HEART RHYTHM SOCIETY 2021 - SESSIONS OF INTEREST JULY 28-31, 2021 BOSTON EVENTS & CONVENTION CENTER - Abbott cardiovascular
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
HE A R T R H Y THM S O CIE T Y 2021 S E S S I O N S O F IN T ER E S T HEART RHY THM SOCIET Y 2021 SESSIONS OF INTEREST JULY 28-31, 2021 BOSTON EVENTS & CONVENTION CENTER
HE A R T R H Y THM S O CIE T Y 2021 S E S S I O N S O F IN T ER E S T
WEDNESDAY, JULY 28 , 2021
SESSION TIME LOCATION PRESENTATION & AUTHOR
B-PO01 - POSTER SESSION I
B-PO01-042 Exhibit Hall B2 Magnetic Field Mapping of Commonly Used Smart Phones and Their
14:00-14:10 Potential Impact on ICD Therapy
Michael Childers (Abbott, Sylmar CA)
THURSDAY, JULY 29, 2021
SESSION TIME LOCATION PRESENTATION & AUTHOR
B-PO02 - POSTER SESSION II
B-PO02-084 Exhibit Hall B2 Long-Term Effectiveness of Catheter Ablation of Paroxysmal Atrial
10:50-11:00 Fibrillation Using Contact Force Assisted Irrigated Radiofrequency Ablation
Moussa Mansour, MD, FHRS (Massachusetts General Hospital, Boston, MA)
B-PO02-109 Exhibit Hall B2 Safe and Effective Delivery of High-Power, Short-Duration Radiofrequency
10:50-11:00 Ablation Lesions with a Novel, Flexible-Tip Radiofrequency Ablation
Catheter
Leon M Ptaszek, MD, PhD, FHRS (Cardiac Arrhythmia Service, Massachusetts
General Hospitall, Boston MA)
B-AB12 - IMPROVING SAFETY AND EFFICACY OF CATHETER ABLATION
B-AB12-04 Room 210 C Optimal Lesion Size Index to Make Chronic Transmural Continuous Lesion
11:00-11:10 Using Recovery Pig Model
Kennosuke Yamashita, MD, FHRS (Sendai Kosei Hospital, Sendai, Japan)
B-PO03 - POSTER SESSION III
B-PO03-040 Exhibit Hall B2 Helix Fixation Resists Dislodgement yet Facilitates Explantation in Leadless
14:30-14:40 Pacemakers
Petr Neuzil, MD, CSc., FESC (Na Homolce Hospital, Prague, Czech Republic)
B-PO03-082 Exhibit Hall B2 Ablation of Persistent Atrial Fibrillation Using a Novel Contact Force
14:40-14:50 Catheter: Primary Results of the Persist-End Study
Monica Y. Lo, MD, FHRS (Arkansas Heart Hospital, Little Rock, AR)
B-PO03-161 Exhibit Hall B2 Omnipolar Technology Mapping: Derivation and Validation Against Cardiac
16:00-16:10 Magnetic Resonance-Derived Maps and Endomyocardial Biopsy
Paolo Compagnucci, MD (Marche Polytechnic University, Ancona, Italy)HE A R T R H Y THM S O CIE T Y 2021 S E S S I O N S O F IN T ER E S T
FR I DAY, J U LY 30, 2021
SESSION TIME LOCATION PRESENTATION & AUTHOR
B-PO04 - POSTER SESSION IV
B-PO04-072 Exhibit Hall B2 Temperature vs. Power Controlled High Power Short Duration Ablation for
09:50-10:00 Pulmonary Vein Isolation: Procedural Data and Biophysical Characteristics
Marc Kottmaier, MD (German Heart Center, Munich, Germany)
B-PO04-203 Exhibit Hall B2 Cardiovascular Healthcare Utilization in Persistent Atrial Fibrillation
11:40-11:50 Patients Ablated with a Contact Force Catheter
Monica Y. Lo, MD, FHRS (Arkansas Heart Hospital, Little Rock, AR)
B-PO04-132 Exhibit Hall B2 Increased Catheter Stability for Activation Mapping of Papillary Muscle
11:50-12:00 PVCs Utilizing the Abbott HD Grid Mapping Catheter
Parth Makker, BS, MD (Northwell Health - Lenox Hill Hospital & North Shore
University Hospital, New York, NY)
B-PO05 - POSTER SESSION V
B-PO05-206 Exhibit Hall B2 Omnipolar Mapping Clarifies Ambiguous Atrial Tachycardia Isochronal Map
12:50-13:00 in Patient with Tetralogy of Fallot
Jason Jacobson, MD, FHRS (Westchester Medical Center-New York Medical
College, Valhalla, NY)
B-PO05-079 Exhibit Hall B2 Reproducibility of Conduction Velocity Maps Using Omnipolar Traveling
13:40-13:50 Waves and Local Activation Timing
D. Curtis Deno, MD, PhD (Abbott, St. Paul, MN)
B-PO05-042 Exhibit Hall B2 Reducing Clinical Review Burden of Insertable Cardiac Monitors in Patients
15:00-15:10 with Frequent Arrhythmia Detections
John Ip, MD (Sparrow Hospital, Lansing, MI)HE A R T R H Y THM S O CIE T Y 2021 S E S S I O N S O F IN T ER E S T AVA I L A B L E O N L I N E PLEASE VISIT 2021.HEARTRHYTHM.COM AFTER JULY 27 FOR THE FOLLOWING POSTERS Application of Dynamic Mapping Data in Posterior Wall Isolation During Radiofrequency Catheter Ablation of Atrial Fibrillation Hemanth Ramanna, MD, PhD, CEPS-A (Haga Ziekenhuis, Den Haag, Netherlands) Rajesh Venkataraman, MD,FHRS (Houston Methodist The Woodlands, Houston, TX) Chronic Retrievability with a Leadless Pacemaker: A Worldwide NanostimTM Experience Vivek Reddy, MD (Icahn School of Medicine at Mount Sinai, New York, NY) Conduction Velocity Mapping: Validating Time Annotation Agnostic Method From an Optical Mapping Reference Standard Stéphane Massé, MASc, PE (University Health Network, Toronto ON, Canada), Kumaraswamy Nanthakumar, MD (University Health Network, Toronto, ON, Canada) Hi Local Abnormal Ventricular Activity Reveals Conduction Property Different to Systolic Activation Direction Using Omnipolar Methodology: LAVA Flow Karl Magtibay, BEng, MASc (University Health Network, Toronto ON, Canada) Kumaraswamy Nanthakumar, MD (University Health Network, Toronto, ON, Canada) Novel Use of Omnipolar Electrograms to Perform Voltage Mapping in Patients Undergoing Catheter Ablation for Atrial Fibrillation Kathryn L Hong, BSc MSc (University Health Network, Toronto ON, Canada) Benedict M Glover, MD (University Health Network, Toronto ON, Canada) Quantifying the Variability of Bipolar Voltage Amplitude with Sensing Angle in Residual Conduction Isthmuses in Atrial Scar Jose Merino, MD, PhD (La Paz University Hospital, Madrid, Spain) Antonio Carton, MD (La Paz University Hospital, Madrid, Spain) SyncAV and MultiPoint Pacing Improve Left Ventricular Activation as Evaluated by Electrocardiographic Imaging Peter Waddingham, MRCP (Barts Heart Centre, London, UK)
HE A R T R H Y THM S O CIE T Y 2021 S E S S I O N S O F IN T ER E S T CAUTION: This product is intended for use by or under the direction of a physician. Prior to use, reference the Instructions for Use, inside the product carton (when available) or at manuals.sjm.com or eifu.abbottvascular.com for more detailed information on Indications, Contraindications, Warnings, Precautions and Adverse Events. United States: Required Safety Information Abbott One St. Jude Medical Dr., St. Paul, MN 55117 USA, Tel: 1 651 756 2000 Abbott.com ™ Indicates a trademark of the Abbott group of companies. ‡ Indicates a third party trademark, which is property of its respective owner. © 2021 Abbott. All Rights Reserved. MAT-2110040 v1.0 | Item approved for Global use.
You can also read