BEYOND PAIN - www.fremslife.com

Page created by Gilbert Pena
 
CONTINUE READING
BEYOND PAIN - www.fremslife.com
BEYOND PAIN

Immediate benefit
Simplicity
Rapidity

www.fremslife.com
BEYOND PAIN - www.fremslife.com
Musculoskeletal pain is the effect and/or
the main cause of disability
         is aimed at treating MUSCULOSKELETAL pain and reducing dysfunctions that
are often secondary to such painful conditions by offering an original, patented ultra-low
power Laser emission – now better known as PHOTOBIOMODULATION – to be applied
on sequences of points derived from acupuncture experience.

        acts quickly on acute and chronic pain: a valuable aid for manual and
instrumental rehabilitation techniques.

Since musculoskeletal pain is one of the main causes of motor and balance dysfunctions,
        treats musculoskeletal pain and related dysfunctions and can therefore play an
important role in functional recovery by reducing the Risk of accidental Falls.

The Intended Use
of Libralux is for the
following treatments
     musculoskeletal pain and related dysfunctions;
     relaxing or toning the musculoskeletal system*;
     sores, ulcers and scar tissue
     similar to Traditional Chinese Medicine (TCM)* Acupuncture
     treatments. These treatments must be performed:
     - in clinics that comply with the applicable regulations;
     - by personnel who have the necessary skills and
        qualifications (Doctor or Physiotherapist), duly trained
        in the specific method.

(*) These treatments and those similar to Traditional Chinese Medicine Acupuncture treatments, which are described in the user
    manual, can be performed under the operator’s responsibility and are not covered by the CE Certificate issued by the Notified Body
    code 1936 for the Libralux product.
BEYOND PAIN - www.fremslife.com
it is a medical device and it features:

    Simplicity of application
    Rapidity of execution
    Immediate benefit for the patient

                                                  MODULAZIONE 1

                                                       +
                                                                            By means of an
                                                  MODULAZIONE 2
                                                                            extremely low frequency
                                                       +
                                                                            laser beam extremely effective bio-stimulation
                                                  MODULAZIONE 3             is produced, thanks to a particular combination
                                                       =                    (patented) of wavelength, modulation and power.
                                                  MODULAZIONE               The emission also includes low frequency
                                                   RISULTANTE
                                                                            modulation against tissue habituation.

Simplicity                                                                  Rapidity
The selections of protocols and, in sequence, all                           The Physical features of the beam (wave length,
the points to be stimulated with their anatomical                           modulation and power) are automatically adapted
picture are shown on the touch screen display:                              as specifically needed in order to stimulate each
                                                                            point.

                                                                            Immediate benefits
                                                    Musculoskeletal pain is
                                                    always associated with
                                                    an imbalance of the
                                                    physiological state.
                                                    This imbalance causes
                                                    a change in the state
                                                    of the Extracellular
• general rebalancing treatment, indicated also for matrix that alters the
  preparatory purposes in a number of painful clin- interaction between
  ical conditions*;                                 the organs and tissues.

• treatment of ulcer, skin sores, scars;              Thanks to its specific
• specific treatment for musculoskeletal pain in dif- patented photonic stimulation algorithm,
  ferent body areas and for motor or balance disor-              restores the correct “respiratory”
  ders associated with them.                          cycle of the extracellular matrix proteins.

(*) T his treatment and those similar to Traditional Chinese Medicine Acupuncture treatments, which are described in the user manual, can be performed
    under the operator’s responsibility and are not covered by the CE Certificate issued by the Notified Body code 1936 for the Libralux product.
BEYOND PAIN - www.fremslife.com
Numerous clinical and laboratory re-              Lorenzini L, Giuliani A, Giardino L, Calzà L.                                                                                                                                        Baratto L, Capra R, Farinelli M, Monteforte P,
search projects confirm the effectiveness         Laser acupuncture for acute inflammatory,                                                                                                                                            Morasso P, Rovetta G. Sonographic exam-
of          , also in treating disorders          visceral and neuropathic pain relief: An ex-                                                                                                                                         ination in patient with osteorathritis of the
secondary to pain itself:                         perimental study in the laboratory rat. Res                                                                                                                                          cervical spine reveals soft-tissues chang-
                                                  Vet Sci. 2010 Feb;88(1):159-65.                                                                                                                                                      es due to apllication with very low-power
Giuliani A, Fernadez M, Farinelli M, Baratto L,   Baratto L, Calzà L, Capra R, Gallamini M,                                                                                                                                            modulated laser. Int J Clin Pharmacol Res.
Capra R, Rovetta G, Monteforte P, Giardino L,     Giardino L, Giuliani A, Lorenzini L, Traverso S.                                                                                                                                     2000;20 (1-2):13-6
Calzà L. Very low level laser therapy attenu-     Ultra-low-level laser therapy. Lasers Med                                                                                                                                            Bergamaschi M, Ferrari G, Gallamini M,
ates edema and pain in experimental mod-          Sci. 2011 Jan;26(1):103-12                                                                                                                                                           Scoppa F. Laser acupuncture and auricu-
els. Int. J.Tissue React. 2004;26 (1-2):29-37     Petruzzelli S, Congiu A, Gallamini M, Pom-                                                                                                                                           lotherapy in postural instability - a prelimi-
Giuliani A, Fernandez M, Giardino L, Calzà L,     pei R. Ultra-low power laser stimulation                                                                                                                                             nary report.              J Acupunct Meridian
Farinelli M, Baratto L, Capra R. Peripher-        impairs the adhesion of Staphylococcus                                                                                                                                               Stud. 2011 Mar;4(1):69-74.
al Stimulation For Pain Treatment Pathos.         aureus to primary human cells, and inter-                                                                                                                                            Gallamini M. Treating balance disorders by
2003; 10 (4): 115-9                               feres with the expression of staphylococcal                                                                                                                                          ultra-low-level laser stimulation of acupoints.
Giuliani A, Lorenzini L, Gallamini M, Massel-     pathogenic factors. New Microbiol. 2014                                                                                                                                              J Acupunct Meridian Stud. 2013 Apr;6(2):119-
la A, Giardino L, Calzà L. Low infra red laser    Apr;37(2):193-9.                                                                                                                                                                     23.
light irradiation on cultured neural cells: ef-   Giuliani A, Lorenzini L, Alessandri M, Torricel-                                                                                                                                     Vanzini M, Gallamini M, Amblyopia: Can
fects on mitochondria and cell viability after    la R, Baldassarro VA, Giardino L, Calzà L. In                                                                                                                                        Laser Acupuncture Be an Option? Journal of
oxidative stress. BMC Complement Altern           vitro exposure to very low-level laser modi-                                                                                                                                         Acupuncture and Meridian Studies. (2016),
Med. 2009 Apr 15;9:8.                             fies expression level of extracellular matrix                                                                                                                                        doi: 10.1016/j.jams.2016.01.017.
                                                  protein RNAs and mitochondria dynamics                                                                                                                                               Evangelista L, De Meo B, Bernabei G, et al.
                                                  in mouse embryonic fibroblasts. BMC Com-                                                                                                                                             Ultra-Low-Level Laser Therapy and Acu-
                                                  plement Altern Med. 2015 Mar 24;15:78.                                                                                                                                               puncture Libralux: What Is so Special? Med-
                                                  Monteforte P, Baratto L, Molfetta L, Rovetta G.                                                                                                                                      icines (Basel). 2019;6(1):40
                                                  Low-power Laser in osteoarthritis of the                                                                                                                                             Vanzini M, Gallamini M. Laser Acupuncture
                                                  cervical spine. Int J Tissue React 2003;25(4):                                                                                                                                       in Open-Angle Glaucoma Treatment: A Ret-
                                                  131-6                                                                                                                                                                                rospective Study of Eye Blood Flow. J Acu-
                                                                                                                                                                                                                                       punct Meridian Stud. 2020;13(2):40-47

                                                     SPECIFICATIONS
                                                     Laser therapy device                                                                                                                                                                                     LIBRALUX
                                                     AC Main Power Supply MeanWell GSM18B05-P1J                                                                                                                                                               Output 5 Vdc, 15 W
                                                     Laser                                                                                                                                                                                                    Class 2
                                                     Red light emission - Wavelength                                                                                                                                                                          655 nm
                                                     Peak power                                                                                                                                                                                               7 mW
                                                     Mean Output power                                                                                                                                                                                        0,0175 mW
                                                     Touchscreen Display                                                                                                                                                                                      7’’
                                                     Certified according to EEC 93/42                                                                                                                                                                         Class IIa
                                                     Laser classified according to EN 60825                                                                                                                                                                   Class 2

                                                                             Fremslife is certified ISO 13485 (standing Ed.)
                                                                             LIBRALUX is CE Certified compliant to EEC 63/42 (Annex V)

                                                                                                                                                                  www.imq.it

                                                                                                                                     CERTIFICATO N.
                                                                                                                                     CERTIFICATE N. 9124.BIOT

                                                                                                                   SI CERTIFICA CHE IL SISTEMA DI GESTIONE PER LA QUALITA’ DI
                                                                                                             WE HEREBY CERTIFY THAT THE QUALITY MANAGEMENT SYSTEM OPERATED BY

                                                                                                                                                         FREMSLIFE SRL
                                                                                                                                     VIA BUCCARI 9 - 16153 GENOVA (GE)

                                                                                                                                           UNITA' OPERATIVE / OPERATIVE UNITS

                                                                                                                                     VIA BUCCARI 9 - 16153 GENOVA (GE)

                                                                                                                  E' CONFORME ALLA NORMA / IS IN COMPLIANCE WITH THE STANDARD
                                                                                                                                                         ISO 13485:2016
                                                                                                                       PER LE SEGUENTI ATTIVITA' / FOR THE FOLLOWING ACTIVITIES

                                                                               Progettazione, produzione, immissione in commercio e assistenza di elettrostimolatori neuromuscolari e
                                                                                relativi elettrodi, apparecchi per diatermia e aghi monouso sterili per stimolazione elettrica percutanea
                                                                              Design, production, placing on the market and servicing of neuromuscular electrical stimulators and related
                                                                              electrodes, equipments for diathermy and sterile single use needles for percutaneous electrical stimulation

                                                                                           Ulteriori informazioni riguardanti l'applicabilità dei requisiti ISO13485:2016 possono essere ottenute consultando l'organizzazione
                                                                                           Further clarifications regarding the applicability of ISO 13485:2016 requirements may be obtained by consulting the organization

                                                                                                                             IL PRESENTE CERTIFICATO E' SOGGETTO AL RISPETTO DEL
                                                                                                                          REGOLAMENTO PER LA CERTIFICAZIONE DEI SISTEMI DI GESTIONE
                                                                                                                       THE USE AND THE VALIDITY OF THE CERTIFICATE SHALL SATISFY THE
                                                                                                                   REQUIREMENTS OF THE RULES FOR CERTIFICATION OF MANAGEMENT SYSTEMS

                                                                                              DATE:                    PRIMA CERTIFICAZIONE                                                          EMISSIONE CORRENTE   SCADENZA
                                                                                                                       FIRST CERTIFICATION                                                           CURRENT ISSUE         EXPIRY
                                                                                                                       2008-09-26                                                                   2020-07-24            2023-09-10

                                                                                                                                       _________________________
                                                                                                                                       IMQ S.p.A. - VIA QUINTILIANO, 43 - 20138 MILANO ITALY
                                                                                                                                                      Management Systems Division - Flavio Ornago
                                                                                                                                                                                                                                                                                         DEP LX_Eng_rev.01

                                                                                  SGQ N° 005 A
                                                                                                                        La validità del certificato è subordinata a sorveglianza annuale e riesame completo
                                                                                  Membro degli Accordi di Mutuo         del Sistema di Gestione con periodicità triennale
                                                                                  Riconoscimento EA, IAF e ILAC         The validity of the certificate is submitted to annual audit and a reassessment
                                                                                  Signatory of EA, IAF and ILAC         of the entire management System within three years
                                                                                  Mutual Recognition Agreements

                                                                                                                                                                                                                                       Fremslife s.r.l.
                                                                                                                                                                                                                                       Via Buccari 9
                                                                                                                                                                                                                                       16153 Genova
                                                                                                                                                                                                                                       Tel: +39 010 6402911
                                                                                                                                                                                                                                       Fax: +39 010 6402900

                                                                                                                                                                                                                                       Email: info@fremslife.com