UNINTERRUPTIBLE POWER SUPPLY (UPS)

UNINTERRUPTIBLE POWER SUPPLY (UPS)

UNINTERRUPTIBLE POWER SUPPLY (UPS)

CATALOGUE 2014 Revision 2.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting Your Data Your Inspirations. Our Innovations.

UNINTERRUPTIBLE POWER SUPPLY (UPS)
UNINTERRUPTIBLE POWER SUPPLY (UPS)

Table of Contents Table of Contents About Us - Company Profile Online UPS Professional Series (1P/1P) - Tower Professional Series (1P/1P) - Dual Master Series (1P/1P) - Tower Master Series (1P/1P) - Combo Master Series (1P/1P) - 2-in-1 Rack/ Tower Master Series (3P/1P) - Tower Master Series (3P/1P) - Rack Mount Master Series (3P/3P) - Tower Power Series PPM Series Line Interactive UPS PRO SFC Series PRO SFT Series PRO Series PRO-L Series PRO Rack/ Tower Series Outdoor Line Interactive Series Inverter UPS LCD Inverter Series Auto Voltage Regulator PVR Series DC UPS PDC Series PBU Series Solar UPS Zonne Series PPS Series PCC Series PSI Hybrid Series PSI On-Grid Amnets Series PSI Off-Grid Haus Series PSI Off-Grid Haus MPPT Series Software & Accessories Appendix 02 04 04 06 08 12 14 18 21 23 25 30 33 33 35 37 39 41 43 45 45 47 47 48 48 49 50 51 52 53 54 55 56 57 59 64 01

UNINTERRUPTIBLE POWER SUPPLY (UPS)

About Us - Company Profile Our Mission Accentuate The Best For The E-generation PROLiNK® aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming more and more commonplace. PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play – our products work harder, while you work smarter to achieve your desired results with less effort and better efficiency.

Providing value to our consumers – whether home or business users, remains a firm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure.

Our Vision Ideas, Innovation and Information PROLiNK® aims to be the key driving force behind technological changes and improvements in both developing and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of innovation, change and improvement so as to provide the next generation of users with products that are suita- ble for their technology advanced environments. The small “i” in PROLiNK represents ideas, innovation and information – three key pillars of growth that drive us towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries.

Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufactured under the brand name “PROLiNK® ” since 1991. With more than two decades of professional experience in the information communications sector, PROLiNK is now renowned as a specialist in its field, especially in the area of Back-up UPS products.

Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efficiently and effectively. The company’s quest for continuous improvement and quality assurance to its customers has earned us the ISO9001 quality certification since 1999.

With its consistently strong commitment to quality, customers can be assured of they are getting true value - superior quality products at affordable prices. 02

UNINTERRUPTIBLE POWER SUPPLY (UPS)

Core Values Secured Information Management With more than two decades of professional experience in providing backup power solutions to our customers, we are able to support our customers with superior technological know-how and expertise, as well as advice on market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage confidential information discreetly. Innovative Design Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With the team’s solid experience in the UPS market, customers can be certain that our designs are innovative yet functional, and suitable for each dynamic market that we have a presence in.

Superior Service Standards Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets our strict standards – from the individual components to the actual finished product. Total Quality Assurance System Our products go through careful planning and checks at every stage of the production cycle - from the beginning stages of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that our customers receive only the best quality goods – of high reliability and durability. Our total quality system has been audited and approved by globally recognized bodies.

Range of UPS The wide range of our products gives you an infinite range of solutions: 1. Online UPS 2. Line Interactive UPS 3. Inverter UPS 4. DC UPS 4. Solar UPS 03 About Us - Company Profile

UNINTERRUPTIBLE POWER SUPPLY (UPS)

Online UPS Professional Series (1P/1P) - Tower Online Professional Series 1kVA – 6kVA Professional Series (1P/1P) is an advanced yet affordable single-phase UPS system that uses on-line double conversion technology. It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments. This device is able to provide high-efficiency charging with its high input power factor correction.

Professional Series is available in capacities ranging from 1000VA to 6000VA. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. Users can also have the option to top-up an additional isolation transformer to obtain pure and clean power for their sensitive devices.

• True Double-Conversion Online UPS • Wide input voltage range (110~300VAC) • Input Power Factor correction of 0.98 • Output Power Factor of 0.80 • Generator compatible • LCD User Interface • Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface • Smart battery charger designed to optimize battery performance • Isolation transformer (optional) Work-Stations Servers Local Area Network (LAN) Small Computer Network Rear Panel For 1kVA to 6kVA model 1. Output receptacles 2. AC input 3. Input circuit breaker 4. Network/Fax Modem Surge Protection 5. Intelligent slot for communication port/ SNMP.

(standard come with USB port) 6. External battery connection (only available for L model) 7. Output terminal 8. Output circuit breaker 9. Fan 5 6 9 4 3 2 1 5 9 3 2 7 1 8 4 6 PRO901S/L PRO902S/L PRO903S/L 5 9 1 8 4 6 2 7 PRO906S/L 04

UNINTERRUPTIBLE POWER SUPPLY (UPS)

Online UPS Full Specifications • RS-232 Port (communication interface). • AS-400 Card (External alarm indicator). • SNMP Card for data communication via network connection. • Output Isolation Transformer. • External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3kVA only) Options 50 or 60Hz 110-300 VAC ± 5 % at 50% / 160-300 VAC ± 5 % at 100% 200/208/220/230/240 VAC Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor 40 ~ 70Hz ≧ 0.98 6000 VA Capacity 1000 VA 2000 VA 3000 VA Valve regulated Lead Acid battery (Maintenance free batteries) Type Capacity Liner Load Non-Liner Load Recharge Time (Typical) Charging Current Standard Model Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions Safety: EN62040-1-1; EMI62040-2; EN62040-3 Regulations INPUT MODELS PRO906S/ L PRO901S/ L PRO902S/ L PRO903S/ L OUTPUT BATTERY MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD INDICATORS EFFICIENCY Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC USB 1.5 seconds >130% 100% < Load < 110% LCD Display AC Mode ±1% ±3% 0.8 Static Regulation Frequency Range Frequency Power Factor Current Crest Ratio Voltage Distortion ≦ 3 % THD ≦ 7 % THD Waveform 1.0 A (max) 47 ~ 53 Hz or 57 ~ 63 Hz 50Hz or 60Hz auto selection Pure Sinewave 9AH 9 hours recover to 90% capacity Up to 88% 3:1 10AH Type Long-Run Model Capacity Charging Current 1A / 2A / 4A / 8A (Default) 1A / 2A / 4A / 6A (Default) Overload warning only (No shutdown) 110% < Load

UNINTERRUPTIBLE POWER SUPPLY (UPS)

06 Professional Series (1P/1P) - Dual Online Professional Series 1kVA – 3kVA • Online True double-conversion • Accepts Ultra Low Voltage inputs for special power environment • Wide input voltage range (88-144VAC and 176-288VAC) at full load • Input Power factor correction of 0.99 • Output Power Factor of 0.80 • LCD User Interface • Complete galvanic isolation design offers full isolation and complete common mode noise rejection • Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface Professional Series (1P/1P) - Dual is an advanced yet affordable single-phase UPS system that uses on-line double conversion technology with 2 different input voltage ranges.

It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments. Professional Series (1P/1P) – Dual is most suitable to be used in areas that are plagued by voltages that are as low as 100V. With the advanced double-conversion technology, the dual series is able to regulate and maintain consistent output even when it is fully loaded. Also, this device is able to provide full isolation and complete common mode noise rejection from complementary equipment. The Dual Series is available in various capacities, ranging from 1000VA to 3000VA.

Online UPS Rear Panel PRO902D S/L PRO903D S/L Work-Stations Servers Local Area Network (LAN) Small Computer Network For 1kVA to 3kVA model 1. Output receptacles 2. AC input 3. Input circuit breaker 4. Network/Fax/Modem surge protection 5. Intelligent slot for communication port/SNMP (standard come with USB port) 6. External battery terminal (only available for Long-run model) 7. Output terminal 8. Output circuit breaker 9. Fan PRO901D S/L 5 9 9 6 1 2 3 4 5 9 9 6 1 2 9 4 5 9 9 9 8 6 1 2 7 4

UNINTERRUPTIBLE POWER SUPPLY (UPS)

07 Online UPS Full Specifications 50 or 60Hz 88VAC ~ 144VAC and 176VAC ~ 288VAC (auto sensing) 208/ 220/ 230/ 240VAC Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor 45 ~ 65Hz ≧ 0.99 Capacity 1000 VA 3000 VA Valve regulated Lead Acid battery (Maintenance free batteries) Type Capacity Recharge Time (Typical) Charging Current Standard Model Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations INPUT MODELS PRO901D S/L 2000 VA PRO902D S/L PRO903D S/L OUTPUT BATTERY MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD INDICATORS EFFICIENCY Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC USB/ RS-232 1.5 seconds >130% 100% < Load < 110% LCD Display AC Mode ±1% 0.8 Static Regulation Frequency Range Frequency Power Factor Current Crest Ratio Voltage Distortion Linear Load Non-Linear Load ≦ 6% THD ≦ 2% THD Waveform 1.0 A (max) 47 ~ 53 Hz or 57 ~ 63 Hz 50Hz or 60Hz auto selection or selectable Pure Sinewave 9AH 5 hours recover to 90% capacity Up to 80% 3:1 Type Long-Run Model Capacity Charging Current Overload warning only (No shutdown) 110% < Load < 130% 30 seconds Depending on the application 4.0 A or 8.0 A (max.) Depending on the application 208/ 220/ 230/ 240VAC Output Voltage 423 x 145 x 332 426 x 190 x 448 421 x 190 x 448

08 Online UPS Master Series (1P/1P) - Tower Online Master Series 1kVA – 10kVA Master Series (1P/1P) is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and high quality electrical power for devices such as small computer centres, servers, telecom applications, lab testing equipments and industrial applications. The Master series (1P/1P) comes with a wide input voltage range that protects devices against outages, disturbances and spikes. In addition, this device comes with a smart battery charger that optimizes the battery performance, ensuring longer lasting battery life.

High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The Master series (1P/1P) also comes in various capacities ranging from 1kVA to 10kVA to suit your needs. The 6kVA and 10kVA UPS system comes with 2 additional features; an internal bypass system and a parallel redundant system. An internal bypass system allowing continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other. • True Double-Conversion Online UPS • Wide input voltage range (110~300VAC) • Input Power Factor correction of 0.99 • Output Power Factor 0.80 • Generator compatible • LCD User Interface • Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface • Smart battery charger designed to optimize battery performance Work-Stations Servers Local Area Network (LAN) Small Computer Network Rear Panel For 1kVA to 3kVA model 1.

Programmable outlets: connect to non-critical loads 2. Output receptacles: connect to mission critical loads 3. AC input 4. Input circuit breaker 5. Network/ Fax/ Modem surge protection 6. Emergency power off function connector (EPO) 7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot 10. External battery connection (only available for L model) 11. Output terminal 12. Output circuit breaker 13. Fan PRO802S/L PRO803S/L PRO801S/L PRO8015S/L 9 5 6 8 7 13 10 4 3 2 1 9 5 2 1 7 8 6 4 3 10 13 13 9 5 2 1 7 8 6 3 4 10 12 11 13 13

09 Online UPS For 6kVA to 10kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance bypass switch 10. Input circuit breaker 11. Input/Output terminal 12. Output terminal 1 13. Output terminal 2 14. External battery terminal (only available for Long-run model) 15. Utility input terminal 16. Output IEC Socket 9 5 5 2 1 7 8 8 6 4 3 15 12 13 14 16 11 10 PRO806S/L PRO810S/L Battery Pack For 1kVA to 3kVA model For 6kVA to 10kVA model Model Battery Type Battery Number (max) Dimension (DxWxH) mm Weight (kg) G6 6 pcs 18 6 pcs 397 × 145 × 220 20 12 pcs 36 G18 G12 12 pcs 18 pcs 18 pcs 421 × 190 × 318 40 55 12V9AH 12V7AH 12V7AH 12V9AH 12V7AH 12V9AH 535 × 190 × 318 61 Model Battery Type Battery Number (max) Dimension (DxWxH) mm Weight (kg) 40 pcs 109 G40 G60 40 pcs 60 pcs 60 pcs 592 × 250 × 576 125 166 12V7AH 12V9AH 12V7AH / 12V90AH 830 × 250 × 576 190

10 Online UPS Full Specifications Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection. • Output Isolation Transformer. • External PDU & Maintenance Bypass Switch. (Only suitable for UPS that are up to 3kVA) A derate will occur during the Frequency converter mode (Capacity is reduced to 60%) and when the output voltage is adjusted to 208VAC (Capacity is reduced to 80%). If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run model S stands for Standard model I stands for Isolation Transformer (Optional) *All specifications, designs and contents are subject to change without prior notice.

50 or 60Hz 110 - 300 VAC ± 5 % at 50% load / 160 - 300 VAC ± 5 % at 100% load 200/208/220/230/240 VAC Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor 40 ~ 70Hz ≧ 0.99 3000 VA Capacity 1000 VA 1500 VA 2000 VA Valve regulated Lead Acid battery (Maintenance free batteries) Type Capacity Recharge Time (Typical) Charging Current Standard Model Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations INPUT MODELS PRO803S/ L 6000 VA PRO806S/ L 10000 VA PRO810S/ L PRO801S/ L PRO8015S/ L PRO802S/ L OUTPUT BATTERY MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD INDICATORS EFFICIENCY Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8, Linux, Unix, and MAC USB/ RS-232 2 seconds >130% 100% < Load < 110% LCD Display AC Mode ±1% 0.8 Static Regulation Frequency Range Frequency Power Factor Current Crest Ratio Voltage Distortion Linear Load Non-Linear Load ≦ 2% THD ≦ 3% THD ≦ 4% THD ≦ 6% THD Waveform 1.0 A (max) 47 ~ 53Hz or 57 ~ 63Hz 50Hz or 60Hz auto selection or selectable Pure Sinewave 9AH 9AH 7AH 7AH 7AH 9 hours recover to 90% capacity Up to 90% 3:1 9AH Type Long-Run Model Capacity Charging Current 8.0 A (max) 4.0 A (max) Overload warning only (No shutdown) 110% < Load < 130% 30 seconds Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage 397×145×220 26 28 13 421 × 190 × 318 421×190×318 81 13 592 x 250 x 576 592 x 250 x 576 83 25 27

11 Online UPS Programmable Outlets (P1) - connect to non-critical devices True double-conversion Online UPS A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications. Higher Accuracy for Output Voltage The advanced control firmware allows the Master Series (1P/1P) to achieve higher accuracy with the output voltage tolerance of +/- 1%. The device is applicable for the use with critical test and IT equipments. Smart Battery Charger Design to Optimise Battery Performance Master Series (1P/1P) 1-3kVA models are equipped with a 2-stage charger design to guarantee precise battery discharge time.

The charging voltage is also automatically adjusted according to the ambient temperature, to lengthen the service life of the battery. The 6kVA and 10kVA models come with an additional extendable charger that allows for large-capacity battery charging.

DSP Technology (Applies for the above models) A DSP controller improves the performance and efficiency of the UPS. Maintenance Bypass Available For 6kVA And Above Models Internal bypass assures continuous power to critical devices during UPS maintenance. Optional Hot Standby and N+X Parallel Redundant System (Available for Models ranging from 6kVA and above) An internal bypass system allowing continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other.

Output Power factor of 0.8 As compared to the online UPS models in the current market, the Master Series (1P/1P) provides better output power factor of up to 0.8.

This unit is able to offer higher performance and efficiency for your critical applications. Wide Input Voltage Range (110 V -300 V) Master Series (1P/1P) can still provide stable power to connected devices under unstable power environments. 50/60 Hz Frequency Converter Mode Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.

ECO Mode Operation For Energy Saving Offers efficiency as high as 97% to cut energy usage & cost. UPS power application via static bypass, timely returning to online double conversion when the need arises. Emergency Power Off (EPO) Function This feature can protect the personnel and the equipment in the case of fire outbreak or other types of emergency. SNMP + USB + RS-232 Multiple Communication port for Models ranging from 1 to 3kVA. This feature allows either the USB or RS-232 communication port to simultaneously operate with the SNMP interface.

Programmable Power Management Outlets The programmable power management outlets allow users to easily and independently control the load segment.

In the event of a power failure, this feature enables users to manage and extend the battery time for mission critical devices by shutting down the non-critical devices.

12 Online UPS Master Series (1P/1P) - Combo Online Master Series 6kVA – 10kVA • True double-conversion on line UPS • DSP technology guarantees high performance • Wide input voltage range (110-300 VAC) • Active input power factor correction of 0.99 • Output power factor of 0.8 • 50Hz/60Hz frequency converter mode • Standard backup UPS and long backup UPS in one integrated unit • Charging current can be adjusted via LCD or software (1A~6A) • Emergency power off function (EPO) • Comes with a USB and PS-232 communication port • Comes with a mini slot for AS-400 / SNMP communication card • Comes with a maintenance bypass function Work-Stations Servers Local Area Network (LAN) Small Computer Network Rear Panel For 6kVA to 10kVA model 1.

RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Intelligent slot 5. Power stage fan 6. Maintenance bypass switch 7. Input circuit breaker 8. Input/Output terminal 9. External battery terminal (only available for Long-run model) 10. Battery Compartment (only available for Standard model) Master Series (1P/1P) - Combo is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and high quality electrical power for devices such as small computer centres, servers, telecom applications and industrial applications.

Designed with a small footprint, this device ensures that it will fit into any corner of your small office. Master Series (1P/1P) - Combo series comes with a wide input voltage range that protects devices against the outages, disturbances and spikes. Fitted with a smart battery charger design, this device is able to optimize its battery performance, ensuring longer lasting battery life. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The Combo series are available in the following capacities; 6kVA and 10kVA. PRO806C/ PRO810C PRO806CL/ PRO810CL 9 5 6 8 7 4 3 2 1 5 6 8 7 4 3 2 1 10

13 Online UPS Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection. • Output Isolation Transformer. 50 or 60Hz 110-300 VAC at 50% load / 176-300 VAC at 100% load 208/ 220/ 230/ 240VAC Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor 46 ~ 64Hz ≧ 0.99 Capacity 6000 VA 10000 VA Valve regulated Lead Acid battery (Maintenance free batteries) Type Capacity Recharge Time (Typical) Charging Current Standard Model Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations INPUT MODELS PRO806C/ CL PRO810C/ CL OUTPUT BATTERY MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD INDICATORS EFFICIENCY Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC USB/ RS-232 1 second >130% 100% < Load < 110% LCD Display AC Mode ±1% 0.8 Static Regulation Frequency Range Frequency Power Factor Current Crest Ratio Voltage Distortion Linear Load Non-Linear Load ≦ 6% THD ≦3 % THD Waveform 2.0A 46 ~ 54Hz or 56 ~ 64Hz 50Hz or 60Hz auto selection or selectable Pure Sinewave 9AH 7AH 9 hours recover to 90% capacity Up to 90% 3:1 Type Long-Run Model Capacity Charging Current 6.0 A (max) 10 minutes 110% < Load < 130% 1 minute Depending on the application Depending on the application 208/ 220/ 230/ 240VAC Output Voltage 360 x 192 x 318 440 x 192 x 688 440 x 192 x 318

14 Online UPS Master Series (1P/1P) - 2-in-1 Rack/ Tower Online Master Series 1kVA – 10kVA Master Series (1P/1P) – 2-in-1 Rack/Tower is a single-phase UPS system that employs a true online double-conversion technology. This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounted position using a 19-inch rack mount bracket. With its high density output power factor of 0.9, this device is able to provide outstanding performance and efficiency to meet the requirements of a mission critical environment.

This 2-in-1 Rank/Tower UPS is brilliantly designed with a hot-swapping battery feature to facilitate the replacement of the existing batteries without the hassle of having to shut the devices down. On top of that, models with a 6kVA and 10kVA capacity comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The PROLiNK 2-in-1 Rank/Tower UPS comes with a wide range of capacities from as low as 1kVA to as high as 10kVA to accommodate to your every need.

• True Double-Conversion Online UPS • Rack or Tower design • Wide input voltage range (110~300VAC) • Input Power Factor correction of 0.99 • Output Power factor of 0.90 • 50/60Hz frequency converter mode • Hot-Swappable battery design • Emergency Power Off (EPO) function • ECO Operation Mode provides energy conservation • Generator Compatible • Option available for long-run models to expand the charger capacity to 8A • Multiple communication interface (SNMP/USB/RS-232) • Smart battery charger is designed to optimize overall battery performance • Selectable output voltage via LCD panel Work-Stations Servers 19” Rack Mount Local Area Network (LAN) Small Computer Network

15 Online UPS Rear Panel For 1kVA to 3kVA model 1. Programmable outlets: Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3. AC input 4. Input circuit breaker 5. Network/Fax/Modem surge protection 6. Emergency power off function connector (EPO) 7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot 10. External battery terminal (only available for Long-run model) 11. Output IEC320-C20 connector 12. Fan For 6kVA to 10kVA model 1. Programmable outlets: Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3.

AC input 4. Input circuit breaker 5. Network/Fax/Modem surge protection 6. Emergency power off function connector (EPO) 7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot 10. Battery connection 11. Input terminal 12. Fan 13. Parallel port (only available for parallel model) 14. External maintenance by-pass switch connection 15. Output Terminal 16. Ground PRO806RS/RL PRO810RS/RL 6 9 4 7 7 12 10 14 13 11 16 15 Battery Pack For 1kVA to 10kVA model Model Battery Type Battery Number (max) Dimension (DxWxH) mm Weight (kg) G8R 8 pcs 480 × 438 × 88 29.8 G12R G20R 12 pcs 20 pcs 42.5 57 12V9AH 12V7AH 12V9AH 580 × 438 × 133 600 × 438 × 88 63 PRO803RS/RL 5 12 12 10 6 7 8 9 1 2 3 11 4 PRO801RS/RL PRO8015RS/RL PRO802RS/RL 5 12 10 6 7 8 9 1 2 3 4

16 Online UPS • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection • MODBUS Card (communication interface) • Universal Rackmount Slider for installation in rack cabinets • External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA) • Maintenance Bypass Switch [MBS] (Only available in UPS ranging from 6 to 10kVA) • External Automatic Transfer Switch (ATS) Options Full Specifications 50 or 60Hz 110-300 VAC at 50% load / 160-300 VAC at 100% load 200/ 208/ 220/ 230/ 240 VAC Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor 40 ~ 70Hz ≧ 0.99 3000 VA Capacity 1000 VA 1500 VA 2000 VA Valve regulated Lead Acid battery (Maintenance free batteries) Type Capacity Recharge Time (Typical) Charging Current Standard Model Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations INPUT MODELS PRO803RS/ RL 6000 VA PRO806RS/ RL 10000 VA PRO810RS/ RL PRO801RS/ RL PRO8015RS/ RL PRO802RS/ RL OUTPUT BATTERY MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD INDICATORS EFFICIENCY Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC USB/ RS-232 2 seconds 1 second >130% 100% < Load < 110% LCD Display AC Mode ±1% 0.9 Static Regulation Frequency Range Frequency Power Factor Current Crest Ratio Voltage Distortion Linear Load Non-Linear Load ≦ 4 % THD ≦ 2% THD Waveform 1.0 A (max) 47 ~ 53Hz or 57 ~ 63Hz 50Hz or 60Hz auto selection or selectable Pure Sinewave 9AH 4 hours recover to 90% capacity 9 hours recover to 90% capacity Up to 90% 5:1 5:1 3:1 7AH 9AH Type Long-Run Model Capacity Charging Current 1A / 2A / 4A / 8A 4.0 A (max) Overload warning only (No shutdown) 10 minutes 110% < Load < 130% 30 seconds 1 minute Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage 380x438x88 (2U) 480x438x88 (2U) 20.6 28 11.3 480x438x88 (2U) 600x43x88(2U) UPS unit: 20 Battery pack: 57 UPS unit: 23.5 Battery pack: 63 13.8 Battery Unit: 580x438x133 (3U) UPS Unit: 580x438x133 (3U) Battery Unit: 580x438x133 (3U) UPS Unit: 688x438x133 (3U) 600x438x88 (2U) 580x438x133 (3U) 668x438x133 (3U) 20 23.5 < 95 % non-condensing 0°C - +40°C Operation Humidity Ambient Temperature < 60dBA @ 1 Mete Noise Level 380x438x88 (2U) 12.9 17.6 8.6 10.7 Dimension (mm) D x W × H Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model Long-Run Model L stands for Long-run model S stands for Standard model *All specifications, designs and contents are subject to change without prior notice.

17 Online UPS Programmable Outlets (P1) - connect to non-critical devices True Double-conversion Online UPS A true double conversion UPS system will provide clean and high quality electrical power to fully protect mission critical systems such as sensitive networks, small computer centers, servers, telecom applications and industrial applications. Programmable Power Management Outlets The programmable power management outlets allow users to easily and independently control the load segment. In the event of a power failure, this feature enables users to manage and extend the battery time for mission critical devices by shutting down the non-critical devices.

ECO and Advanced ECO Mode for Energy Saving It allows the UPS to operate in high efficiency of up to 97% during energy saving ECO mode and 98% in operation mode. In the event of an electrical AC failure, the inverter will automatically step-in and provide electrical supply to the connected systems. Emergency Power Off Function (EPO) This feature provides adequate protection for the user and the equipment against hazards such as fire break-out or other emergencies. Hot-swapping Battery Design The hot-swapping battery feature helps to facilitate the replacement of the existing batteries without the hassle of having to shut the devices down.

Long Battery Runtime Models Available Our Long Battery Runtime Models offers the flexibility to add-on additional external batteries to provide a longer back-up time. User-friendly LCD Display The front panel digital display comes with an auto- rotation feature that caters to your installation preference; either vertically or wall mounted. Rack / Tower Design This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounting position using a 19-inch rack mount bracket.

High Output Crest Ratio The Master (1P/1P) 2-in-1 Rack/Tower Series is designed with a high output crest ratio of 5:1 that allows the device to be extremely compatible with equipment such as compressors, generators and motors.

Output Voltage Regulation (tolerance +/- 1%) The Master (1P/1P) 2-in-1 rack / Tower Series is able to produce extremely stable and clean electrical power with its high efficiency output voltage regulator. This regulator is able to achieve a tolerance of +/- 1%, making it extremely compatible even with sensitive power supplies.

Output power factor 0.9 Master (1P/1P) 2-in-1 rack/Tower Series is a high-density UPS system with an output power factor of 0.9. With this high power factor, the Master series is able to provide higher performance to critical applications. Rack Display Tower Display 19” Rack-mounting Floor-standing Tower

18 Online UPS Master Series (3P/1P) - Tower Online Master Series 10kVA – 30kVA • True Double-Conversion Online UPS • DSP technology guarantees high performance • Input Power Factor Correction 0.99 • Active power factor correction in all phases • 50/60Hz frequency converter mode • Multiple communication interface (SNMP/USB/RS-232) • Wide input voltage range • Output Power Factor 0.80 • Comes with a maintenance bypass function • Optional N+X parallel redundancy • Emergency Power Off (EPO) function • Isolation transformer (Optional) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Local Area Network (LAN) Telecommunication Devices PRO83110S/L Rear Panel For 10kVA model 1.

RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance by-pass switch 10. Input circuit breaker 11. Output circuit breaker for receptacles 12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal 14. External battery connector (Only available for Long-run Model) 5 5 13 14 12 10 7 8 8 9 6 1 2 3 4 11 Master Series (3P/1P) three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers, telecommunication systems and industrial equipment.

The (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.

This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) UPS also offers the option of adding on an isolation transformer to suit your requirements.

19 Online UPS PRO83115L PRO83120L PRO83115S PRO83120S PRO83130S/L PRO83130L For 15kVA to 30kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance by-pass switch 10. Input circuit breaker 11. Output circuit breaker for receptacles 12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal 14. Output Terminal: Connect to mission-critical loads 15.

Programmable Output terminal: Connect to non-critical loads 16. External battery terminal (only available for Long-run model) 17. Utility input terminal 18. Grounding terminal (only available for parallel system) 5 5 11 18 10 7 7 8 8 9 6 1 2 3 4 5 5 11 10 7 7 8 8 9 6 1 2 3 4 For 15K & 30K model For 10K model 14 15 17 15 16 17 14 18 • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer Options

20 Online UPS 50 or 60Hz 305-478 VAC (3-phase) at 100% load 3 x 400 VAC (3Ph+N) Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor 46 ~ 64Hz ≧ 0.99 Capacity 10 kVA 15 kVA 20 kVA Valve regulated Lead Acid battery (Maintenance free batteries) Type Capacity Liner Load Non-Liner Load Recharge Time (Typical) Charging Current Standard Model Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations INPUT MODELS PRO83110S/ L PRO83115S/ L PRO83120S/ L 30kVA PRO83130 (S/L) OUTPUT BATTERY MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD INDICATORS EFFICIENCY Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8, Linux, Unix, and MAC USB 1 second >130% 100% < Load < 110% LCD Display AC Mode ±1% 0.8 Static Regulation Frequency Range Frequency Power Factor Current Crest Ratio Voltage Distortion ≦ 2% THD ≦ 5% THD Waveform 1.0 A (max) 2.0 A (max) 4.0 A (max) 8A 4A 12.0 A (max) 50 ~ 60Hz ± 0.1 Hz 50Hz or 60Hz auto selection or selectable Pure Sinewave 9AH 9 hours recover to 90% capacity Up to 90% 3:1 Type Long-Run Model Capacity Charging Current 10 minutes 110% < Load < 130% 1 minute Depending on the application Depending on the application 208/ 220/ 230/ 240VAC Output Voltage 592 ×250 × 576 164 40 815 × 250 × 826 592 x 250 x 576 234 64 815 × 300 × 1000 815 × 250 × 826 IP20

21 Master Series (3P/1P) - Rack Mount Online Master Series 10kVA – 20kVA • True double-conversion • DSP technology guarantees high performance • Output Power Factor 0.8 • Wide input voltage range • Active power factor correction in all phases • 50Hz/60Hz frequency converter mode • Eco mode operation for energy saving (ECO) • Emergency power off function (EPO) • Generator compatible • Multiple communication interface (SNMP/USB/RS-232) • Adjustable battery numbers • Optional N+X parallel redundancy Master Series (3P/1P) – Rack three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers, telecommunication systems and industrial equipments.

This (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.

This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 20kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) – Rack UPS also offers the option of adding on an isolation transformer to suit your requirements.

Online UPS Data Centre 19” Rack Mount Storage PLCS Emergency Alarm Devices Local Area Network (LAN) Telecommunication Devices 5 12 10 7 8 9 6 6 1 2 3 4 4 4 11 5 12 10 7 8 9 6 6 6 6 1 2 3 4 4 4 11 Rear Panel For 10kVA to 20kVA model 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Parallel port (only available for parallel model) 5. Intelligent slot 6. Fan 7. External maintenance by-pass switch connection 8. Input circuit breaker 9. Input/Output terminal 10. Output terminal 11. Battery terminal 12. Input terminal PRO83110RS/RL PRO83120RS/RL

22 Online UPS • AS-400 Card (External Alarm Indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Universal Rackmount Slider for installation in rack cabinets • External Maintenance Bypass Switch (Only available with 10kVA model) Options Full Specifications 50 or 60Hz 305-478 VAC (3-phase) at 100% load 3 x 400 VAC (3Ph+N) Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor 46 ~ 64Hz ≧ 0.99 Capacity 10kVA 20kVA Valve regulated Lead Acid battery (Maintenance free batteries) Type Capacity Recharge Time (Typical) Charging Current Standard Model Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations INPUT MODELS PRO83110RS/ RL PRO83120RS/ RL OUTPUT BATTERY MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD INDICATORS EFFICIENCY Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC USB/ RS-232 1 second >130% 100% < Load < 110% LCD Display AC Mode ±1% 0.8 Static Regulation Frequency Range Frequency Power Factor Current Crest Ratio Voltage Distortion Linear Load Non-Linear Load ≦ 5% THD ≦ 2% THD Waveform 1.0 A (max) 2.0A (max) 46 ~ 54Hz or 56 ~ 64Hz 50Hz or 60Hz auto selection or selectable Pure Sinewave 9AH 9 hours recover to 90% capacity Up to 89% 3:1 Type Long-Run Model Capacity Charging Current 10 minutes 110% < Load < 130% 1 minute Depending on the application 4.0 A (max) Depending on the application 208/ 220/ 230/ 240VAC Output Voltage 668 x 438 x 133 (3U) UPS Unit: 668 x 438 x 266 (6U) BatteryPack: 580 x 438 x 133 (3U) x 2 668 x 438 x 266 (6U)

23 Online UPS Master Series (3P/3P) - Tower Online Master Series 10kVA – 30kVA • True Double-Conversion Online UPS • DSP technology guarantees high performance • Input Power Factor Correction 0.99 • Active power factor correction in all phases • 50/60Hz frequency converter mode • Multiple communication interface (SNMP/USB/RS-232) • Wide input voltage range • Output Power Factor of 0.80 • Comes with a maintenance bypass feature • Optional N+X parallel redundancy • Emergency Power Off (EPO) function • Isolation transformer (Optional) Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Local Area Network (LAN) Telecommunication Devices Master Series (3P/3P) – Tower three-phase input / three-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as small server room, medical devices, telecommunication facilities and industrial processes.

This (3P/3P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.

The Master Series (3P/3P) UPS system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage-switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Tower series UPS also offers the option of adding on an isolation transformer to suit your requirements.

Rear Panel For 10kVA to 30kVA model 1.

RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 7. Charger fan 8. Power stage fan 9. Maintenance bypass switch 10. Bypass Input Circuit Breaker (Only available for dual input unit) 11. Input circuit breaker 12. Input/Output terminal 13. External battery terminal (only available for Long-run model) 12 10 13 7 7 6 8 8 9 1 2 3 4 11 5 PRO83310S/L PRO83320S/L PRO83330S/L

24 Online UPS • AS-400 Card (External Alarm Indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer Options Full Specifications 50 or 60Hz 300VAC

25 Online UPS Power Series Online Power Series 15kVA – 120kVA • Online double conversion technology with DSP control • Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology • Very low input current distortion (THDi < 1%) • Input power factor 0.99 at 10% load • Output efficiency up to 95% • Control designed to withstand all kinds of loads • Variety of communication options available • Optional N+X parallel redundancy • Remaining backup time calculation • Optional isolation transformer Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Local Area Network (LAN) Telecommunication Devices Power Series (3P/3P) three-phase input / three-phase output, true online double conversion UPS system guarantees to supply consistent and quality electrical power to protect your mission critical applications such as data centres, medical equipments and call centres.

Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonic distortion and high input power factor, it is able to lower installation costs by utilizing smaller cablesandminiaturecircuitbreakers(MCB).

OurteamofspecialistshasgatheredtogethertorevolutionizetheUPSusabilitybyaddi ngina 5.7” LCD monitor display with all information and alarm notifications viewable within a single display. To ensure our products are user centered, our group of specialist has also adopted a front access concept to create a UPS system that is easy for users to carry out preventative maintenance and replacement activities. In addition, this device comes with a parallel redundant system that allows four UPS models to operate in parallel. An option of an additionalisolationtransformerisalsoavailabletosuityourrequirements.ThePowe rseriesis availableinmodelsrangingfrom15kVAto120kVA.

Rear Panel (Internal) For 15kVA to 80kVA model 1. Relay interface 2. Emergency Power Off (EPO) 3. RS-232 COM ports 4. Intelligent Slow 5. Input circuit breaker 6. Maintenance bypass switch 7. Output switch 8. Battery switch 9. System Terminal 10. Parallel port (only available for parallel model) 5 10 7 6 9 1 2 3 8 4 PRO73315S/SI PRO73320S/SI PRO73330S/SI PRO73340S/SI 5 10 7 6 9 1 2 3 8 4 PRO73360S/SI PRO73380S/SI 5 10 7 6 9 1 2 3 8 4

PRO733100S PRO733120S Full Specifications 50 or 60Hz 300VAC

Online UPS • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer Options 50 or 60Hz 300VAC

Online UPS The Most Versatile Solution For Power Protection The Power Series is designed with the new state of art transformerless PWM technology that can be easily adapted to any kinds of complicated loads such as the non-linear systems (IT systems), highly inductive/ capacitive loads, high-density discharge lamps and induction motors. The Power series is designed with 2 important criterions in mind; maximum efficiency and energy conservation. The unit also comes with a small form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to allow two UPS models to operate in parallel as backup for each other.

The Power Series is available in capacities ranging from 15 to 120kVA. Online Double Conversion Technology with DSP Control The Power Series is able provide a higher load up-time and effective insulation against network disturbance with its online double conversion technology. A Digital Signal Processor (DSP) controller improves the performance and efficiency of the UPS. Advanced Control with Adaptive Feed Forward Cancellation (AFC) Technology By cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic injection can be eliminated and this enhances the load integrity.

Low Input Current Distortion (THDi < 1%) AFC cells are used to achieve extremely low distortion values. The Power series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network. Input Power Factor 0.99 At 10% Load Lower power losses would result in reduced consumption, lower operation and maintenance costs. Output Efficiency of up to 95% Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely high efficiency of up to 95%.

With such high ratings, components in the UPS are not only protected but also prolonged due to the decrease in heat losses. Small Form Factor Utilizes a transformerless technology allows the design of the UPS to be lighter and smaller.

1,20 1,00 0,80 0,60 0,40 0,20 0,00 0% 25% 50% LOAD INPUT POWER FACTOR PFin 100% 75% 50% 25% 0% 0% SERIES TIPICAL EFFICIENCY 25% 50% EFFICIENCY LOAD 28