UPS catalogue 2015

UPS catalogue 2015
YOUR POWER IN SAFE HANDS


UPS catalogue 2015
UPS catalogue 2015
E Series UPS Secure Power




     The E Series UPS range
     from Dale Power Solutions




                                  Contents
                                  1    Introduction
                                  2    E-Series UPS Power Matrix

                                   4   E200R Series 1–3kVA
                                   6   E200R+ Series 1–3kVA
                                   8   E200+ Series 1–3kVA
                                  10   E200 Series 1–3kVA
                                  12   E200R Series 6–10kVA
                                  14   E200 Series 10–20kVA
                                  16   E300 Series 10–250kVA
                                  20   E600 Series 10–200kVA
                                  24   E700 Series 10–40kVA
                                  28   E800 Series 10–600kVA
                                  32   E900 Series 10–200kVA
                                  36   Could your business cope
                                 		    without power?
                                  37   Remote Monitoring
                                  38   Total Secure Power Solution
                                  39   UPS Service & Support
                                  40   Corporate & Social Responsibility
                                  41   E Series UPS Secure Power
                                  42   Secure power when you need it
                                  43   Summary of UPS AC & DC Systems
                                  44   Delivering secure power




Keeping the power secure
UPS catalogue 2015
Setting the benchmark
in UPS solutions
Your total power solutions partner                                  Future proof modular flexibility
In an uncertain world, where rocketing demand is putting a          A modular approach to system design includes hot-swappable
strain on power supplies, you need the total confidence             modules ensuring maximum up time. Your power solution
in your back-up power that Dale provides. Select from our           lifecycle is totally flexible with ease of maintenance and
standard range of UPS and generators, or our secure power           expandability. As your power requirement grows so can
projects providing your ideal standby power solution. Our           your power solution, guaranteeing continued reliability. Safe
integrated UPS and generator solutions provide ‘no-break’           removal and insertion of the UPS modules ensure no risk to
power, saving you from costly outages and downtime. We              the critical load.
deliver flexible, innovative and cost effective secure power
solutions, service and maintenance and manage the complete          Protecting the environment
lifecycle of your equipment.
                                                                    Our systems are designed and manufactured using the
                                                                    minimum amount of resources, can be upgraded or refurbished
Manufacturing excellence                                            to reduce material consumption and extend product life,
Operating lean and efficient 6 Sigma designed working               and can be safely recycled, avoiding the need for system
practices, we ensure that your exact requirements are met -         disposal. The E Series is designed with selectable ECO-mode,
from design to a finished product of the highest quality and        guaranteeing high operation efficiency.
reliability. All systems are built and tested, including customer
witness testing, under the highest levels of quality control.       Unrivalled service and support
                                                                    Outstanding service and maintenance support is backed by
Outstanding features                                                more than 77 years’ experience, a worldwide team of service
Features include internal failsafe bypass, extended run times,      personnel, access to a comprehensive parts and spares archive
and high input power factor. With maximum reliability and           and 24/7 expert help available.
power availability you can connect several units in parallel.
The E Series has multi-language touch screen displays, remote
monitoring, an advanced IGBT rectifier, back-feed protection
and is configurable for redundancy.

Leading edge technology
The outstanding E series uses double conversion technology
(VFI) with the UPS load powered continuously by the inverter.
This guarantees that the critical UPS load receives a stable,
clean, regulated sinusoidal power supply.

Expert project management,
installation and commissioning
Your system is in expert hands. Project managers work
with you to plan, control and co-ordinate everything from
order placement, design and manufacture to installation.
Our engineers join you on site to install and commission
your equipment.




                                                                                             www.dalepowersolutions.com     01
UPS catalogue 2015
E Series UPS Secure Power




E-Series UPS Power Matrix
At a glance

                                  E200               E200R         E200+   E200R+   E300




            Power (kVA)     1:1          3:1   1:1           3:1    1:1     1:1     3:3

                 1 kVA

                 2 kVA

                 3 kVA

                 6 kVA

                10 kVA

                15 kVA

                20 kVA

                30 kVA

                40 kVA

                 50kVA

                60 kVA

                80 kVA

               100 kVA

               120 kVA

               160 kVA

               200 kVA

               250 kVA

               300 kVA

               400 kVA

               500 kVA

               600 kVA




  02
UPS catalogue 2015
E600               E600 Module         E700         E800            E900




1:1    3:1   3:3   1:1      3:1        3:3   3:3          3:3             3:3




                                             www.dalepowersolutions.com     03
UPS catalogue 2015
E Series UPS Secure Power




         E200R Series
         An Advanced UPS Technology
         1:1 Phase | 1– 3 kVA | 0.8PF



   Features
   3 High frequency, double conversion on-line
     technology
   3 Rotatable LCD – suitable for 19" rack or slim tower
   3 Fully digital DSP control
   3 Wide input voltage range
   3 Cold start function
   3 Advanced battery management
   3 Selectable ECO mode for high efficiency operation
   3 Automatic battery charge in UPS off mode
   3 Lightning and surge protection
   3 Short circuit and overload protection
   3 Automatic fan speed control with load variation
   3 Smart RS232 communications with monitoring
     software
   3 USB communications port included
   3 Optional relay or SNMP communications card
   3 Matching EER battery packs available
   3 E suffix models have no internal battery and
     increased charging capacity




                               Intelligent Slot options:
       BATTERY Pack            RELAY CARD                   SNMP card




                                                           OR




   4
UPS catalogue 2015
Specifications
  UPS Model		                                                                               E201R                                      E202R                                E203R
  Capacity		                                                                           1000VA / 800W                              2000VA / 1600W                       3000VA / 2400W
  Input                              Voltage Range		                                                                       115V AC – 295V AC, load < 70%
  			                                                                                                                      160V AC – 295V AC, load > 70%
                                     Phase 		                                                                                       Single phase
                                     Frequency		                                                                  46 – 54 ±0.5Hz or 56 – 64Hz ±0.5Hz (auto sensing)
                                     Power Factor		                                                                                     >0.98
  Output                             Voltage		                                                                          220 / 230 /240V AC ±2% (factory set)
                                     Phase		                                                                                        Single phase
                                     Frequency range		                                                                            50 / 60Hz ±0.2%
                                     THD (Linear Load)		                                                                                < 3%
                                     THD (Non-Linear Load)		                                                                            < 6%
                                     Overload Capability		                                                            >110% for 30 sec then transfer to bypass
  			                                                                                                                 >150% for 0.3 sec then transfer to bypass
                                     Crest Factor		                                                                                   3:1 (max)
                                     Power Factor		                                                                                      0.8
                                     Short Circuit Protection                   On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm
  			                                                                                                Battery mode: Inverter turns off after 5 cycles & provides an alarm
  			                                                                                                   Bypass mode: AC input fuse blows or circuit breaker operates
                                     Waveform		                                                                                      Sine wave
                                     Transfer Time 		                                                               0ms (between on-line mode & battery mode)
                                     Efficiency                                    On-line mode: ≥ 87%                                              On-line mode: ≥ 88%
  Battery                            Model		                                                                       12V valve regulated lead acid maintenance free
                                     DC Voltage                                             24V DC                                     48V DC                               72V DC
                                     Battery                                            2× 12V / 9Ah                                4× 12V / 9Ah                          6× 12V / 9Ah
                                     Backup Time At Half Load                              10 mins                                    10 mins                               10 mins
                                     Backup Time At Full Load                               4 mins                                     4 mins                               4 mins
                                     Charge Current 		                                                                           Internal battery: 1A
                                     Recharge Time		                                                                    90% capacity after 8 hours charging
  Environment                        Temperature		                                                                                  0°C to +40°C
                                     Relative Humidity		                                                                     0 – 95% (non-condensing)
                                     Altitude		                                                                                  1500m maximum
                                     Storage Temperature		                                                                         -25°C to +55°C
  Communication 			                                                                                          Standard: RS232, USB       Optional: SNMP or Relay Card
  LCD Display		                                                                  Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature
  		                                                                                                      Operation mode: On-line, Battery, Bypass
  LED Indication		                                                                Green LED: Normal operation              Yellow LED: Warning condition       Red LED: Abnormal operation
  Noise Level			                                                                                                                      < 45dBA
  Safety & EMC		                                                                      CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006
  Weight & Dimensions                Standard Unit Weight                                   12.0kg                                     21.1kg                                26kg
                                     Dimensions (H × W × D)                        400 × 380 × 86.5 mm                                               440 × 520 × 131 mm
  Standard Accessories               Control Software                                         Yes                                        Yes                                  Yes
                                     Input & Output Leads                                     Yes                                        Yes                                  Yes
                                     Data Lead                                                Yes                                        Yes                                  Yes
                                     User Manuals                                             Yes                                        Yes                                  Yes

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.
All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.




    Application
    Server,
    Telecommunications,
    Networking, Desktop,
    CCTV




                                                                                                                                                   www.dalepowersolutions.com            5
UPS catalogue 2015
E Series UPS Secure Power




          E200R+ Series
          An Advanced UPS Technology
          1:1 Phase | 1– 3 kVA | 0.9PF




    UPDATED
    Features
    3 High frequency, double conversion on-line
      technology
    3 Fully digital DSP control
    3 User friendly LCD interface
    3 Wide input voltage range
    3 Cold start function
    3 Advanced battery management
    3 Selectable Eco mode for high efficiency
      operation
    3 Automatic battery charge in UPS off mode
    3 Lightning and surge protection
    3 Short circuit and overload protection
    3 Automatic fan speed control with load variation
    3 Smart RS232 communications with monitoring
      software
    3 USB communications port included
    3 Optional relay or SNMP communications card
    3 Matching EER+ battery packs available
    3 Programmable load shedding in battery mode


                             Intelligent Slot options:
       BATTERY Pack          RELAY CARD                   SNMP card




                                                         OR




   6
UPS catalogue 2015
Specifications
  UPS Model		                                                                              E201R+                                     E202R+                                E203R+
  Capacity		                                                                           1000VA / 900W                              2000VA / 1800W                      3000VA / 2700W
  Input                               Voltage Range		                                                                           160V AC – 295V AC
                                      Phase 		                                                                                      Single phase
                                      Frequency		                                                            46 – 54Hz ±0.5Hz or 56 – 64Hz ±0.5Hz (auto sensing)
                                      Power Factor		                                                                                   >0.98
  Output                              Voltage		                                                                   200 / 208 / 220 / 230 / 240V AC ±2% (factory set)
                                      Phase		                                                                                       Single phase
                                      Frequency Range		                                                                          50 / 60Hz ±0.02Hz
                                      THD (Linear Load)		                                                                              < 3%
                                      THD (Non-Linear Load)		                                                                          < 5%
                                      Overload Capability		                                                        Up to 130% for 30 sec then transfer to bypass
  			                                                                                                             130% – 200% for 0.3 sec then transfer to bypass
  			                                                                                                                >200% for 0.2 sec then transfer to bypass
                                      Crest Factor		                                                                                 3:1 (max)
                                      Power Factor		                                                                                     0.9
                                      Short Circuit Protection                  On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm
  			                                                                                                Battery mode: Inverter turns off after 5 cycles & provides an alarm
  			                                                                                                   Bypass mode: AC input fuse blows or circuit breaker operates
                                      Waveform		                                                                                     Sine wave
                                      Transfer Time 		                                                             0ms (between on-line mode & battery mode)
                                      Efficiency		                                                                                ≥ 89% AC mode
  			                                                                                                                           ≥ 84% battery mode
  Battery                             Model		                                                                     12V valve regulated lead acid maintenance free
                                      DC Voltage                                            36V DC                                    72V DC                                72V DC
                                      Battery                                           3× 12V / 9Ah                                6× 12V / 9Ah                          6× 12V / 9Ah
                                      Backup Time At Half Load                              14 mins                                   14 mins                               8 mins
                                      Backup Time At Full Load                              5 mins                                     5 mins                               3 mins
                                      Charge Current 		                                                                                  1A
                                      Recharge Time		                                                                   90% capacity after 5 hours charging
  Environment                         Temperature		                                                                                 0°C to +40°C
                                      Relative Humidity		                                                                    0 – 90% (non-condensing)
                                      Altitude		                                                                                 1500m maximum
                                      Storage Temperature		                                                                        -25°C to +55°C
  Communication 			                                                                                          Standard: RS232, USB      Optional: SNMP or Relay Card
  LCD Display		                                                                  Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature
  		                                                                                                      Operation mode: On-line, Battery, Bypass
  LED Indication		                                                                Green LED: Normal operation             Yellow LED: Warning condition     Red LED: Abnormal operation
  Noise Level			                                                                                                                      < 55dBA
  Safety & EMC		                                                                       CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006
  Weight & Dimensions                 Standard Unit Weight                                  18.7kg                                     31.3kg                               33.0kg
                                      Dimensions (H × W × D)                       86.5 × 440 × 430 mm                                              86.5 × 440 × 690 mm
  Standard Accessories                Control Software                                         Yes                                      Yes                                   Yes
                                      Input & Output Leads                                     Yes                                      Yes                                   Yes
                                      Data Lead                                                Yes                                      Yes                                   Yes
                                      User Manuals                                             Yes                                      Yes                                   Yes

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.
All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.




    Application
    Server,
    Telecommunications,
    Networking, Desktop,
    CCTV




                                                                                                                                                 www.dalepowersolutions.com              7
UPS catalogue 2015
E Series UPS Secure Power




        E200+ Series
        An Advanced UPS Technology
        1:1 Phase | 1– 3 kVA | 0.9 PF




   Features
   3 High frequency, double
     conversion on-line technology
   3 Fully digital DSP control
   3 User friendly LCD interface
   3 Wide input voltage range
   3 Cold start function
   3 Advanced battery management
   3 Selectable ECO mode for high
     efficiency operation
   3 Automatic battery charge in UPS
     off mode
   3 Lightning and surge protection
   3 Short circuit and overload protection
   3 Automatic fan speed control with
     load variation
   3 Smart RS232 communications with
     monitoring software
   3 USB communications port included                       Intelligent Slot options:
   3 Optional relay or SNMP                  BATTERY PACK   RELAY CARD                   SNMP CARD
     communications card
   3 Matching EE+ battery packs available
   3 Programmable load shedding in
                                                                                        OR
     battery mode
   3 Emergency Power Off function




   8
Specifications
  UPS Model		                                                                               E201+                                     E202+                                 E203+
  Capacity		                                                                           1000VA / 900W                             2000VA / 1800W                         3000VA / 2700W
  Input                               Voltage Range		                                                                           160V AC - 295V AC
                                      Phase 		                                                                                     Single phase
                                      Frequency		                                                            46 – 54Hz ±0.5Hz or 56 – 64Hz ±0.5Hz (auto sensing)
                                      Power Factor		                                                                                   0.98
  Output                              Voltage		                                                                    200/208/220/230/240V AC ±2% (factory Set)
                                      Phase		                                                                                      Single phase
                                      Frequency Range		                                                             50 / 60Hz ±0.2% (auto selected at start up)
                                      THD (Linear Load)		                                                                             < 3%
                                      THD (Non-Linear Load)		                                                                         < 5%
                                      Overload Capability		                                                        Up to 130% for 30 sec then transfer to bypass
  			                                                                                                             130% - 200% for 0.3 sec then transfer to bypass
  			                                                                                                               >200% for 0.2 sec then transfere to bypass
                                      Crest Factor		                                                                                3:1 (max)
                                      Power Factor		                                                                                    0.9
                                      Short Circuit Protection                  On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm
  			                                                                                                Battery Mode: Inverter turns off after 5 cycles & provides an alarm
  			                                                                                                   Bypass mode: AC input fuse blows or circuit breaker operates
                                      Waveform		                                                                                    Sine wave
                                      Transfer Time 		                                                             0ms (between on-line mode & battery mode)
                                      Efficiency		                                                          ECO mode: ≥94% AC mode: ≥89% Battery mode: ≥84%
  Battery                             Model		                                                                     12V valve regulated lead acid maintenance free
                                      DC Voltage                                            36V DC                                   72V DC                                72V DC
                                      Battery                                            3x 12V / 9Ah                              6x 12V / 9Ah                          6x 12V / 9Ah
                                      Backup Time At Half Load                              14 mins                                  14 mins                                8 mins
                                      Backup Time At Full Load                              5 mins                                    5 mins                                3 mins
                                      Charge Current 		                                                                                 1A
                                      Recharge Time		                                                                  90% capacity after 5 hours charging
  Environment                         Temperature		                                                                                0°C to +40°C
                                      Relative Humidity		                                                                   0 – 95% (non-condensing)
                                      Altitude		                                                                         1500m maximum without derate
                                      Storage Temperature		                                                                       -25°C to +55°C
  Communication 			                                                                                          Standard: RS232, USB     Optional: SNMP or Relay Card
  LCD Display		                                                                  Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature
  		                                                                                                      Operation mode: On-line, Battery, Bypass
  LED Indication		                                                                Green LED: Normal operation            Yellow LED: Warning condition     Red LED: Abnormal operation
  Noise Level			                                                                                                                     < 55dBA
  Safety & EMC		                                                                       CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006
  Weight & Dimensions                 Standard Unit Weight                                  13.0kg                                    24.6kg                               25.5.0kg
                                      Dimensions (H × W × D)                        215 x 144 x 409 mm                                             337 x 199 x 466 mm
  Standard Accessories                Control Software                                         Yes                                     Yes                                   Yes
                                      Input & Output Leads                                     Yes                                     Yes                                   Yes
                                      Data Lead                                                Yes                                     Yes                                   Yes
                                      User Manuals                                             Yes                                     Yes                                   Yes

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.
All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.




    Application
    Server,
    Telecommunications,
    Networking, Desktop,
    CCTV




                                                                                                                                                www.dalepowersolutions.com               9
E Series UPS Secure Power




         E200 Series
         An Advanced UPS Technology
         1:1 Phase | 6 – 10 kVA | 0.8PF




                                                                    Features
                                                                    3 High frequency, double conversion on-line
                                                                      technology
                                                                    3 Fully digital DSP control
                                                                    3 Wide input voltage range
                                                                    3 Integral ‘hot-swap’ maintenance bypass module
                                                                    3 Cold start function
                                                                    3 Advanced battery management
                                                                    3 Selectable ECO mode for high efficiency operation
                                                                    3 Automatic battery charge in UPS off mode
                                                                    3 Lightning and surge protection
                                                                    3 Short circuit and overload protection
                                                                    3 Automatic fan speed control with load variation
                                                                    3 Parallel capacity or redundancy (maximum 4 units)
                                                                      requires a parallel card as factory fitted option
                                                                    3 Smart RS232 communications with monitoring
                                                                      software
                                                                    3 Optional relay or SNMP communications card
                                                                    3 Matching EE2000 battery packs available
                                                                    3 E suffix models have no internal battery and
                                                                      increased charging capacity
                                                                    3 Internal removable bypass switch




                            Intelligent Slot options:
       BATTERY pack         RELAY CARD                  SNMP card       Parallel card




  10
Specifications
  UPS Model 		                                                                         E206                               E206E                            E2010                         E2010E
  Capacity 		                                                                                     6000VA / 4800W                                                    10000VA / 8000W
  Input                               Voltage Range                                                                               120V AC – 276V AC
                                      Phase                                                                                          Single phase
                                      Frequency                                                                                         40 – 70Hz
                                      Power Factor                                                                                       ≥ 0.99
  Output                              Voltage                                                                                     220 / 230V AC ±2%
                                      Phase                                                                                          Single phase
                                      Frequency Range                                                                        50 / 60Hz (user adjustable)
                                      THD (Linear Load)                                                                                     ≤ 2%
                                      THD (Non-Linear Load)                                                                                 ≤ 6%
                                      Overload Capability                                                          ≤ 130% load for 10 min then transfer to bypass
  		                                                                                                                > 130% load for 1 sec then transfer to bypass
                                      Crest Factor                                                                                      3:1 (max)
                                      Power Factor                                                        0.7 (16 or 18× 12V batteries)           or   0.8 (20× 12V batteries)
                                      Short Circuit Protection                           On-line mode: ≥ 5 cycle duration, inverter turns off, no transfer to bypass, unit alarms
  		                                                                                      Battery mode: ≥ 5 cycle duration, inverter turns off, bypass unavailable, unit alarms
  		                                                                                                    Bypass mode: Input fuse blows or breaker operates, no alarm
                                      Waveform                                                                                          Sine wave
                                      Transfer Time                                                                 0ms (between on-line mode & battery mode)
                                      Efficiency                                                                                On-line mode: ≥ 90%
  Battery                             Model                                                                       12V valve regulated lead acid maintenance free
                                      DC Voltage                                     192V DC                       192 / 216 / 240V DC                    192V DC                  192 / 216 / 240V DC
                                      Battery                                     16× 12V / 9Ah                     16 / 18 / 20× 12V                  16× 12V / 9Ah                16 / 18 / 20× 12V
                                      Backup Time At Half Load                       14.3 min                 Depends on ext. battery                     6.5 min                Depends on ext. battery
                                      Backup Time At Full Load                        5.5 min                 Depends on ext. battery                     2.5 min                Depends on ext. battery
                                      Charge Current                                    1.0A                      1.0 – 6.0A (selectable)                   1.0A                  1.0 – 6.0A (selectable)
                                      Recharge Time                         90% capacity after 8 hrs          Depends on ext. battery             90% capacity after 8 hrs       Depends on ext. battery
  Environment                         Temperature                                                                                    0°C to +40°C
                                      Relative Humidity                                                                       0 – 95% (non-condensing)
                                      Altitude                                                                                    1500m maximum
                                      Storage Temperature                                                                           -25°C to +55°C
  Communication 		                                                                                           Standard: RS232       Optional: USB, SNMP or Relay Card
  LCD Display 		                                                                 Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature
  		                                                                                                      Operation mode: On-line, Battery, Bypass
  LED Indication 		                                                                Green LED: Normal operation             Yellow LED: Warning condition            Red LED: Abnormal operation
  Noise Level 		                                                                                                                        < 55dBA
  Safety & EMC 		                                                                     CE marked to 2006/95/EC & 2004/108/EC                 Tested to EN62040-1-1:2003 & EN62040-2:2006
  Weight & Dimensions                 Standard Unit Weight                 77kg (nett) / 84 kg (gross) 35kg (nett) / 42kg (gross) 80kg (nett) / 87kg (gross) 38kg (nett) / 45kg (gross)
                                      Dimensions (H × W × D) mm               655 × 250 × 590 mm                  655 × 250 × 590 mm
  Standard Accessories                Control Software                                                                                      Yes
                                      Input & Output Leads                                                                          Optional extra
                                      Battery Leads                                                                                 Optional extra
                                      Data Lead & User Manual                                                                               Yes

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.
All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.




                                                                                                                                      Internal removable bypass switch


    Application
    Server,
    Telecommunications,
    Networking, Desktop,
    CCTV




                                                                                                                                                       www.dalepowersolutions.com                  11
E Series UPS Secure Power




        E200R Series
        An Advanced UPS Technology
        3:1 or 1:1 | 6 – 10 kVA | 0.9PF




   Features
   3 High frequency, double conversion on-line
     technology
   3 Input can be configured for either 3:1 or 1:1
     operation
   3 Rotatable LCD – suitable for 19" rack or slim
     tower
   3 Fully digital DSP control
   3 Wide input voltage range
   3 Cold start function
   3 Advanced battery management
                                                                                  BATTERY pack
   3 Selectable ECO mode for high efficiency
     operation
   3 Automatic battery charge in UPS off mode
   3 Lightning and surge protection
   3 Short circuit and overload protection
   3 Automatic fan speed control with load
     variation
   3 Up to 4 units can be operated in parallel       Intelligent Slot options:
   3 Smart RS232 communications with                 RELAY CARD                   SNMP card
     monitoring software
   3 USB communications port included
   3 Optional relay or SNMP communications card
                                                                                 OR
   3 Matching EER2000 battery pack available




  12
Specifications
  UPS Model		                                                                                        E21306RE		E21310RE
  Capacity		                                                                                      6000VA / 5400W		                                            10000VA / 9000W
  Input                               Rated Voltage		                                                               380 / 400 / 415V AC or 220 / 230 / 240V AC
                                      Voltage Range		120V AC – 276V AC Line – Neutral or 208V AC – 478V AC Line – Line
                                      Phase 		                                                                    3 Phase 4 Wire & Earth or 1 Phase 2 Wire & Earth
                                      Frequency		                                                                                    40 – 70Hz
                                      Power Factor		                                                                                   ≥0.99
  Output                              Voltage		                                                                              220 / 230 / 240V AC ±2%
                                      Phase		                                                                                      Single phase
                                      Frequency Range		                                                                 50 / 60Hz ± 0.2Hz (user adjustable)
                                      THD (Linear Load)		                                                                              ≤ 2%
                                      THD (Non-Linear Load)		                                                                          ≤ 5%
   Overload Capability AC Mode: ≤110% for 3 min, ≤125% for 30 sec, ≤150% for 1 sec,
  			 >150% shutdown immediately, transfer to bypass
                                                                                Battery Mode: ≤110% for 30 sec, ≤125% for 1 sec, ≤150% for 0.2 sec, >150% shutdown immediately
                                      Crest Factor		                                                                                 3:1 (max)
                                      Power Factor		                                                                                    0.9
                                      Short Circuit Protection		                                                                        Yes
                                      Waveform		                                                                                    Sine wave
                                      Transfer Time 		                                                             0ms (between on-line mode & battery mode)
                                      Efficiency		                                                                             On-line mode: ≥ 90%
  Battery                             Model		                                                                     12V valve regulated lead acid maintenance free
                                      DC Voltage		                                                                              192 / 216 / 240V DC
                                      Backup Time At Half Load
                                                                                                                     Depends on the external battery capacity
                                      Backup Time At Full Load
                                      Charge Current 		                                                                           6A (Maximum)
                                      Recharge Time		                                                                90% capacity after 8 – 10 hours charging
  Environment                         Temperature		                                                                                0°C to +40°C
                                      Relative Humidity		                                                                   0 – 95% (non-condensing)
                                      Altitude		                                                                                 1500m maximum
                                      Storage Temperature		                                                                       -25°C to +55°C
  Communication 			Standard: USB, RS485 & Parallel Port                                                                                               Optional: SNMP or Relay Card
  LCD Display		                                                                  Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature
  		                                                                                                      Operation mode: On-line, Battery, Bypass
  LED Indication		                                                                Green LED: Normal operation             Yellow LED: Warning condition       Red LED: Abnormal operation
  Noise Level			                                                                                                                     < 55dBA
  Safety & EMC			 CE marked to EN62040-1-1:2008 & EN62040-2:2006
  Weight & Dimensions                 Standard Unit Weight                                              23.0kg		25.0kg
                                      Dimensions (H × W × D) 		                                                                131 × 443 × 580 mm
  Standard Accessories                Control Software                                                    Yes		                                                      Yes
                                      Input & Output Leads                                                Yes		                                                      Yes
                                      Data Lead                                                           Yes		Yes
                                      User Manuals                                                        Yes		Yes
                                      Battery Leads                                                Optional extra		                                             Optional extra

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.
All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.




    Application
    Server,
    Telecommunications,
    Networking, Desktop,
    CCTV




                                                                                                                                                  www.dalepowersolutions.com            13
E Series UPS Secure Power




          E200 Series
          An Advanced UPS Technology
          3:1 Phase | 10 –20kVA | 0.8PF




   Features
   3 High frequency, double conversion
     on-line technology
   3 Fully digital DSP control
   3 Wide input voltage range
   3 Integral ‘hot-swap’ maintenance bypass
     module on E2310(E) model
   3 Cold start function
   3 Advanced battery management
   3 Selectable ECO mode for high efficiency
     operation
   3 Automatic battery charge in UPS off mode
   3 Lightning and surge protection
   3 Short circuit and overload protection
   3 Automatic fan speed control with
     load variation
   3 Parallel capacity or redundancy
     (maximum 4 units) requires a parallel
     card as factory fitted option
   3 Smart RS232 communications with
     monitoring software
   3 Optional relay or SNMP communications
     card
   3 Matching EE2000 battery packs available
     for E2310(E) model




       Intelligent Slot options:
       RELAY CARD                  SNMP card    Parallel card




  14
Specifications
  UPS Model		                                                                             E2310E                                    E2315E                                  E2320E
  Capacity		                                                                       10000VA / 8000W                           15000VA / 12000W                        20000VA / 16000W
  Input                               Voltage Range                                                                     176V AC to 275V AC Line – Neutral
                                      Phase                                                                                   3 Phase 4 Wire & Earth
                                      Frequency                                                                                     40 – 70Hz
                                      Power Factor                                                                                    ≥ 0.99
  Output                              Voltage                                                                                  220 / 230V AC ±2%
                                      Phase                                                                                        Single phase
                                      Frequency Range                                                                       50 / 60Hz (user adjustable)
                                      THD (Linear Load)                                                                               ≤ 2%
                                      THD (Non-Linear Load)                                                                           ≤ 6%
                                      Overload Capability                                                         ≤ 130% load for 10 min then transfer to bypass
  		                                                                                                               > 130% load for 1 sec then transfer to bypass
                                      Crest Factor                                                                                  3:1 (max)
                                      Power Factor                                                        0.7 (16 or 18× 12V batteries)      or   0.8 (20× 12V batteries)
                                      Short Circuit Protection                           On-line mode: ≥ 5 cycle duration, inverter turns off, no transfer to bypass, unit alarms
  		                                                                                      Battery mode: ≥ 5 cycle duration, inverter turns off, bypass unavailable, unit alarms
  		                                                                                                    Bypass mode: Input fuse blows or breaker operates, no alarm
                                      Waveform                                                                                      Sine wave
                                      Transfer Time                                                                0ms (between on-line mode & battery mode)
                                      Efficiency                                                                              On-line mode: ≥ 90%
  Battery                             Model                                                                       12V valve regulated lead acid maintenance free
                                      DC Voltage                                                                               192 / 216 / 240V DC
                                      Battery                                                                                16 / 18 / 20× 12V blocks
                                      Backup Time At Half Load                                                             Depends on external battery
                                      Backup Time At Full Load                                                             Depends on external battery
                                      Charge Current                                                                          1.0 – 6.0A (selectable)
                                      Recharge Time                                                                        Depends on external battery
  Environment                         Temperature                                                                                  0°C to +40°C
                                      Relative Humidity                                                                     0 – 95% (non-condensing)
                                      Altitude                                                                                  1500m maximum
                                      Storage Temperature                                                                         -25°C to +55°C
  Communication 		                                                                                           Standard: RS232     Optional: USB, SNMP or Relay Card
  LCD Display		                                                                  Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature
  		                                                                                                      Operation mode: On-line, Battery, Bypass
  LED Indication		                                                                Green LED: Normal operation            Yellow LED: Warning condition       Red LED: Abnormal operation
  Noise Level		                                                                                                                      < 55dBA
  Safety & EMC		                                                                      CE marked to 2006/95/EC & 2004/108/EC            Tested to EN62040-1-1:2003 & EN62040-2:2006
  Weight & Dimensions                 Standard Unit Weight                                  40kg                                      45kg                                   45kg
                                      Dimensions (H × W × D) mm                                         655 × 250 × 590 mm                                            655 × 250 × 590 mm
  Standard Accessories                Control Software                                                                                 Yes
                                      Input & Output Leads                                                                        Optional extra
                                      Battery Leads                                                                               Optional extra
                                      Data Lead & User Manual                                                                          Yes

Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.
All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.




    Application
    Server,
    Telecommunications,
    Networking, Desktop,
    CCTV




                                                                                                                                                  www.dalepowersolutions.com            15
E Series UPS Secure Power




         E300 Series
         An Advanced UPS Technology
         3:3 Phase | 10 – 250kVA | 0.8PF




    UPDATED
   Features
   3 High frequency double conversion on-line UPS
   3 Fully digitised microprocessor control
   3 Parallel capacity or redundancy
     (maximum 4 units)
   3 Wide input voltage range from single or dual
     source
   3 Open architecture design provides full access
     for servicing
   3 Intelligent battery charge management
   3 RS232/RS485 communication with monitoring
     software
   3   Short circuit and overload protection
   3   Over temperature and over humidity protection
   3   EMI and RFI noise filtering
   3   ECO Mode
   3   User friendly LCD interface
   3   Cold start and programmable auto re-start
       functions (optional extra)
   3 Fan speed auto control with load variation
   3 Built-in static and maintenance bypass switches
   3 Back feed protection between UPS output and
     mains supply
   3 Emergency Power Off function
   3 Low THD & high input power factor for diverse
     generator compatibility
                                                       Intelligent Slot options:
   3 Soft start with programmable power walk-in        relay card                  SNMP card
   3 Optional temperature compensated battery
     charging
   3 Optional SNMP, relay card and remote
     monitoring panel
   3 Optional galvanic isolation transformer
   3 Nicad battery option available




  16
The Dale E300 series is the innovative new generation of high frequency, on-line double conversion Uninterruptible Power Supplies.
Full DSP controlled inverter technology ensures continuous, clean, true sinusoidal power to critical applications under a wide
range of conditions. Available in output power capacities from 10 to 250kVA, all with three phase input and output. Innovative and
inspired in concept, designed and manufactured with engineering precision to deliver pure, resilient power to the most critical of
applications.


  Common Specifications

  Input                                Voltage Range                                                                       176V AC to 264V AC Line-Neutral
                                       Phase                                                                                       3 Phase 4 Wire & Earth
                                       Frequency                                                                           50 / 60Hz ±10% (user adjustable)
                                       Power Factor                                                                                         > 0.99
  Output                               Voltage                                                                     220 / 230V AC Line-Neutral (user adjustable)
                                       Phase                                                                                       3 Phase 4 Wire & Earth
                                       Frequency range                                                                           50 / 60Hz (user adjustable)
                                       THD (Linear Load)                                                                                     < 2%
                                       THD (Non-Linear Load)                                                                                 < 3%
                                       Efficiency                                                                        On-line mode: 93%           ECO mode: 98%
                                       Overload Capacity                                                               125% load for 10 min, 150% load for 1 min
                                       Crest Factor                                                                                           3:1
                                       Power Factor                                                                                           0.8
                                       Short Circuit Protection                                                          IGBT controlled electronic protection
                                       Waveform                                                                                        True sine wave
                                       Transfer Time                                                                                0ms (on-line mode)
  Battery                              External                                                                   Up to 50 x 12V mono blocks (600V DC Nominal)
  Environment                          Altitude                                                                                    1000m at rated power
                                       Operate Temperature                                                                              0°C to 40°C
                                       Relative Humidity                                                                         0 – 95% (non-condensing)
  Communication		                                                                        Standard: RS232 / RS485            Optional: SNMP and relay cards, remote monitoring panel
  LCD Screen Display		                                                           Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature
  		                                                                                                      Operation mode: On-line, Battery, Bypass
  LED Indication		                                                                                   Double conversion on-line or ECO line interactive (user selectable)
  		                                                                                                       Mimic panel overview of UPS operation and alarms
  Noise Level
E Series UPS Secure Power




   E300 Series                                                                                                     x  4
DSP Power Factor Corrected                       Automatic adjustment of charging              The static switch contains electronically
IGBT Rectifier                                   parameters based on the battery               controlled switching circuits that enable
                                                 configuration entered via the LCD panel.      the critical load to be connected to either
IGBT power factor correction technology
                                                                                               the inverter output or to a bypass source
provides an input power factor close
                                                 Real-time battery management information      via the static bypass line. During normal
to unity (≥0.99) and input current total
                                                 is displayed on the LCD, such as battery      operation, the load is connected to the
harmonic distortion (THDi) less than 3%
                                                 capacity (as percentage or time remaining).   inverter, but in the event of a UPS overload
to avoid disturbances to the connected
                                                                                               or inverter failure, the load is automatically
loads.
                                                 Temperature compensated battery charging      transferred to the static bypass line.
                                                 monitors are available to monitor the
The high input power factor leads to
                                                 internal and external battery temperature     To provide a clean (no-break) load transfer
reduced electricity consumption, minimised
                                                 with a feedback control loop to adjust the    between the inverter output and static
switchgear and circuit protection, cabling
                                                 charge current rate accordingly.              bypass line, the static switch activates
and generator requirements, thus reducing
                                                                                               and connects the load to bypass. To
investment cost.
                                                 Programmable automatic or manual              achieve this, the inverter output and
                                                 battery tests can be performed without        bypass are fully synchronised by the
Parallel and Redundant                           interruption to the UPS operation or load.    inverter control electronics.
Operation
Capability to connect up to 4 units in           DSP Controlled IGBT Inverter                  Manual Bypass
parallel to provide increased power capacity                                                   This feature is provided solely to allow
                                                 The DSP controlled IGBT inverter provides
or redundancy. All parallel units can be                                                       maintenance work to be carried out on
                                                 a clean, true sine wave output voltage
operated from the front panel of any UPS.                                                      the UPS without interrupting the power to
                                                 to deliver the highest quality power to
                                                                                               the load. The UPS can be powered down
                                                 protect critical loads.
Power Increase                                                                                 to enable technical personnel to replace
Units can be connected in parallel to increase                                                 parts. Full system replacement and repair
                                                 The DSP circuitry is embedded within a
the total capacity of the system. When an                                                      of major components does however,
                                                 single control board to reduce hardware
inverter goes offline, the critical loads are                                                  necessitate shutdown of the load.
                                                 and improve noise immunity. Complex
automatically transferred to bypass.             control algorithms are utilised with
                                                 floating point controllers to ensure          Optional Single or Dual Source
Redundancy                                       uninterrupted operation and protection        Operation
Units can be connected in parallel               of the loads in abnormal conditions that      To increase flexibility, the UPS input can
to provide redundancy for absolute               may cause failure.                            be fed by single or dual sources. In dual
reliability. In parallel redundant mode, the
                                                                                               configuration, the rectifier is fed from the
number of units (N) supply the load and          The DSP control system achieves fast          utility (main source), and the static and
an extra unit is provided in case of failure     dynamic response for non-linear loads         maintenance bypasses are fed from a
(N+1). All units share the load current          and high power factor under various load      secondary source.
equally. When a unit goes offline, due           conditions.
to failure or maintenance, the standby
unit continues to supply the critical load                                                     Open Architecture Design
                                                 Static & Manual
without any interruption.                                                                      The UPS incorporates an open architecture
                                                 (Maintenance) Bypass
                                                                                               design to facilitate full access to replace
Advanced Battery Management Static and manual bypass switches are                              parts quickly and easily, resulting in low
                                                 included as standard, with operational        Mean Time To Repair (MTTR).
Intelligent precision charging principles
                                                 characteristics as follows:
guarantee enhanced battery life and
maximum battery performance and                                                                Diverse Generator
                                                 Static Bypass
reliability. This provides the reassurance
                                                 This feature provides a safe transfer to      Compatibility
that the battery is primed and ready for
                                                 mains should the UPS be overloaded or         Thanks to the robust IGBT rectifier, the E300
the critical role they play in your power
                                                 develop a fault condition.                    series UPS is uniquely compatible with a
protection system.
                                                                                               diverse range of sources, in particular,




    18
generators. Input current total harmonic           With reduced THDI and high 0.99 input           Advanced Communications
distortion (THDi) of less than 3% is               power factor, switchgear, circuit protection,   A wide range of advanced communication
achieved without compromising efficiency.          cabling and generator requirements are          options are available:
The high input power factor enables a              minimised, thus reducing investment cost.
generator to be utilised with a power                                                              External Battery
rating only 20% higher than the UPS.               Advanced User Interface                         Temperature Sensor
                                                   The UPS operating information and               One module is fitted to each external
Power walk-in can be adjusted from 5 to 15                                                         battery cabinet to monitor the battery
                                                   parameter settings are displayed in 4
seconds. Based on the current measured                                                             temperature. A feedback control loop within
                                                   different languages and can be accessed
on the input, the UPS gradually increases                                                          the UPS adjusts the charge current based
                                                   using the large user friendly, data rich LCD
the power supplied from the utility source                                                         on the battery temperature, optimising
                                                   and system LED mimic panel. The UPS is
to the load. The power, delivered by the utility                                                   battery performance and longevity.
                                                   capable of recording up to 500 events.
source to the load, varies according to the
input voltage, current and power factor.                                                           Relay Alarms Card
                                                   Green ECO Mode of Operation
                                                                                                   Isolated, volt-free dry contacts indicate the
Back Feed Protection                               The E300 series UPS can be operated in          UPS operating status and the presence of
                                                   high efficiency ECO mode (98%) providing        alarm conditions. Fully programmable to
Back feed protection prevents current
                                                   green energy savings through reduced            facilitate the capture of a diverse range
from the UPS output feeding back to the
                                                   power consumption.                              of operating and alarm conditions.
UPS input terminals, thereby protecting
maintenance personnel from electric                                                                Opto-isolated inputs allow the UPS to be
shock hazards whilst working on the                Emergency Power Off (EPO)                       controlled remotely.
incoming supply side of the system.                The EPO function is designed to switch off
                                                   the UPS in an emergency situation (eg. fire,    RS232/RS485 Serial Port
Reverse Energy Tolerance                           flood). Operation of the EPO turns off the      The UPS operating parameters can be
                                                   rectifier and inverter and cuts power to the    observed and controlled locally using an
for Regenerative Loads
                                                   load immediately (both the inverter and         RS232/RS485 communications port. Real
The E300 series UPS is suitable for use with       bypass lines). The EPO also prevents the        time notification of changes in UPS status
regenerative loads, such as synchronous            battery from charging or discharging.           is reported to users by SMS or e-mail.
motors. Regenerative loads pump energy
back to the mains supply. Traditionally, UPS       With the utility input supply present, the      SNMP Network Card
systems would burn this feedback energy,           UPS control circuits remain energised,          Enables monitoring and control of the
resulting in lower operating efficiency.           even though the output is turned off.           UPS operation by ethernet or internet
The IGBT rectifier in the E300 series UPS is       To remove all power from the UPS, the           connection. Allows the remote execution
capable of absorbing intermittent load             external feeder breaker must be opened.         of scheduled events and the shutdown
generated power. This reverse power                                                                / reboot of the UPS and multiple servers.
tolerance facilitates the execution of                                                             Full event log and data management. Real
                                                   Auto Re-start
important system operations, such as                                                               time notification of changes in UPS status
closed transition transfers of the UPS load        When the utility and bypass sources fail, the   reported to users by audible alarm, SMS or
directly to an engine generator source.            UPS draws power from the battery system         e-mail. Software supports Windows, Linux,
                                                   to supply the load, until the batteries are     Mac, Solaris, Open VMS and IBM operating
Lower Total Cost of Ownership                      depleted. Once the batteries reach their        systems.
                                                   End of Discharge threshold, the UPS will
The high efficiency operation of the UPS           shut down. The UPS will automatically
means that less energy is consumed to                                                              Remote LCD and LED Mimic Panel
                                                   re-start once the utility power is restored     Facilitates the monitoring and control of
supply power to the protected loads. As a          and output power to the load will be
result of reduced heat emission and power                                                          the UPS operations, events and parameters
                                                   delivered. The UPS also incorporates a          from a remote location.
loss, users benefit from reduced electricity       programmable automatic start time delay.
usage and air conditioning requirements.



   Application
   Server, Telecommunications,
   Networking, Data Centre,
   IT, Financial, Emergency
   Services, Defence, Retail,
   Transportation, Broadcasting
   and Communications,
   Healthcare, Leisure and Sport,
   Government, Education



                                                                                                       www.dalepowersolutions.com        19
E Series UPS Secure Power




        E600 Series
        An Advanced UPS Technology
        1:1, 3:1, 3:3 Phase | 10 – 200kVA | 0.9PF


                                                   UP TO


                                               96%
    UPDATED                                      Efficiency
                                                   at half load




   Features
   3 Hot swappable modular design
   3 Flexible and expandable UPS
     power solution
   3 19" cabinets available in full
     and half height format
   3 Modular design capable of housing
     either 5× or 10× power modules
   3 Power modules available in 10
     and 20kVA ratings
   3 Configurable N+1 modular
     redundancy
   3 Parallel system capability
     (maximum 4x cabinets)
   3 High frequency double conversion
     on-line technology
   3 Wide input voltage range
   3 Intelligent battery charge
     management
   3 Programmable battery charge
     current
   3 Short circuit and overload protection
   3 EMI and RFI noise filtering
   3 Smart RS232 communication with
     monitoring software
   3 Fully digitised microprocessor control
                                                                  Intelligent Slot options:
   3 Large touch screen LCD interface
                                              BATTERY Pack        RELAY CARD                  SNMP
   3 Built-in maintenance bypass
   3 Emergency Power Off function
   3 Optional SNMP card or relay card
   3 Optional hot plug internal batteries




  20
The Dale E600 series UPS is a sophisticated, new generation of modular, high frequency on-line double conversion Uninterruptible
Power Supplies. Full DSP controlled inverter technology ensures continuous, clean, true sine wave power to critical applications
under a wide range of conditions. Available in output power capacities from 10 to 200kVA in 1:1 and 3:1 phase configurations and
10 to 100kVA in 3:3 phase configuration. The E600 series UPS is the perfect modular UPS solution, capable of supporting a diverse
range of mission critical applications.

  Specifications

  Cabinet Model		                                                                             E61150		                             E63150                E631100                 E633100                 E633200
  Maximum Rating		                                                                          10 – 50kVA		                         10 – 50kVA             10 – 100kVA             10 - 100kVA            10 - 200kVA
  		                                                                                         8 – 40kW		                           8 – 40kW               8 – 80kW                 9 – 90kW              9 – 180kW
  Input                                Voltage range                             120 to 276V AC Line - Neutral                   220 / 230V AC Line - Neutral                   380 / 400 / 415 AC Line - Line
                                       Phase                                         1 Phase 2 Wire & Earth                          3 Phase 4 Wire & Earth                          3 Phase 4 Wire & Earth
                                       Frequency                                                                                             40 – 70Hz
                                       Power factor                                                                                             ≥0.99
  Output                               Voltage                                    220 / 230V AC Line – Neutral                   220 / 230V AC Line – Neutral                  380 / 400 / 415V AC Line – Line
                                       Phase                                          1 Phase 2 Wire & Earth                         1 Phase 2 Wire & Earth                          3 Phase 4 Wire & Earth
                                       Frequency range                                                                                        50-60Hz
                                       THD                                                                           ≤2% with linear load ≤5% with non-linear load
                                       Efficiency                                                                                      Utility mode > 90%
    Overload capability
E Series UPS Secure Power




   E600 Series
                                                                                                                x   4
DSP Power Factor Corrected                      Advanced Battery Management Static Bypass
IGBT Rectifier                                                                                This feature provides a safe transfer to
                                                Intelligent precision charging principles
                                                                                              mains should the UPS be overloaded or
Latest IGBT power factor correction             guarantee enhanced battery life and
                                                                                              develop a fault condition.
technology provides an input power              maximum battery performance and
factor close to unity (≥0.99) and input         reliability. This provides the reassurance
                                                                                              The static switch contains electronically
current total harmonic distortion (THDi)        that the battery is primed and ready for
                                                                                              controlled switching circuits that enable
less than 3% to avoid disturbances to the       the critical role they play in your power
                                                                                              the critical load to be connected to either
connected loads.                                protection system.
                                                                                              the inverter output or to a bypass source
                                                3 Powerful 6A charger built into each         via the static bypass line. During normal
N+X Parallel Modular                              UPS module with the ability to freely       operation, the load is connected to the
Redundancy                                        set the charge current level.               inverter, but in the event of a UPS overload
The E600 series provides N+X parallel           3 Automatic adjustment of charging            or inverter failure, the load is automatically
modular redundancy for absolute                   parameters based on the battery             transferred to the static bypass line.
reliability. When a module goes offline,          configuration settings.
due to failure or maintenance, the                                                            To provide a clean (no-break) load transfer
                                                3 Real-time battery management infor-
remaining modules continue to supply                                                          between the inverter output and static
                                                  mation is displayed on the LCD, such as
the load without any interruption.                                                            bypass line, the static switch activates and
                                                  battery capacity (as percentage or time
                                                                                              connects the load to bypass. To achieve
                                                  remaining).
The level of redundancy can be set to suit                                                    this, the inverter output and bypass are
                                                3 Programmable automatic or manual            fully synchronised by the inverter control
the criticality of the protected load. Should
                                                  battery tests can be performed without      electronics.
the load increase above the redundancy
                                                  interruption to the UPS operation or
threshold, the UPS will alarm to notify the
                                                  load. The batteries can also be ‘hot-
user there is insufficient capacity available
                                                  swapped’ without disconnection of           This feature is provided solely to allow
to maintain the load if a module fails.
                                                  the UPS.                                    maintenance work to be carried out on
This allows preventative action to be
taken (decrease load or install additional                                                    the UPS without interrupting the power to
UPS modules).                                   Single or Dual Source Operation               the load. The UPS can be powered down
                                                For increased flexibility, the E600 series    to enable technical personnel to replace
High Availability & MTBF                        UPS is available with a split bypass,         parts. Full system replacement and repair
All UPS modules share the load current          enabling the UPS input to be fed by single    of major components does however,
equally. With two modules configured            or dual sources. In dual configuration,       necessitate shutdown of the load.
for redundancy, the UPS system achieves         the rectifier is fed from the utility (main
99.999% availability and the Mean               source) and the static and maintenance        Cold Start Operation
Time Before Failure (MTBF) exceeds              bypass are fed from a secondary source.       When the utility and bypass sources
15,000,000 hours, satisfying the reliability                                                  are not available, the cold start feature
requirements of the critical load.              Scalable Modular Solution                     enables the UPS to be started using the
                                                1.4m and 2.0m tall 19” cabinets are           battery only.
The UPS design incorporates ‘drawer style’
                                                available, capable of holding up to 5 or
hot-swap UPS modules to facilitate quick                                                      Excellent Generator
                                                10 UPS modules respectively, providing
and easy replacement for low Mean Time
                                                scalability to expand as power demand         Compatibility
To Repair (MTTR).
                                                increases. Up to 4 three phase cabinets may
                                                                                              Thanks to the robust IGBT rectifier, the
                                                be connected in parallel configuration,
DSP Controlled IGBT Inverter                    providing a maximum output power
                                                                                              E600 series UPS is compatible with a
                                                                                              diverse range of sources, including
The DSP controlled IGBT inverter provides       capacity of 800kVA at 0.9 power factor.
                                                                                              generators. High Input power factor
a clean, true sine wave output voltage
                                                                                              (0.99) and low input current total
to deliver the highest quality power to         Static & Manual                               harmonic distortion (THDi)
Adjustable power walk-in allows the UPS         system LED mimic panel. The UPS stores          RS232 Serial Port
to gradually increase the power supplied        500 events on a rolling data log.               The UPS operating parameters can be
from the utility source to the load, based                                                      observed and controlled locally using an
on the current measured on the input.           Emergency Power Off (EPO)                       RS232 communications port.
                                                The EPO function is designed to switch
Module Options available                        off the UPS in an emergency situation (eg.
                                                                                                SNMP Network Card
                                                                                                Enables monitoring and control of the UPS
3U high ‘drawer-style’ UPS modules with         fire, flood). Operation of the EPO turns off
                                                                                                operation by LAN or Internet connection
individual LCD control panel. Available         the rectifier and inverter and cuts power
                                                                                                and allows the remote execution of
in the following phase and power                to the load immediately (both the inverter
                                                                                                scheduled events and the shutdown/
configurations:                                 and bypass lines). The EPO also prevents
                                                                                                reboot of the UPS and multiple servers.
3 1:1 Phase – 10kVA                             the battery from charging or discharging.
                                                                                                Full event log and data management.
3 3:1 Phase – 10kVA                                                                             Real time notification of changes in UPS
                                                With the utility input supply present, the
                                                                                                status reported to users by SMS or e-mail.
3 3:3 Phase – 10 and 20kVA                      UPS control circuits remain energised,
                                                                                                Software supports Windows, Linux, Mac,
                                                even though the output is turned off.
                                                                                                Free BSD and VM Ware operating systems.
Common module size:                             To remove all power from the UPS, the
                                                                                                Accepts environmental monitoring inputs
H131 × W443 × D580mm                            external feeder breaker must be opened.
                                                                                                (temperature, humidity, water, smoke,
                                                                                                security sensors).
Decentralised Parallel                          Auto Re-start
Structure Concept                               When the utility and bypass sources fail,       Green ECO Mode of Operation
Each UPS module contains all the required       the UPS draws power from the battery
                                                                                                The E600 series UPS can be operated in
hardware and software for autonomous            system to supply the load, until the
                                                                                                high efficiency ECO mode (98%) providing
operation, without reliance on the              batteries are depleted. Once the batteries
                                                                                                green energy savings through reduced
centralised monitoring module. This             reach their End of Discharge threshold,
                                                                                                power consumption.
increases system reliability by eliminating     the UPS will shut down. Once the utility
Single Points of Failure (SPOF).                and bypass sources are re-instated, the
                                                UPS will auto re-start, deliver power to the    Centralised Monitoring Module
Lower Total Cost of Ownership                   load and recharge the battery.                  All system data is processed by a centralised
                                                                                                monitoring module offering advanced
The high efficiency operation of the UPS
                                                Advanced Communications                         DSP control technology. The module itself
(≤ 98% in ECO mode and ≤96% in On-Line                                                          can be exchanged from the system
mode) means that less energy is consumed        A wide range of advanced communication
                                                                                                without disrupting the protected load.
to supply power to the protected loads.         options are available:
As a result of reduced heat emission and
                                                Relay Alarms Card                               Hot swappable modules
power loss, users benefit from reduced
electricity usage and air conditioning          Isolated, volt-free dry contacts indicate the   Hot swappable modules allows for modules
requirements.                                   UPS operating status and the presence of        to be removed whilst the system is live for
                                                alarm conditions. Opto-isolated inputs          ease of servicing or repair, this removes
With low
E Series UPS Secure Power




        E700 Series
        An Advanced UPS Technology

        3:3 Phase | 10 – 40kVA | 0.9PF




   *NEW             to the E Series Range




   Features
   3 High frequency, double conversion
     on-line technology
   3 Fully digital microprocessor control
   3 Parallel capacity or redundancy
     (maximum 4 units)
   3 Wide input voltage range
   3 Intelligent battery charge
     management
   3 Automatic battery charge in UPS
     off mode
   3 RS232 communication with
     monitoring software
   3 Short circuit and overload protection
   3 Lightning and surge protection
   3 EMI and RFI noise filtering
   3 Line interative ECO Mode
   3 User friendly LCD interface
   3 Cold start function
   3 Built-in maintenance bypass switch
   3 Emergency Power Off function
   3 Relay alarm card fitted as standard
   3 Optional SNMP network card
     available
   3 Supplied with 36x 38Ah VRLA
                                             Intelligent Slot options:
     battery as standard
                                                    RELAY CARD           SNMP
   3 Alternative battery capacity /
     autonomy available




  24
The Dale E700 UPS is a state-of-the-art high frequency, double conversion on-line uninterruptible power supply with internal sealed
VRLA battery, providing exceptionally high performance levels. Available in output power capacities of 10kVA, 15kVA, 20kVA, 30kVA
and 40kVA, all with three phase input and output. The E700 series has been engineered to protect critical loads and processes that
could be disrupted by power quality power or an unexpected break in the utility supply.


  Specifications

  UPS Model 		                                                                   E73310B                     E73315B                 E73320B                E73330B                 E73340B
  Capacity 		                                                                      10KVA                          15KVA                20KVA                     30KVA              40KVA
  		                                                                                9KW                       13.5KW                   18KW                      27KW               36KW
  Input                               Voltage Range 			184V AC to 276V AC Line-Neutral
                                      Phase                                                                                     3 Phase 4 Wire & Earth
                                      Frequency                                                                                       40 – 70Hz
                                      Power Factor                                                                                      ≥ 0.99
  Output                              Voltage                                                                      220/230/240V AC Line-Neutral (user adjustable)
                                      Phase                                                                                     3 Phase 4 Wire & Earth
                                      Frequency Range                                                                         50 / 60Hz (user adjustable)
                                      THD (Linear Load)                                                                                  ≤ 2%
                                      THD (Non-Linear Load)                                                                              ≤ 5%
                                      Waveform                                                                                        Sine wave
                                      Overload Capability                                ≤110%: 60 mins, ≤125%: 10 mins, ≤150%: 1 min, ≥150% automatic shutdown of UPS
                                      Crest Factor                                                                                    3:1 (max)
                                      Power Factor 		                                                                                     0.9
                                      Short Circuit Protection                                                                           Yes
                                      Transfer Time                                                                                      0ms
                                      Efficiency                                                                     On-line mode: ≥95% Battery mode: ≥93%
  Battery                             Type                                                                         12V valve regulated lead acid maintenance free
                                      DC Voltage                                                                     384V - 480V DC (432V DC fitted as standard)
                                      Battery 		                                                                                    36x 12V / 38Ah
                                      Backup Time At Half Load                     150 min                        90 min               60 min                    35 min              25min
                                      Backup Time At Full Load                     60 min                         35 min               25 min                    12 min               8 min
                                      Charge Current 		                                                                               6A (max)
                                      Recharge Time 		Charge current can be set according to battery capacity installed
  Environment                         Temperature                                                                                    0°C to 40°C
                                      Relative Humidity                                                                       0 – 95% (non-condensing)
                                      Altitude                                                                                    1500m maximum
                                      Storage Temperature                                                                           -25°C to 55°C
  Communication 		                                                                                                         Standard: RS232      Optional: SNMP
  LCD Display 		                                                             Measurements: Input/output voltage/frequency, battery voltage, load power and kVA, UPS temperature
  		                                                                                                     Operation mode: On-line, Battery, Bypass
  LED Indication 		                                                                Green LED: Normal operation              Yellow LED: Warning condition        Red LED: Abnormal operation
  Noise Level 		                                                                                                                       < 55dBA
  Safety & EMC 		                                                                         CE marked. Tested to EN/IEC 62040-1-1, EN/IEC62040-2, EN/IEC60950-1, IEC6100-4
  Weight & Dimensions                 Standard Unit Weight                          600kg                         602kg                 604kg                    606kg		 608kg
                                      Dimensions (H × W × D) mm			 1200 x 600 x 780 mm
  Standard Accessories                Relay alarm card			                                                                          Fitted as standard
                                      SNMP network card                                                                             Optional extra



Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability.
All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing.




                                                                                                                                                    www.dalepowersolutions.com              25
E Series UPS Secure Power




   E700 Series
                                                                                                                     x   4
DSP Power Factor Corrected                        Back Feed Protection                             to the static bypass line. To provide a clean
IGBT Rectifier                                                                                     (no-break) load transfer between the
                                                  Back feed protection prevents current
                                                                                                   inverter output and static bypass line, the
Latest IGBT power factor correction               from the UPS output feeding back
                                                                                                   static switch activates and connects the
technology provides an input power                to the UPS input terminals, thereby
                                                                                                   load to bypass. To achieve this, the inverter
factor close to unity (≥0.99) and input           protecting maintenance personnel from
                                                                                                   output and bypass are fully synchronised
current total harmonic distortion (THDi)          electrocution whilst working on the
                                                                                                   by the inverter control electronics.
less than 3% to avoid disturbances to the         incoming supply side of the system.
connected loads.                                                                                   MANUAL BYPASS
                                                  Advanced Battery Management This feature is provided solely to allow
DSP control system                                Intelligent precision charging principles        maintenance work to be carried out on
The digital signal processor controls the         guarantee enhanced battery life and              the UPS without interrupting the power to
power-on, star-up, input power factor             maximum battery performance and                  the load. The UPS can be powered down
control, battery charging, output stage ac        reliability. This provides the reassurance       to enable technical personnel to replace
voltage regulation and shutdown control           that the battery is primed and ready for         parts. Full system replacement and repair
for the UPS system.                               the critical role they play in your power        of major components does however,
                                                  protection system. Automatic adjustment          necessitate shutdown of the load.
Parallel and Redundant                            of charging parameters based on the
Operation                                         battery configuration entered via the LCD        Discrete UPS Module Design
                                                  panel. Real-time battery management              The UPS design incorporates discrete rack
Capability to connect up to 4 units in parallel   information is displayed on the LCD, such
to provide increased power capacity or                                                             mounted UPS module to facilitate quick
                                                  as battery capacity (as percentage or time       and easy replacement for low Mean Time
redundancy. As each UPS contains and              remaining). Programmable automatic or
internal battery, an increase in autonomy                                                          To Repair (MTTR). The UPS module can
                                                  manual battery tests can be performed            be exchanged with the protected load
time is also achieved when units are              without interruption to the UPS operation
connected in parallel. Automatic master/                                                           supplied by the internal maintenance
                                                  or load.                                         bypass breaker.
slave rotation is provided for additional
reliability.
                                                  DSP Controlled IGBT Inverter
                                                                                                   Frequency Converter Mode
POWER INCREASE                                    The DSP controlled IGBT inverter provides
                                                                                                   The UPS can also be used as a frequency
Units can be connected in parallel to increase    a clean, true sine wave output voltage to
                                                                                                   converter. It can accept a 40Hz to 70Hz
the total capacity of the system. When an         deliver the highest quality power to protect
                                                                                                   input frequency range and provide a stable
inverter goes offline, the critical loads are     critical loads.
                                                                                                   50Hz or 60Hz output frequency.
automatically transferred to bypass.
                                                  Static & Manual
                                                                                                   Excellent Generator
REDUNDANCY                                        (Maintenance) Bypass
Units can be connected in parallel                                                                 Compatibility
                                                  Static and manual bypass switches are
to provide redundancy for absolute                                                                 Thanks to the robust IGBT rectifier, the E700
                                                  included as standard, with operational
reliability. In parallel redundant mode, the                                                       series UPS is compatible with a diverse range
                                                  characteristics as follows:
number of units (N) supply the load and                                                            of sources, including generators. High Input
                                                  STATIC BYPASS
an extra unit is provided in case of failure                                                       power factor (0.99) and low input current
                                                  This feature provides a safe transfer to
(N+1). All units share the load current                                                            total harmonic distortion (THDi)
Lower Total Cost of Ownership                  Discharge threshold, the UPS will shut          Free BSD and VM Ware operating systems.
                                               down. The UPS can be programmed to              Accepts environmental monitoring inputs
The high efficiency operation of the UPS
                                               auto-recover after End of Discharge after a     (temperature, humidity, water, smoke,
(>95% in on-line mode) means that less
                                               set variable delay time.                        security sensors).
energy is consumed to supply power to
the protected loads. As a result of reduced
heat emission and power loss, users benefit    Cold Start Operation
from reduced electricity usage and air         When the utility source is not available, the
conditioning requirements. With low
E Series UPS Secure Power




        E800 Series
        An Advanced UPS Technology
        3:3 Phase | 10–600kVA | 0.8PF




   *NEW             to the E Series Range




   Features
   3 Cutting edge technology, high frequency double
     conversion on-line UPS
   3 Fully digital microprocessor control
   3 Parallel capacity or redundancy (maximum 4 units)
   3 Wide input voltage and frequency range
   3 Dual input as standard on 80kVA models and above
   3 Open architecture design provides full access for servicing
   3 Intelligent battery charge management
   3 RS232/RS485 communication with monitoring software
   3 Short circuit and overload protection
   3 Over temperature and over humidity protection
   3 EMI and RFI noise filtering
   3 Line interactive ECO mode
   3 Large user friendly LCD interface
   3 Cold start and programmable auto re-start functions
   3 Fan speed auto control with load variation
   3 Built-in static and maintenance bypass switches
   3 Back feed protection between UPS output and
     mains supply
   3 Emergency Power Off function
   3 Low THD and high input power factor for diverse
     generator compatibility
   3 Soft start with programmable power walk-in
   3 Optional temperature compensated battery charging             Intelligent Slot options:
                                                                   relay card                  SNMP card
   3 Optional SNMP, relay card and remote monitoring panel




  28