Médecine du Sport Sports Medicine - Chirurgies du Genou, de l'Epaule et des Petites Articulations Knee, Shoulder and Small Joints Surgeries - CliniLab
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
Médecine du Sport Sports Medicine Chirurgies du Genou, de l’Epaule et des Petites Articulations Knee, Shoulder and Small Joints Surgeries
Instabilité et Réparation de la Coiffe des Rotateurs Instability, Rotator Cuff Suture of Shoulder Fully Threaded Titanium Suture Anchor Ancre Titane Reference Diameter Needles Suture Ti Anchor TIAN-0351 3.5 mm 4 needles 900 mm x 2 TIAN-0501 5.0 mm 4 needles 900 mm x 2 TIAN-0651 6.5 mm 4 needles 900 mm x 2 TIAN-0350 3.5 mm No needle 900 mm x 2 TIAN-0500 5.0 mm No needle 900 mm x 2 TIAN-0650 6.5 mm No needle 900 mm x 2 Caractéristiques Characteristics Les ancres Titane Noraker sont composées de Titane Ti-6-Al- Noraker Titanium anchors are composed of Titanium Ti-6-Al- 9(/,PDWpULDXDYHFXQHH[FHOOHQWHELRFRPSDWLELOLWp/HV¿OV 4V 5Eli, material with excellent biocompatibility. The sutures in de suture en Polyéthylène à Haut Poids Moléculaire (UHMWPE) Ultra High Molecular Weight Polyethylene (UHMWPE) provide DVVXUHQW OD ¿[DWLRQ GHV WLVVXV HQ WRXWH VpFXULWp /HV DQFUHV D VDIH ¿[DWLRQ LQ WKH WLVVXHV 1RUDNHU 7LWDQLXP DQFKRUV DUH 7LWDQH 1RUDNHU VRQW HQWLqUHPHQW ¿OHWpHV SRXU PD[LPLVHU fully threaded to maximize the insertion of the device into the l’insertion du dispositif dans l’os. Le design est adapté aux bone. The design is suitable for arthroscopic and mini-open chirurgies arthroscopiques et mini-open. surgeries. %pQp¿FHV %HQH¿WV - Excellente biocompatibilité - Excellent biocompatibility - Sutures souples et résistantes - Soft and resistant sutures - Facile à manipuler - Easy handling - Sécurité d’utilisation - Safety use Fully Threaded PEEK Suture Anchor Ancre PEEK Reference Diameter Needles Suture Fibers PEEK Anchor PKAN-0291 PKAN-0351 2.9 mm 3.5 mm 4 needles 4 needles 900 mm x 2 900 mm x 2 Suture Suture PKAN-0501 5.5 mm 4 needles 900 mm x 2 Suture PKAN-0651 6.5 mm 4 needles 900 mm x 2 Suture PKAN-0290 2.9 mm No needle 900 mm x 2 Suture PKAN-0350 3.5 mm No needle 900 mm x 2 Suture PKAN-0500 5.5 mm No needle 900 mm x 2 Tape PKAN-0650 6.5 mm No needle 900 mm x 2 Tape PKAN-0291 2.9 mm 4 needles 900 mm x 2 Tape PKAN-0351 3.5 mm 4 needles 900 mm x 2 Tape Caractéristiques PKAN-0501 5.5 mm 4 needles 900 mm x 2 Tape Les ancres PEEK Noraker sont des dispositifs à visser, PKAN-0651 6.5 mm 4 needles 900 mm x 2 Tape DVVRFLpHV j GHV ¿OV GH VXWXUH HQ 3RO\pWK\OqQH j +DXW PKAN-0290 2.9 mm No needle 900 mm x 2 Tape Poids Moléculaire (UHMWPE) pour une implantation en PKAN-0350 3.5 mm No needle 900 mm x 2 Tape toute sécurité. PKAN-0500 5.5 mm No needle 900 mm x 2 Tape Les ancres PEEK Noraker sont adaptées aux chirurgies arthroscopiques et mini open. PKAN-0650 6.5 mm No needle 900 mm x 2 Tape Characteristics %pQp¿FHV %HQH¿WV Noraker PEEK anchors are screw devices, associated - Excellente biocompatibilité - Excellent biocompatibility with surgical sutures in Ultra High Molecular Weight - Sutures souples et résistantes - Soft and resistant sutures 3RO\HWK\OHQH 8+0:3( IRUDVDIH¿[DWLRQLQWKHWLVVXHV Noraker PEEK anchors are suitable for arthroscopic and - Facile à manipuler - Easy handling mini-open surgeries. - Sécurité d’utilisation - Safety use |6|
Instabilité et Réparation de la Coiffe des Rotateurs Instability, Rotator Cuff Suture of Shoulder Caractéristiques Characteristics Les sutures chirurgicales non résorbables FixFiber ® FixFiber® surgical sutures are made in Ultra High VRQW GHV ¿OV HQ 3RO\pWK\OqQH j +DXW 3RLGV 0ROpFXODLUH Molecular Weight Polyethylene (UHMWPE). The breading (UHMWPE). Le tressage est réalisé avec différentes is a patented technology that combine colored strand couleurs selon une technologie brevetée, associé à des and needles. The penetration of FixFiber® is improved by aiguilles perforantes. La pénétration de FixFiber® est ainsi 12%.3 améliorée de 12%.3 %pQp¿FHV %HQH¿WV - Résistance mécanique : risque de rupture minimisé3 - Mechanical resistance, reducing the risk of breakage - Visibilité garantie dans le site opératoire, gain en during surgery3 HI¿FDFLWp *XDUDQWHHGYLVLELOLW\LQVXUJLFDOVLWHLPSURYLQJHI¿FDF\ - Insertion optimisée3 - Optimal insertion3 - Ligature facilitée3 - Ease ligature3 - Suture chirurgicale plate disponible - Flat braid reference available FixFiber™, Non Absorbable Suture Reference USP Size Length Description 900 Fil droit avec 2 aiguilles : 1 Demi-cercle ronde 26 mm, 1 Demi-cercle triangulaire 36 mm 800 FixFiber NOR-HS900 #2 900 mm Straight suture with 2 needles: + 18 % 1 round half circle 26mm, 700 1 triangular half circle 36 mm Market Leader Fil boucle avec 1 aiguille 600 triangulaire en demi-cercle 36 mm Tensile Strength (N) NOR-HS902 #2 245 mm Closed suture with 1 needle 500 triangular half circle 36 mm 400 FixFiber + 36 % 300 Market Leader Fil plat d’une largeur de 2,2mm NOR-HS963 # 2.2 990 mm Flat suture, width of 2.2mm 200 100 Double Buttoned Rope 0 KNOT PULL STRAIGHT PULL Reference USP Size Length Description *UDSK0HFKDQLFDOUHVLVWDQFHFRPSDULVRQRQÀDWEUDLGSURGXFWV Double bouton pour réparation disjonction acromio-claviculaire KRDB-3070 70 mm Double buttoned rope for acromio- clavicular disjonction repair Double bouton pour réparation disjonction acromio-claviculaire KRDB-3090 90 mm Double buttoned rope for acromio- clavicular disjonction repair |8|
Reconstruction Ligamentaire des Petites Articulations Ligament Reconstruction in Small Joints Surgeries Ancre Titane Fully Threaded Titanium Suture Anchor Ti Anchor Reference TIAN-0201 Diameter 2.0 mm Needles 2 needles Suture 900 mm x 1 TIAN-0351 3.5 mm 4 needles 900 mm x 2 TIAN-0200 2.0 mm No needle 900 mm x 2 TIAN-0350 3.5 mm No needle 900 mm x 2 Les ancres Titanium NORAKER sont composées NORAKER Titanium anchors are made of GH7LWDQHHWGH¿OVGHVXWXUHHQSRO\pWK\OqQH Titanium and sutures in Ultra High Molecular à Haut Poids Moléculaire (UHMWPE), pour Weight Polyethylene (UHMWPE), to safely DVVXUHUOD¿[DWLRQGHVWLVVXVHQWRXWHVpFXULWp provide tissue traction. &DUDFWpULVWLTXHVHWEpQp¿FHVSDJH &KDUDFWHULVWLFVDQG%HQH¿WVSDJH Ancre PEEK Fully Threaded PEEK Suture Anchor Reference Diameter Needles Suture PEEK Anchor PKAN-0291 2.9 mm 4 needles 900 mm x 2 PKAN-0351 3.5 mm 4 needles 900 mm x 2 PKAN-0290 2.9 mm No needle 900 mm x 2 PKAN-0350 3.5 mm No needle 900 mm x 2 Les ancres PEEK NORAKER sont associées à NORAKER PEEK anchors are associated with GHV¿OVGHVXWXUHHQSRO\pWK\OqQHj+DXW3RLGV surgical sutures in Ultra High Molecular Weight Moléculaire (UHMWPE) pour une implantation Polyethylene (UHMWPE) for safe implantation. en toute sécurité. &KDUDFWHULVWLFVDQG%HQH¿WVSDJH &DUDFWpULVWLTXHVHWEpQp¿FHVSDJH Ancre Tissu All Suture Anchor (supplied with single use drill) SOFT Anchor Reference YKAN-0121 Diameter 1.2 mm Needles 2 needles Suture 900 mm x 2 YKAN-0151 1.5 mm 4 needles 900 mm x 2 YKAN-0120 1.2 mm No needle 900 mm x 2 YKAN-0150 1.5 mm No needle 900 mm x 2 Les ancres en tissu NORAKER sont des NORAKER Soft Anchors consist of Ultra High dispositifs en polyéthylène à Haut Poids Molecular Weight Polyethylene (UHMWPE) Moléculaire (UHMWPE), pour une meilleure device, to allow a better integration in the implantation dans le tunnel osseux. bone tunnel. &DUDFWpULVWLTXHVHWEpQp¿FHVSDJH &KDUDFWHULVWLFVDQG%HQH¿WVSDJH | 10 |
Médecine du Sport Sports Medicine 1. Hench L. The story of Bioglass, Journal of FixLoop et Fixloop+, système d’ancrage tendineux Materials Science: Materials in Medicine (2006) et ligamentaire de classe IIb, CE0459. FixFiber, 17:967-978 suture non résorbable de classe III, CE0459. 2. EP1967160 Dispositifs indiqués pour la reconstruction des ligaments et tendons. Ancres chirurgicales, de 3. 'DWDRQ¿OHVDW0DQXIDFWXUHU classe IIb, CE1984, indiquées dans la chirurgie de 4. Landes, C.A., Ballon A. and Roth C., In-patient l’épaule et des petites articulations. versus in vitro degradation of P(L/DL)LA and LockActiv™ (distribuée exclusivement par la PLGA, Journal of Biomedical Materials Research société Innovaker) : vis d’interférence résorbables Part B: Applied Biomaterials (2006) 76(2):403- de classe III, marquées par GMED CE0459 et 11 indiquées pour la reconstruction des ligaments 5. Middleton J.C., Tipton A.J., Synthetic croisés du genou. biodegradable polymers as orthopedic devices, Dispositifs inscrits sur la liste LPPR : 8113531, Biomaterials (2000), 21(23):2335-2346 8113614, 8113637. Lire attentivement les notices d’utilisation. 6. Weiler, A., Hoffmann R.F. et al., Hamstring WHQGRQ ¿[DWLRQ XVLQJ LQWHUIHUHQFH VFUHZV FixLoop and Fixloop+, tendon and ligament class a biomechanical study in calf tibial bone, IIb anchoring system, CE0459. FixFiber, class III Arthroscopy: The Journal of Arthroscopic and non-absorbable suture, CE0459. Devices indicated Related Surgery (1998) 14(1):29-37 for the reconstruction of ligaments and tendon. 7. Joerg, W., In Vitro degradation and strength Surgical anchors, class IIb, CE1984, indicated in retention of high-molecular weight poly(L-lactide- shoulder and small joints surgery. co-D,L-lactide) 70:30 (2002) - Boehringer-Evonik LockActiv ™ (distributed exclusively by Innovaker): 8. Bostman O., Clinical biocompatibility class III absorbable interference screws, have of biodegradable orthopaedic implants for been marked with GMED CE0459 and are indicated LQWHUQDO ¿[DWLRQ D UHYLHZ %LRPDWHULDOV for the knee cruciate ligaments reconstruction. 21(24):2615-2621 Carefully read the use instructions. 60, Av. Rockefeller 69008 Lyon France Tél : +33 (0)4 78 93 30 92 Fax : +33 (0)4 72 35 94 37 contact@noraker.com www.noraker.com 2.1-SPOR-Brochure-FR&EN-2.4 10/2020
You can also read