved without compromising efficiency. The high input power factor enables a generator to be utilised with a power rating only 20% higher than the UPS. Power walk-in can be adjusted from 5 to 15 seconds. Based on the current measured on the input, the UPS gradually increases the power supplied from the utility source to the load.The power, delivered by the utility source to the load, varies according to the input voltage, current and power factor. Back Feed Protection Back feed protection prevents current from the UPS output feeding back to the UPS input terminals, thereby protecting maintenance personnel from electric shock hazards whilst working on the incoming supply side of the system.

Reverse Energy Tolerance for Regenerative Loads The E300 series UPS is suitable for use with regenerative loads, such as synchronous motors. Regenerative loads pump energy back to the mains supply. Traditionally, UPS systems would burn this feedback energy, resulting in lower operating efficiency. The IGBT rectifier in the E300 series UPS is capable of absorbing intermittent load generated power. This reverse power tolerance facilitates the execution of important system operations, such as closed transition transfers of the UPS load directly to an engine generator source. Lower Total Cost of Ownership The high efficiency operation of the UPS means that less energy is consumed to supply power to the protected loads.

As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements. With reduced THDI and high 0.99 input powerfactor,switchgear,circuitprotection, cabling and generator requirements are minimised, thus reducing investment cost. Advanced User Interface The UPS operating information and parameter settings are displayed in 4 different languages and can be accessed using the large user friendly, data rich LCD and system LED mimic panel. The UPS is capable of recording up to 500 events. Green ECO Mode of Operation The E300 series UPS can be operated in high efficiency ECO mode (98%) providing green energy savings through reduced power consumption.

Emergency Power Off (EPO) The EPO function is designed to switch off the UPS in an emergency situation (eg. fire, flood). Operation of the EPO turns off the rectifier and inverter and cuts power to the load immediately (both the inverter and bypass lines). The EPO also prevents the battery from charging or discharging. With the utility input supply present, the UPS control circuits remain energised, even though the output is turned off. To remove all power from the UPS, the external feeder breaker must be opened. Auto Re-start Whentheutilityandbypasssourcesfail,the UPS draws power from the battery system to supply the load, until the batteries are depleted.

Once the batteries reach their End of Discharge threshold, the UPS will shut down. The UPS will automatically re-start once the utility power is restored and output power to the load will be delivered. The UPS also incorporates a programmable automatic start time delay. Advanced Communications Awiderangeofadvancedcommunication options are available: External Battery Temperature Sensor One module is fitted to each external battery cabinet to monitor the battery temperature. A feedback control loop within the UPS adjusts the charge current based on the battery temperature, optimising battery performance and longevity.

Relay Alarms Card Isolated, volt-free dry contacts indicate the UPS operating status and the presence of alarm conditions. Fully programmable to facilitate the capture of a diverse range of operating and alarm conditions. Opto-isolated inputs allow the UPS to be controlled remotely.

RS232/RS485 Serial Port The UPS operating parameters can be observed and controlled locally using an RS232/RS485 communications port. Real time notification of changes in UPS status is reported to users by SMS or e-mail. SNMP Network Card Enables monitoring and control of the UPS operation by ethernet or internet connection. Allows the remote execution of scheduled events and the shutdown / reboot of the UPS and multiple servers. Full event log and data management. Real time notification of changes in UPS status reported to users by audible alarm, SMS or e-mail. Software supports Windows, Linux, Mac, Solaris, Open VMS and IBM operating systems.

Remote LCD and LED Mimic Panel Facilitates the monitoring and control of theUPSoperations,eventsandparameters from a remote location.

E Series UPS Secure Power 20 E600 Series An Advanced UPS Technology 1:1, 3:1, 3:3 Phase | 10 – 200kVA | 0.9PF RELAY CARD SNMP Intelligent Slot options: Features 3 Hot swappable modular design 3 Flexible and expandable UPS power solution 3 19" cabinets available in full and half height format 3 Modular design capable of housing either 5× or 10× power modules 3 Power modules available in 10 and 20kVA ratings 3 Configurable N+1 modular redundancy 3 Parallel system capability (maximum 4x cabinets) 3 High frequency double conversion on-line technology 3 Wide input voltage range 3 Intelligent battery charge management 3 Programmable battery charge current 3 Short circuit and overload protection 3 EMI and RFI noise filtering 3 Smart RS232 communication with monitoring software 3 Fully digitised microprocessor control 3 Large touch screen LCD interface 3 Built-in maintenance bypass 3 Emergency Power Off function 3 Optional SNMP card or relay card 3 Optional hot plug internal batteries BATTERY Pack UPDATED 96% Efficiency at half load UP TO

www.dalepowersolutions.com 21 Specifications Cabinet Model E61150 E63150 E631100 E633100 E633200 Maximum Rating 10 – 50kVA 10 – 50kVA 10 – 100kVA 10 - 100kVA 10 - 200kVA 8 – 40kW 8 – 40kW 8 – 80kW 9 – 90kW 9 – 180kW Input Voltage range 120 to 276V AC Line - Neutral 220 / 230V AC Line - Neutral 380 / 400 / 415 AC Line - Line Phase 1 Phase 2 Wire & Earth 3 Phase 4 Wire & Earth 3 Phase 4 Wire & Earth Frequency 40 – 70Hz Power factor ≥0.99 Output Voltage 220 / 230V AC Line – Neutral 220 / 230V AC Line – Neutral 380 / 400 / 415V AC Line – Line Phase 1 Phase 2 Wire & Earth 1 Phase 2 Wire & Earth 3 Phase 4 Wire & Earth Frequency range 50-60Hz THD ≤2% with linear load ≤5% with non-linear load Efficiency Utility mode > 90% Overload capability

E Series UPS Secure Power DSP Power Factor Corrected IGBT Rectifier Latest IGBT power factor correction technology provides an input power factor close to unity (≥0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads. N+X Parallel Modular Redundancy The E600 series provides N+X parallel modular redundancy for absolute reliability. When a module goes offline, due to failure or maintenance, the remaining modules continue to supply the load without any interruption. The level of redundancy can be set to suit the criticality of the protected load.

Should the load increase above the redundancy threshold, the UPS will alarm to notify the user there is insufficient capacity available to maintain the load if a module fails. This allows preventative action to be taken (decrease load or install additional UPS modules).

High Availability & MTBF All UPS modules share the load current equally. With two modules configured for redundancy, the UPS system achieves 99.999% availability and the Mean Time Before Failure (MTBF) exceeds 15,000,000 hours, satisfying the reliability requirements of the critical load. The UPS design incorporates‘drawer style’ hot-swap UPS modules to facilitate quick and easy replacement for low Mean Time To Repair (MTTR). DSP Controlled IGBT Inverter The DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads.

Advanced Battery Management Intelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system. 3 Powerful 6A charger built into each UPS module with the ability to freely set the charge current level. 3 Automatic adjustment of charging parameters based on the battery configuration settings. 3 Real-time battery management infor- mation is displayed on the LCD, such as battery capacity (as percentage or time remaining).

3 Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load. The batteries can also be ‘hot- swapped’ without disconnection of the UPS. SingleorDualSourceOperation For increased flexibility, the E600 series UPS is available with a split bypass, enabling the UPS input to be fed by single or dual sources. In dual configuration, the rectifier is fed from the utility (main source) and the static and maintenance bypass are fed from a secondary source. Scalable Modular Solution 1.4m and 2.0m tall 19” cabinets are available, capable of holding up to 5 or 10 UPS modules respectively, providing scalability to expand as power demand increases.Upto4threephasecabinetsmay be connected in parallel configuration, providing a maximum output power capacity of 800kVA at 0.9 power factor.

Static & Manual (Maintenance) Bypass Static and manual bypass switches are included as standard, with operational characteristics as follows: Static Bypass This feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition. The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line.

To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics.

This feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load. Cold Start Operation When the utility and bypass sources are not available, the cold start feature enables the UPS to be started using the battery only. Excellent Generator Compatibility Thanks to the robust IGBT rectifier, the E600 series UPS is compatible with a diverse range of sources, including generators.

High Input power factor (0.99) and low input current total harmonic distortion (THDi)

www.dalepowersolutions.com 23 Application Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education Adjustable power walk-in allows the UPS to gradually increase the power supplied from the utility source to the load, based on the current measured on the input. Module Options available 3U high ‘drawer-style’ UPS modules with individual LCD control panel. Available in the following phase and power configurations: 3 1:1 Phase – 10kVA 3 3:1 Phase – 10kVA 3 3:3 Phase – 10 and 20kVA Common module size: H131 × W443 × D580mm Decentralised Parallel Structure Concept Each UPS module contains all the required hardware and software for autonomous operation, without reliance on the centralised monitoring module.

This increases system reliability by eliminating Single Points of Failure (SPOF). Lower Total Cost of Ownership The high efficiency operation of the UPS (≤ 98% in ECO mode and ≤96% in On-Line mode)meansthatlessenergyisconsumed to supply power to the protected loads. As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements.

With low

E Series UPS Secure Power 24 E700 Series An Advanced UPS Technology 3:3 Phase | 10– 40kVA | 0.9PF RELAY CARD SNMP Intelligent Slot options: Features 3 High frequency, double conversion on-line technology 3 Fully digital microprocessor control 3 Parallel capacity or redundancy (maximum 4 units) 3 Wide input voltage range 3 Intelligent battery charge management 3 Automatic battery charge in UPS off mode 3 RS232 communication with monitoring software 3 Short circuit and overload protection 3 Lightning and surge protection 3 EMI and RFI noise filtering 3 Line interative ECO Mode 3 User friendly LCD interface 3 Cold start function 3 Built-in maintenance bypass switch 3 Emergency Power Off function 3 Relay alarm card fitted as standard 3 Optional SNMP network card available 3 Supplied with 36x 38Ah VRLA battery as standard 3 Alternative battery capacity / autonomy available *NEWto the E Series Range

www.dalepowersolutions.com 25 Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. The Dale E700 UPS is a state-of-the-art high frequency, double conversion on-line uninterruptible power supply with internal sealed VRLA battery, providing exceptionally high performance levels. Available in output power capacities of 10kVA, 15kVA, 20kVA, 30kVA and 40kVA, all with three phase input and output. The E700 series has been engineered to protect critical loads and processes that could be disrupted by power quality power or an unexpected break in the utility supply.

Specifications UPS Model E73310B E73315B E73320B E73330B E73340B Capacity 10KVA 15KVA 20KVA 30KVA 40KVA 9KW 13.5KW 18KW 27KW 36KW Input Voltage Range 184V AC to 276V AC Line-Neutral Phase 3 Phase 4 Wire & Earth Frequency 40 – 70Hz Power Factor ≥ 0.99 Output Voltage 220/230/240V AC Line-Neutral (user adjustable) Phase 3 Phase 4 Wire & Earth Frequency Range 50 / 60Hz (user adjustable) THD (Linear Load) ≤ 2% THD (Non-Linear Load) ≤ 5% Waveform Sine wave Overload Capability ≤110%: 60 mins, ≤125%: 10 mins, ≤150%: 1 min, ≥150% automatic shutdown of UPS Crest Factor 3:1 (max) Power Factor 0.9 Short Circuit Protection Yes Transfer Time 0ms Efficiency On-line mode: ≥95% Battery mode: ≥93% Battery Type 12V valve regulated lead acid maintenance free DC Voltage 384V - 480V DC (432V DC fitted as standard) Battery 36x 12V / 38Ah Backup Time At Half Load 150 min 90 min 60 min 35 min 25min Backup Time At Full Load 60 min 35 min 25 min 12 min 8 min Charge Current 6A (max) Recharge Time Charge current can be set according to battery capacity installed Environment Temperature 0°C to 40°C Relative Humidity 0 – 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25°C to 55°C Communication Standard: RS232 Optional: SNMP LCD Display Measurements: Input/output voltage/frequency, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 55dBA Safety & EMC CE marked.

Tested to EN/IEC 62040-1-1, EN/IEC62040-2, EN/IEC60950-1, IEC6100-4 Weight & Dimensions Standard Unit Weight 600kg 602kg 604kg 606kg 608kg Dimensions (H ×W × D) mm 1200 x 600 x 780 mm Standard Accessories Relay alarm card Fitted as standard SNMP network card Optional extra

E Series UPS Secure Power DSP Power Factor Corrected IGBT Rectifier Latest IGBT power factor correction technology provides an input power factor close to unity (≥0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads. DSP control system The digital signal processor controls the power-on, star-up, input power factor control, battery charging, output stage ac voltage regulation and shutdown control for the UPS system. Parallel and Redundant Operation Capabilitytoconnectupto4unitsinparallel to provide increased power capacity or redundancy.

As each UPS contains and internal battery, an increase in autonomy time is also achieved when units are connected in parallel. Automatic master/ slave rotation is provided for additional reliability.

POWER INCREASE Unitscanbeconnectedinparalleltoincrease the total capacity of the system. When an inverter goes offline, the critical loads are automatically transferred to bypass. REDUNDANCY Units can be connected in parallel to provide redundancy for absolute reliability. In parallel redundant mode, the number of units (N) supply the load and an extra unit is provided in case of failure (N+1). All units share the load current equally. When a unit goes offline, due to failure or maintenance, the standby unit continues to supply the critical load without any interruption.

Back Feed Protection Back feed protection prevents current from the UPS output feeding back to the UPS input terminals, thereby protecting maintenance personnel from electrocution whilst working on the incoming supply side of the system.

AdvancedBatteryManagement Intelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system. Automatic adjustment of charging parameters based on the battery configuration entered via the LCD panel. Real-time battery management information is displayed on the LCD, such as battery capacity (as percentage or time remaining). Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load.

DSP Controlled IGBT Inverter The DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads. Static & Manual (Maintenance) Bypass Static and manual bypass switches are included as standard, with operational characteristics as follows: STATIC BYPASS This feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition. The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line.

During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line. To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics. MANUAL BYPASS This feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts.

Full system replacement and repair of major components does however, necessitate shutdown of the load. Discrete UPS Module Design The UPS design incorporates discrete rack mounted UPS module to facilitate quick and easy replacement for low Mean Time To Repair (MTTR). The UPS module can be exchanged with the protected load supplied by the internal maintenance bypass breaker.

Frequency Converter Mode The UPS can also be used as a frequency converter. It can accept a 40Hz to 70Hz input frequency range and provide a stable 50Hz or 60Hz output frequency. Excellent Generator Compatibility Thanks to the robust IGBT rectifier, the E700 seriesUPSiscompatiblewithadiverserange of sources, including generators. High Input power factor (0.99) and low input current total harmonic distortion (THDi)