Active Optical Components - braun teleCom
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
As a supplier of broadband communication Further to our HFC and FTTX product lines, consisting
technology braun teleCom has stood for c ompetence of active and passive components, we have continually
and continuity for more than 30 years. With our expanded our range by successfully integrating
long experience and constantly growing know-how sophisticated services into our portfolio.
we have become a leading supplier of systems and
system components for HFC and FTTX broadband We have set highest quality standards for our entire range
networks. of products and services, while ensuring that we offer the
best possible price-performance ratio to our customers.
While, in many areas, our activities focus on the
development and production of our own products, braun teleCom is part of the BTV Multimedia Group.
we also serve as distributor for selected high Our aim as a leading value-added supply partner is
performance cooperation partners to achieve best to provide our customers with the best products and
possible customer satisfaction. services in the broadband industry.Point-to-point technology
network service approaches supported by Waystream components
MPC
Customer VLAN Access (L2)
802.1Q
• Each residential home or business is connected to a port that is assigned Trunk
to a unique C-VLAN.
• Set of C-VLANs are bridged to through the aggregation layer to a broad-
band network gateway (BNG), such as the Waystream MPC480.
• Service control in the network is often done through RADIUS based
authorization to the MPC, but other commercial automation solutions are Vid 101 Vid 103
also common to adapt network configuration for individual customers
subscription.
Vid 102
Service-VLAN Access
• All end-users using the same service/category of service are part of the
same VLAN. Service control is typically done on the port of the access
switch connecting the end-user instead of at a central BNG.
• Service-VLANs often span across mulitple switches in the access and Access network
aggregation layers.
• The service-VLANs are layer 3 terminated in a layer 3 switch or edge
router, but no advanced service features are applied here – standard
routing is sufficient if the service control has already been done at the
access-layer.
• Several commercial options for automation exist, often using the
command line interface of the access switch to set and remove
configuration as services are updated. B
A
D C
Service VLAN 100
Service VLAN 101
Layer 3 Routed Access Core
• Access-swiches route the traffic all the way to the access ports that
connect the end-users.
• Each user is connected on a port that is separated by routing.
• The end-user is connected without any VLANs to the home/office router Access
or switch – it is a plain layer 2 domain.
• Main advantages are load-sharing through routing over multiple links, fast
Subject to technical changes!
redundancy and easy network operation (tools such as ping and trace
route can be used).
1MS8000
10 Gbit/s access switch for FTTH/FTTB
The MS8000 Ethernet switch is purpose built for FTTH/FTTB access to the network lets you reduce operational cost and save time when dealing
enable easy operation and deployment of services. with network issues.
The MS8000 provides you with a feature set to support demanding business The MS8000 meets network operator needs for long deployment cycles and
and residential services such as Internet, TV, wholesale capacity services and reliable network operation and it is purpose built with fiber networks in mind
private networks at the same time as simplified and automated control of to support a wide variety of network architectures and service models.
Parameter MS8024 MS8048
Uplink ports 4 1000/10000base-X (SFP+) 4 1000/10000base-X (SFP+)
Downlink ports 24 1/10G (SFP+ fiber) / 2.5G (SFP copper) 48 1/10G (SFP+ Fiber) / 2.5G (SFP copper)
Standard iBOS Standard
Dimensions (H x W x D) [mm] 43 x 441 x 240
Weight [kg] 4
Interface LED indicator for link and speed, dual color
Indicators Power LED indicator
System LED indicator
Redundant fan, sufficient cooling capacity even with one fan failing,
Cooling
Commercial temp: Front-to-side airflow
Operating temperature [°C] 0 – 45
Operating humidity, non-condensing [%] 10 – 90
AC: One IEC 60320-1 C14, located on the front panel
Power connector
One 12 V DC connector located on the back panel for external power supply
AC: Front-panel AC power input 100-240V, 50/60 Hz to internal PSU
Power
Rear-panel 12 V DC power input to mainboard
Power consumption (room temperature) [W] 35 85
Switch ASIC performance Forwarding bandwidth: 160 Gbps, 240 Mbps
NPU Performance 1.200 MHz NPU with 4 cores, providing up to 10 Gbps throughput
MAC table 16.000 MAC addresses
VLAN table 4.094 VLANs
Multicast S, G entries 2.048 L2 multicast, 4.000 IP multicast groups
IP spoofing protection, Up to 10 Gbps bandwidth IP fragment inspection in NPU,
Security Restricted multicast access with IGMP join-filter, UNI isolated ports, MAC Forced Forwarding,
DHCPv4 snooping for anti-spoofing
Interface mirroring to local interface
Mirroring
Interface mirroring over GRE to remote Wireshark or other packet capture tool
Command Line Interface Industry standard CLI with debugging, configuration and management, Telnet, SSH
Serial interface RS232 console serial port to access CLI
SNMP SNMPv1, v2c and v3
Subject to technical changes!
PacketFront Device protocol exchange system information with other iBOS devices
PFDP
and selected PFNP customer premise equipment
Management
System boot BOOTP client for address assignment
Time NTP time synchronisation
Remote logging Syslog
LLDP Link Layer Discovery Protocol
Telemetry Streaming telemetry as InfluxDB line-protocol HTTP or JSON over TCP
on request
Order No.
Pease contact us to find a solution meeting your demands.
2 MS8000Product overview Customer and service VLAN topologies
• Layer 2 access switch designed for FTTx access networks, network aggre- • The MS8000 can be used in a wide variety of network topologies and
gation and traffic classification and prioritization to deliver the ultimate supports:
user experience • Ethernet wholesale with C-VLAN and S-VLAN, supporting double-
• Support for 1 Gbit/s and 10Gbit/s over fiber using a variety of SFP tagging for business services or open-access networks
modules as well as 2.5 Gbit/s 2500BASE-T using copper-SFPs for example • Customer VLAN topologies with a central Service Router/BNG
to connect wireless access-points • Service VLAN topologies using DHCP snooping for end-user and net-
• Filled with features to deliver voice, video and data services and to sup- work security
port your network team in daily troubleshooting and network operations, • IP strict clients for anti-spoofing
including streaming telemetry • MAC Forced Forwarding prevents layer 2 interaction between clients in
• The MS8000 can be used in a variety of network topologies such as the VLAN, including ARP inspection for increased security
• Customer VLAN topology in combination with a Service Router/BNG • MS8000 can use RADIUS to automatically obtain configuration instructions
with efficient multicast distribution and optional RADIUS based control for ingress shaping of traffic, thereby contributing to network protection
of ingress traffic and improved user experience
• Service VLAN topology where the MS8000 performs service enforce- • Multicast VLAN support and ability to create channel packages allows
ment and isolates end-users securly using MAC Forced Forwarding optimal bandwidth utilization
• TR-101 topologies with VLAN translation • Support of simultaneous forwarding of up to 4.000 multicast groups.
• PPPoE topologies with intermediate agent features for customer • Full VLAN range, up to 4.096 vlans, including double-tagging, and 16.000
identification MAC addresses.
• Mix these features to support transitions from PPPoE to Service VLAN or
Customer VLAN topologies
• Security features such as IP strict clients
• Extendable through the ScriBOS script language to be easily adapted to
fit into a variety of service provisioning solutions
• Industry standard CLI and SNMP support allows easy management and Front to side/rear-side cooling
control of MS8000 operation • Unique airflow solution with front-to-side airflow
• Available with either with 28 SFP+ (MS8024) or 52 SFP+ (MS8048) Ether- • Provide sufficient cooling of the front-panel SFPs even in confined spaces,
net downlink ports close to a rear wall or ETSI 300 mm cabinets
Faster services and advanced traffic classification/ Connectors in the front
forwarding • Connectors are located in the front of the unit for easy access and
• Onboard network processor (NPU) for extensive traffic classification installation
and service oriented bandwidth control and scheduling using advanced • Small form factor, only 24 cm depth
algorithms such as Weighted Fair Queuing (WFQ) • MS7000 fits into narrow spaces in multi-dwelling unit environments, street
• Traffic in both ingress and egress direction handled through the NPU cabinets as well as dense deployment in central office or wiring-closet sites
in order to overcome the traditional limitation of hardware queues and • 12 V DC power input connector is located in the rear to support dual
switch rate-limiting power sources to the unit to allow external power redundancy
• In ASIC-accelerated mode the MS8000 supports policing and shaping on
port queue level
Automated deployment Support for dual stack services
• The MS8000 can be deployed into the network directly out of the box • Supports classification on IPv6 including policies for traffic management
• No need for pre-configuration before installation. and QoS
• Firmware upgrade and complete configuration via standard protocols
Subject to technical changes!
MS8000 3Service Assurance of IPTV-multicast Streaming telemetry
• Inspection of multicast MPEG using the RPM feature to measure the • MS8000 supports streaming telemetry data from over 1,500 data
quality points to provide indepth information about system health and network
• RPM data provides immediate information in case a problem is seen in the performance
network and helps pinpointing the location of the problem in seconds • Data points include optical transmit/receive levels, temperature, fan
• Support of both MPEG over RTP and UDP operation, multicast delay and lost/error packets, packet drop counters,
• Metrics are collected from RTP level, Transport Stream level and packet flow counters, buffer allocation and more
Packetized Elementary Stream level • Telemetry data can be uploaded directly to an InfluxDB or as JSON
• Errors detected include sequence-error per RTP multicast group, jitter objects
per RTP multicast group, missing-sync-byte per TS multicast group and
misaligned per TS multicast group
• Monitoring of both SD-TV and HD-TV streams
Environmental touch
The MS8000 contains less bromide, phoshorous and chlorine compounds In addition, the MS8000 supports Waystreams super low power SFPs that
than comparable products which reduces the health risks associated with can reduce carbon emission and the electricity bill by 20 – 25% on average
electronics. for FTTx equipment.
Your benefits
• FTTH Customer and Service VLAN topology support with advanced QoS
• 28 or 52 SFP+-based downlink ports supporting 1 and 10 Gbit/s speed
• All ports are 10 Gbit/s Ethernet
• Faster services and advanced traffic classification/forwarding
• Front-to-side airflow for optimal cooling
• Telemetry and service assurance of multicast TV
• Automated deployment, right out of the box
• No need for pre-configuration of the switch before installation
• All connectors for network, administration and power are located in the front
of the unit
Subject to technical changes!
4 MS8000ASR8000
10 Gbit/s access switch for FTTH/FTTB
The ASR 8000 is a Layer 3 switch with up to 52 SFP+ ports that support sions and provide layer2 overlay VPN services. Using extended temperature
1/10 Gbit/s speed and advanced service delivery of voice, video and inter- ASR 8000 models you can deploy the switches in outdoor enclosures such as
net in broadband networks. street cabinets.
Using an onboard network processor, the ASR 8000 supports per client Designed for FTTH networks the ASR 8000 has features to make network
bandwidth ingress and egress shaping, weighted fair queuing scheduling, operation easier and enable more automation which lets you reduce opera-
quality measurement of MPEG TV and RADIUS controlled service templates tional cost and save time.
(broadband network gateway functionality). It can even terminate PPPoE ses-
Parameter ASR 8024/8024E ASR 8048/8048E
Port configuration 28 x 1000/10000baseX (SFP+) 52 x 1000/10000baseX (SFP+)
Power supply both AC and DC power models available
Standard iBOS included
Dimensions (H x W x D) [mm] 43 x 441 x 240
Weight [kg] 4
Interface LED indicator for link and speed, dual color
Indicators Power LED indicator
System LED indicator
Redundant fan, sufficient cooling capacity even with one fan failing.
Cooling
Commercial temp: Front-to-side airflow, Extended temp: Front-to-side + back airflow
Operating temperature Commercial temperature: 0 – 45°C, Extended temperature: -20 – 70°C (E-models)
Operating humidity, non-condensing [%] 10 – 90
One IEC 60320-1 C14, located on the front panel (AC-models)
Power Connector Dual -48 V DC connectors, located on the front panel (DC-models)
One 12 V DC connector located on the back panel for external power supply (all models)
Front-panel AC power input 100 – 240 V, 50/60 Hz to internal PSU (AC-models)
Power Front-panel DC power input -48 – 60 V to internal PSU (DC-models)
Rear-panel 12 V DC power input to mainboard (all models)
Power consumption [W] 35 (ASR8024) / 41 (ASR8024E) 85 (ASR8048) / 87 (ASR8048E)
Switch ASIC performance Forwarding bandwidth: 160 Gbps, 240 Mpps
NPU Performance 1.200 Mhz NPU with 4 cores, providing up to 10 Gbps throughput
MAC table 16.000 entries
VLAN table 4.094 entries
Multicast S, G entries 2.048 L2 multicast, 4.000 IP multicast groups
Industry standard CLI with debugging, configuration and management, RS232 serial console to access CLI,
Management
Telnet, SSH, PFDP – PacketFront Device Protocol, SNMP v1, v2c and v3, Syslog, NTP, LLDP
System boot BOOTP client for address assignment
Flow export Netflow version 9
IP spoofing protection, up to 10 Gbps bandwidth IP fragment inspection in NPU,
Subject to technical changes!
Per layer 3-interface packet shaper for packets destined to the control plane,
Security
Restricted multicast access with IGMP join-filter, UNI isolated ports, MAC Forced Forwarding,
DHCPv4 snooping for anti-spoofing, Lawful Interception X1 and X3 interface
Interface mirroring to local interface
Mirroring
Interface mirroring over GRE to remote Wireshark or other packet capture tool
RADIUS RADIUS protocol based service control including Change of Authorization
PPPoE Server PPPoE server operation for 576 users with PAP/CHAP authentication
on request
Order No.
Please contact us to find a solution meeting your demands.
ASR8000 5Product overview Faster services and advanced traffic classification/for-
• Layer 3 access switch/mini-BNG designed for access network service warding
control, network aggregation and traffic classification • 1, 2,5, 5 and 10 Gbit/s port speeds supported to enable faster services
• Filled with features to deliver voice, video and data services • Accelerated traffic in the switch-ASIC provides up to full wire-speed
• Modern technology allowing downlink ports to support 1/2,5/5/10 Gbit/s throughput on all ports as well as rate-limiting
operation • Per client service control via onboard NPU for the best possible user
experience
• Flow-based traffic through the NPU allows highly granular traffic control,
ASR8000 hybrid architecture traffic management and QoS rules
• Hybrid switch-ASIC and NPU architecture
• Full forwarding capacity of a switch-ASIC that delivers L2/L3 switching
with up to wire-speed (128 byte packets) throughput on all ports including Extended temperature range and front to side-back
hardware policing and QoS cooling
• NPU enables unique per client service features with advanced scheduling
• Extended temperature range versions designed to operate even in tough
algorithms such as Weighted Fair Queueing and extended troubleshoo-
conditions
ting tools such as detailed multicast-TV monitoring and analysis
• Unique front-to-side airflow for optimal cooling of all SFP cages
• Network processor supports up to 10 Gbit/s throughput
• Extended temperature models with rear facing fans creating a front-to-
• Can be controlled by the RADIUS protocol
side-back airflow
• Layer 3 routing protocols, also supports layer 2 overlay where layer 2
connectivity can be provides over the routed network
• Supports layer2 switching network topologies such as customer VLAN
topology, service VLAN topology and TR-101 topologies with VLAN trans- Zero touch deployment
lation
• ASR8000 to be deployed into the network directly out of the box without
• Available with either 24 SFP+ (ASR8024) or 48 SFP+ (ASR8048) 10 Gbit/s
pre-configuration
Ethernet downlink ports, additionally there are four 10 Gbit/s SFP+ uplink
• Firmware upgrade and complete configuration via standard protocols
ports
• Reduced need for field engineers to configure units in remote locations
• Available as commerical or extended temperature range versions with AC
or DC power options
Subject to technical changes!
6 TESTConnectors in the front Mini-BNG and PPPoE
• Connectors are located in the front of the unit for easy access and • Same capabilites as Broadband Network Gateways to handle and control
installation services for IP over Ethernet and PPP over Ethernet
• Small form factor, only 24 cm depth • Customized and automated service control can be implemented using the
• ASR8000 fits into narrow spaces in multi-dwelling unit environments, RADIUS protocol
street cabinets as well as dense deployment in central office or wiring- • Existing RADIUS based solutions can be reused to reduce costs in the OSS
closet sites system
• 12 V DC power input connector is located in the rear to support dual • PPPoE or DHCP messages from the client trigger the RADIUS authentica-
power sources to the unit to allow external power redundancy tion process
• Accounting updates provided to the RADIUS-server allow tracking of
traffic volume
Quality improvements and inspection of TV
• Traffic shaping to improve the overall quality of TV distribution, preventing Layer 2 topologies
packet drops in the TV stream
• Inspect multicast MPEG transport streams • The ASR8000 also supports common layer 2 topologies such as Customer-
• Analyze metrics at RTP level, Transport Stream level and Packetized VLAN with separate multicast VLAN and MACFF based Service-VLAN with
Elementary Stream level for up tp 50 SD-TV and HD-TV channels at the secure traffic separation of customer traffic.
same time
• The errors detected include:
• Sequence-errors
• Jitter
• Missing-sync-byte
• Misaligned
• Fast identification of issues affecting sensitive multicast traffic
Your benefits
• 28 or 52 10 Gbit/s SFP+ ports with extended -20 to +70°C temperature models
• Mini-BNG for IPoE/PPPoE networks
• Superior rate-limiting and QoS features
• All connectors in the front and only 24 cm depth
• Efficient distribution of TV including quality measurement
Subject to technical changes!
Subject to technical changes!
TEST 7HIGH DENSITY?
EXTENDED
TEMPERATURE
RANGE?
MS7000!
Subject to technical changes!
8 TESTMS7000
FTTH/FTTB access switch for up to 2,5 Gbit/s downlink speed
The MS7000 Ethernet switch is purpose built for FTTH/FTTB access to The MS7000 series include models that support an extended temperature
enable easy operation and deployment of services. range, allowing deployment in outdoor enclosures such as street cabinets.
It provides you with a feature set to support demanding business and residen- The MS7000 meets network operator needs for long deployment cycles and
tial services such as Internet, TV, wholesale capacity services and private net- reliable network operation and it is purpose built with fiber networks in mind
works at the same time as simplified and automated control of the network lets to support a wide variety of network architectures and service models.
you reduce operational cost and save time when dealing with network issues.
Parameter MS7024/7024E MS7048/7048E
Uplink ports 4 x 1000/10000base-X (SFP+) 4 x 1000/10000base-X (SFP+)
GE ports 24 x 1 G (SFP fiber) / 2,5 G (SFP copper) 48 x 1 G (SFP Fiber) / 2,5 G (SFP copper)
Standard iBOS Standard
Dimensions (H x W x D) [mm] 43 x 441 x 240
Weight [kg] 4
Interface LED indicator for link and speed, dual color
Indicators Power LED indicator
System LED indicator
Redundant fan, sufficient cooling capacity even with one fan failing,
Cooling
Commercial temp: Front-to-side airflow, Extended temp: Front-to-side-back airflow
Operating temperature Commercial temperature: 0 to 45°C, Extended temperature: -20 to 70°C
Operating humidity, non-condensing [%] 10 – 90
One IEC 60320-1 C14, located on the front panel
Power connector
One 12 V DC connector located on the back panel for external power supply
Front-panel AC power input 100 – 240 V, 50/60 Hz to internal PSU
Power
Rear-panel 12 V DC power input to mainboard
Power consumption [W] 35 (MS7024) / 41 (MS7024E) 85 (MS7048) / 87 (MS7048E)
Switch ASIC performance Forwarding bandwidth: 160 Gbps, 240 Mpps
NPU Performance 1.200 Mhz NPU with 4 cores, providing up to 10 Gbps throughput
MAC table 16.000 MAC addresses
VLAN table 4.094 VLANs
Multicast S, G entries 2.048 L2 multicast, 4.000 IP multicast groups
IP spoofing protection, Up to 10 Gbps bandwidth IP fragment inspection in NPU,
Security Restricted multicast access with IGMP join-filter, UNI isolated ports, MAC Forced Forwarding,
DHCPv4 snooping for anti-spoofing
Interface mirroring to local interface,
Mirroring
Interface mirroring over GRE to remote Wireshark or other packet capture tool
Command Line Interface Industry standard CLI with debugging, configuration and management, Telnet, SSH
Serial interface RS232 console serial port to access CLI
SNMP SNMPv1, v2c and v3
Subject to technical changes!
PacketFront Device protocol exchange system information with other iBOS devices
PFDP
Management and selected PFNP c ustomer premise equipment
System boot BOOTP client for address assignment
Time NTP time synchronisation
Remote logging Syslog
LLDP Link Layer Discovery Protocol
on request
Order No.
Please contact us to find a solution meeting your demands.
MS7000 9Product overview Faster services and advanced traffic
• Layer 2 access switch designed for FTTx access networks, network aggre- classification/forwarding
gation and traffic classification and prioritization to deliver the ultimate • Onboard network processor (NPU) gives the extensive traffic classification
user experience and service oriented bandwidth control and scheduling using advanced
• Support for 1 Gbit/s over fiber using a variety of SFP modules as well as algorithms such as Weighted Fair Queuing (WFQ)
2,5 Gbit/s 2500BASE-T using copper-SFPs • Overcome the traditional limitation of hardware queues and switch
• Filled with features to deliver voice, video and data services and to sup- silicone rate-limiting by handling traffic in both ingress and egress
port your network team in daily troubleshooting and network operations direction through the NPU
• The MS7000 can be used in a variety of network topologies such as: • In ASIC-accelerated mode the MS7000 supports policing and shaping on
• Customer VLAN topology in combination with a service router/BNG port queue level
with efficient multicast distribution and optional RADIUS based control
of ingress traffic
• Service VLAN topology where the MS7000 performs service
enforcement and isolates end-users securly
Extended temperature range and front to side/rear-side
• TR-101 topologies with VLAN translation cooling
• PPPoE topologies with intermediate agent features for customer iden-
• Unique airflow solution with front-to-side airflow
tification
• Provide sufficient cooling of the front-panel SFPs even in confined spaces,
• Mix these features to support transitions from PPPoE to service VLAN or
close to a rear wall or ETSI 300 mm cabinets
customer VLAN topologies
• Extended temperature range versions add additional fans blowing to the
• Security features such as IP strict clients
back, creating a front-to-side-back airflow
• Adapt the switches' behavior through the ScriBOS script language
• Operate even in tough conditions with limited external cooling
• Available with either with 24 SFP (MS7024) or 48 SFP (MS7048) Ethernet
downlink ports that operate at 1 or 2,5 Gbit/s link-speed
• Four additional 1/10 Gbit/s SFP+ uplink ports
• Available as commerical or extended temperature range versions with AC Connectors in the front
or DC power options
• Connectors are located in the front of the unit for easy access and
installation
• Small form factor, only 24 cm depth
Automated deployment • MS7000 fits into narrow spaces in multi-dwelling unit environments, street
cabinets as well as dense deployment in central office or wiring-closet sites
• The MS7000 can be deployed into the network directly out of the box
• 12 V DC power input connector is located in the rear to support dual
• No need for pre-configuration before installation
power sources to the unit to allow external power redundancy
• Firmware upgrade and complete configuration via standard protocols
Subject to technical changes!
Subject to technical changes!
10 TESTCustomer and service VLAN topologies Quality inspection of TV
• The MS7000 can be used in a wide variety of network topologies and • Inspect multicast MPEG streams using Realtime Protocol Monitoring (RPM)
supports: • RPM supports MPEG over RTP as well as UDP and collects and analyzes
• Ethernet wholesale with C-VLAN and S-VLAN metrics at RTP level, transport stream level and packetized elementary
• Customer VLAN topologies with a central Service Router/BNG stream level
• Service VLAN topologies using DHCP snooping for end-user and net- • The errors detected include:
work security • Sequence-error per RTP multicast group
• IP strict clients for anti-spoofing • Jitter per RTP multicast group
• MAC Forced Forwarding prevents layer 2 interaction between clients in • Missing-sync-byte per TS multicast group
the VLAN, including ARP inspection for increased security • Misaligned per TS multicast group
• MS7000 uses RADIUS to automatically obtain configuration instructions • Monitoring of both SD-TV and HD-TV streams, up to 50 TV channels at
for ingress shaping of traffic, thereby contributing to network protection the same time
and improved user experience • Ensure continuous monitoring of key channels
• Multicast VLAN support and ability to create channel packages allows
optimal bandwidth utilization
• Support of simultaneous forwarding of up to 4.000 multicast groups Environmental touch
• Full VLAN range, up to 4.096 vlans, including double-tagging, and 16.000
MAC addresses The MS7000 contains less bromide, phoshorous and chlorine compounds
than comparable products which reduces the health risks associated with
electronics.
Support for dual stack services In addition, the MS7000 supports Waystreams super low power SFPs that
can reduce carbon emission and the electricity bill by 20 – 25% on average
• Supports classification on IPv6 including policies for traffic management for FTTx equipment.
and QoS
Your benefits
• FTTH customer and service VLAN topology ready with advanced QoS
• 24 or 48 SFP-based downlink ports with four 10 Gbit/s SFP+ uplinks
• Front-to-side airflow for optimal cooling
• Efficient distribution of TV including quality measurement
• Extended temperature range support -20 to +70°C
Subject to technical changes!
Subject to technical changes!
TEST 1112
Do you have questions concerning our products or want to place an order?
We look forward to your call!
+49 511 757086
Do you already know, which products you need?
shop.brauntelecom.com
13Subject to technical changes!
braun teleCom GmbH Phone +49 511 757086
Merkurstr. 3 c Fax +40 511 753169
30419 Hanover info@brauntelecom.de
Germany www.brauntelecom.com
14 TESTYou can also read