UCB BIOSCIENCES 4000 Paramount Pkwy Suite 200 & 300 Morrisville, NC 27560 - Mechworks Mechanical Contractors
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
UCB BIOSCIENCES
4000 Paramount Pkwy
Suite 200 & 300
Morrisville, NC 27560
Gensler
Architect
613 Hillsborough Street
Raleigh, NC, 27603
Telephone 919.239.7828
MEP Engineer
NC License #C-0914
150 Fayetteville Street
Suite 250
Raleigh, NC 27601
Telephone 919.296.2200
Consultant
Fire Protection
123 Street Address
Suite XXX
City, State, Zip
Telephone XXX.XXX.XXX
Facsimile XXX.XXX.XXXX
Consultant
AV Consultant
123 Street Address
Suite XXX
City, State, Zip
Telephone XXX.XXX.XXX
Facsimile XXX.XXX.XXXX
DESIGN DEVELOPMENT REVISED PRICING
JUNE 19, 2020DRAWING INDEX BUILDING CODE SUMMARY BUILDING CODE SUMMARY BUILDING CODE SUMMARY UCB
Sheet Revisions
Number
GENERAL
Sheet Name Latest Description Date
ENERGY SUMMARY FIRE PROTECTION REQUIREMENTS
2018 APPENDIX B
BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
BIOSCIENCES
G0.00 COVER 3 DD REVISED PRICING 2020-06-19 ENERGY REQUIREMENTS: (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) 4000 Paramount Pkwy
G0.02 APPENDIX B 3 DD REVISED PRICING 2020-06-19 (Reproduce the following data on the building plans sheet 1 or 2)
The following data shall be considered minimum and any special attribute required to meet the energy code
shall also be provided. Each Designer shall furnish the required portions of the project information for the
Suite 200 & 300
G1.01 VICINITY & LOCATION MAPS, PROJECT INFO. & SCOPE, GRAPHIC SYMBOLS & ABBREVIATION 3 DD REVISED PRICING 2020-06-19
G2.02 EGRESS & OCCUPANCY PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19
plan data sheet. If performance method, state the annual energy cost for the standard reference design vs FIRE RATING DESIGN # SHEET # SHEET # Morrisville, NC 27560
annual energy cost for the proposed design. SEPARATION DETAIL # FOR FOR FOR
PROVIDED
G2.03 EGRESS & OCCUPANCY PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 BUILDING ELEMENT DISTANCE REQ'D (W/___*
AND RATED RATED RATED Name of Project: UCB BIOSCIENCE FITOUT
Existing building envelope complies with code: No (FEET) SHEET # ASSEMBLY PENETRATION JOINTS
G5.01 PARTITION TYPE DETAILS 3 DD REVISED PRICING 2020-06-19 REDUCTION)
Address: UCB BIOSCIENCE FITOUT Zip Code: 27560
G6.01 DOOR ELEVATIONS AND DOOR SCHEDULE 3 DD REVISED PRICING 2020-06-19 Exempt Building: select one Provide code or statutory reference: Structural Frame,including
columns, girders, trusses 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Owner / Authorized Agent: -
G6.02 DOOR, FRAME AND HARDWARE SCHEDULES 3 DD REVISED PRICING 2020-06-19 Climate zone: 4A Bearing Walls Phone # - E-Mail -
G8.01 FINISH MATERIALS LEGEND 3 DD REVISED PRICING 2020-06-19 Method of Compliance: ASHRAE 90.1 Exterior
G9.11 INTERIOR RENDERINGS AND AXONOMETRICS 3 DD REVISED PRICING 2020-06-19 (If "Other" specify source here)
North 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Owned By: X Privately City/County State
THERMAL ENVELOPE (Prescriptive method only) East 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Code Enforcement Jurisdiction: X City MORRISVILLE County WAKE State
INTERIORS
West 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING 613 Hillsborough St. Tel 919.239.7828
I1.102 CONSTRUCTION PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Roof / Ceiling Assembly: (each assembly)
South 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING
Raleigh, NC 27603 Fax 919.239.7829
I1.103 CONSTRUCTION PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 United States
Description of assembly: RIGID INSULATION ON METAL DECK CONTACT:
I1.202 REFLECTED CEILING PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Interior 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING
I1.203 REFLECTED CEILING PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Nonbearing Walls and DESIGNER FIRM NAME LICENSE # PHONE # E-MAIL
Partitions
I1.302 FINISH PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Architectural: GENSLER CHAD PARKER 10105 919.239.7831 CHAD_PARKER@GENSLER.COM
U-Value of total assembly: Exterior walls
I1.303 FINISH PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 R-Value of insulation: 30 North >30' 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Civil: N/A
I1.402 FURNITURE PLAN - LEVEL 02 (FOR REFERENCE ONLY) 3 DD REVISED PRICING 2020-06-19 Skylights in each assembly: East >30' 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Electrical: OPTIMA ENGINEERING AMANDA E. ANDRASSY 39108 919.926.2200 abrooks@optimaengineering.com
U-Valye of skylight:
I1.403 FURNITURE PLAN - LEVEL 03 (FOR REFERENCE ONLY) 3 DD REVISED PRICING 2020-06-19 West >30' 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Fire Alarm: OPTIMA ENGINEERING AMANDA E. ANDRASSY 39108 919.926.2200 abrooks@optimaengineering.com
total square footage of skylights in each assembly:
I2.101 INTERIOR ELEVATIONS 3 DD REVISED PRICING 2020-06-19 South >30' Plumbing: OPTIMA ENGINEERING EVAN C. CONNELL 045488 919.926.2200 econnell@optimaengineering.com
0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING
I2.102 INTERIOR ELEVATIONS 3 DD REVISED PRICING 2020-06-19 Exterior Walls (each assembly) OPTIMA ENGINEERING EVAN C. CONNELL 045488 919.926.2200 econnell@optimaengineering.com
Interior walls and partitions 0 HR. ----- G5.01 N/A N/A N/A Mechanical:
I3.101 ENLARGED PLANS AND ELEVATIONS 3 DD REVISED PRICING 2020-06-19 Description of assembly: CONCRETE WITH RIGID INSULATION Floor Construction including Sprinkler-Standpipe: N/A
I3.102 ENLARGED PLANS AND ELEVATIONS 3 DD REVISED PRICING 2020-06-19 support beams and joists
0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Structural: N/A
I5.201 CEILING DETAILS 3 DD REVISED PRICING 2020-06-19
Floor Ceiling Assembly Retaining Walls>5' High: N/A
I5.301 MILLWORK DETAILS 3 DD REVISED PRICING 2020-06-19 U-Value of total assembly: Columns Supporting Floors Other:
I5.302 MILLWORK DETAILS 3 DD REVISED PRICING 2020-06-19 R-Value of insulation: 9.5 CI
Openings (windows or doors with glazing) Roof construction
including supporting beams ("Other" should include firms and individuals such as truss, precast, pre-engineered, interior designers, etc.)
U-Valye of assembly: .27
PLUMBING and joists 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING
Solar heat gain coefficient: .23
P0.01 PLUMBING LEGEND, INDEX AND NOTES 3 DD REVISED PRICING 2020-06-19 Projection factor: Roof Ceiling Assembly
P0.02 PLUMBING SCHEDULES 3 DD REVISED PRICING 2020-06-19 Door R-Value: Columns Supporting Roof 2018 NC BUILDING CODE: New Building Shell/Core X 1st time interior completion
P1.01 CONSTRUCTION - DRAINAGE PIPING PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Shaft Enclosures- Exit 1 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Addition Phased Construction - Shell/Core
Walls below grade (each assembly)
P1.02 CONSTRUCTION - DRAINAGE PIPING PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Shaft Enclosures- Other 1 HR. EXISTING EXISTING EXISTING EXISTING EXISTING
P2.01 CONSTRUCTION - SUPPLY PIPING PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Description of assembly:
Corridor Separation 0 HR. N/A N/A N/A N/A N/A 2018 NC EXISTING BUILDING CODE: Prescriptive Alteration Level I Historic Property
P2.02 CONSTRUCTION - SUPPLY PIPING PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Occupancy/Fire Barrier Separation 0 HR. N/A N/A N/A N/A N/A Repair Alteration Level II Change of Use
P3.01 WASTE & VENT RISER DIAGRAMS 3 DD REVISED PRICING 2020-06-19 Party/Fire Wall Separation N/A N/A N/A N/A N/A N/A
U-Value of total assembly: Chapter 14 Alteration Level III
P3.02 DOMESTIC RISER DIAGRAMS 3 DD REVISED PRICING 2020-06-19 Smoke Barrier Separation
R-Value of insulation: N/A N/A N/A N/A N/A N/A
CONSTRUCTED: (date) CURRENT OCCUPANCY(S) (Ch 3):
Smoke Partition
MECHANICAL Floors over unconditioned space (each assembly) RENOVATED: (date) PROPOSED OCCUPANCY(S) (Ch 3):
Tenant/Dwelling Unit/
M0.01 MECHANICAL LEGEND AND NOTES 3 DD REVISED PRICING 2020-06-19 Description of assembly: Sleeping Unit Seperation N/A N/A N/A N/A N/A N/A
M0.02 MECHANICAL SCHEDULES 3 DD REVISED PRICING 2020-06-19 OCCUPANCY CATEGORY (Table 1604.5): PROPOSED:
Incidental Use Separation N/A N/A N/A N/A N/A N/A
M1.01 DEMOLITION - MECHANICAL PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19
* Indicate section number permitting reduction
M1.02 DEMOLITION - MECHANICAL PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 U-Value of total assembly: BASIC BUILDING DATA
M2.01 CONSTRUCTION - MECHANICAL PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 R-Value of insulation: I-A II-A III-A IV V-A
PERCENTAGE OF WALL OPENING CALCULATION Construction Type:
M2.02 CONSTRUCTION - MECHANICAL PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 (check all that apply) I-B X II-B III-B V-B
M3.01 MECHANICAL DETAILS 3 DD REVISED PRICING 2020-06-19 Floors slab on grade
DEGREE OF OPENINGS
ALLOWABLE AREA ACTUAL SHOWN ON PLANS Sprinklers: No Partial X NFPA 13 NFPA 13R NFPA 13D
Description of assembly: CONCRETE SLAB ON GRADE PROTECTION
(%) (%)
(TABLE 705.8) Standpipes: No Class: I II X III X WET DRY
ELECTRICAL
E0.01 ELECTRICAL LEGEND AND NOTES 3 DD REVISED PRICING 2020-06-19 Fire District: No Yes Flood Hazard Area: No Yes
E0.02 ELECTRICAL SPECIFICATIONS 3 DD REVISED PRICING 2020-06-19 U-Value of total assembly: Special Inspection Required: No Yes
E1.01 DEMOLITION - ELECTRICAL PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 R-Value of insulation: 15
Horizontal/vertical requirement:
E1.02 DEMOLITION - ELECTRICAL PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Slab heated: GROSS BUILDING AREA TABLE:
E2.01 CONSTRUCTION - LIGHTING PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 FLOOR EXISTING (SQ FT) NEW (SQ FT) SUB-TOTAL
LIFE SAFETY SYSTEM REQUIREMENTS
E2.02 CONSTRUCTION - LIGHTING PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 3rd Floor 31,639
E3.01 CONSTRUCTION - POWER PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 STRUCTURAL DESIGN
(PROVIDE ON SHEET 1 OR 2 OF THE STRUCTURAL SHEETS) Emergency Lighting: No X Yes 2nd Floor 31,639
E3.02 CONSTRUCTION - POWER PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19
Exit Signs: No X Yes Mezzanine
E4.01 CONSTRUCTION - EQUIPMENT CONNECTIONS PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 DESIGN LOADS:
Fire Alarm: No X Yes 1st Floor 31,639
E4.02 CONSTRUCTION - EQUIPMENT CONNECTIONS PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19
Importance Factors: Wind (Iw) Smoke Detection Systems: No X Yes Basement
E5.01 ELECTRICAL DETAILS 3 DD REVISED PRICING 2020-06-19 Snow (IS )
E5.02 ELECTRICAL DETAILS 3 DD REVISED PRICING 2020-06-19 Seismic (I E) Carbon Monoxide Detection: X No Yes -
-
Date Description
E5.03 ELECTRICAL DETAILS 3 DD REVISED PRICING 2020-06-19 Panic Hardware: X No Yes
E5.04 PANEL SCHEDULES 3 DD REVISED PRICING 2020-06-19 Live Loads: Roof psf - 2 2020-04-24 DD PRICING
E5.05 PANEL SCHEDULES 3 DD REVISED PRICING 2020-06-19 Mezzanine psf
Floor LIFE SAFETY PLAN REQUIREMENTS TOTAL BUILDING 94,917 3 2020-06-19 DD REVISED PRICING
psf
E5.06 ELECTRICAL SCHEDULES 3 DD REVISED PRICING 2020-06-19
FA0.01 FIRE ALARM LEGEND AND NOTES 3 DD REVISED PRICING 2020-06-19 Life safety Plan Sheet #: G2.02 & G2.03 ALLOWABLE AREA
Ground Snow Load: psf
FA1.01 DEMOLITION - FIRE ALARM PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 X Fire and/or smoke rated wall locations (Chapter 7) Primary Occupancies Classification(s):
Wind Load: Basic Wind Speed mph (ASCE-7)
FA1.02 DEMOLITION - FIRE ALARM PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Assumed and real property line locations (if not on the site plan) Assembly A-1 A-2 A-3 A-4 A-5
Exposure Category Exterior wall opening area with respect to distance to assumed property lines (705.8)
FA2.01 CONSTRUCTION - FIRE ALARM PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Business X
X Occupancy Use for each area as it relates to occupant load calculation (Table 1004.1.2)
FA2.02 CONSTRUCTION - FIRE ALARM PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Educational
SEISMIC DESIGN CATEGORY: A B C D X Occupant loads for each area F-1 Moderate F-2 Low
Factory
X Exit access travel distance (1017) Hazardous H-1 Detonate H-2 Deflagrate H-3 Combust H-4 Health H-5 HPM
Provide the following Seismic Design Parameters:
X Common path of travel distances (Tables 1006.2.1 & 1006.3.2(1)) Institutional
Occupancy Category (Table 1604.5) I II III IV I-1 I-2 I-3 I-4
X Dead end lengths (1020.4) I-1 Condition
Spectral Response Acceleration Ss %g S1 %g 1 2
X Clear exit widths for each exit door I-2 Condition
Site Classification (ASCE 7) A B C D E F 1 2
X Maximum calculated occupant load capacity each exit door can accommodate base on egress - I-3 Condition
Data Source: 1 2 3 4 5
Field Test Presumptive Historical Data width (1005.3) Mercantile
Basic structural system (check one) X Actual occupant load for each exit door Residential R-1 R-2 R-3 R-4
Bearing Wall Dual w/Special Moment Frame A separate schematic plan indicating where fire rated floor/ceiling and/or roof structure is provided Storage S-1 Moderate S-2 Low High-piled
Building Frame Dual w/Intermediate R/C or Special Steel for porposes of occupancy separation
Moment Frame Inverted Pendulum Location of doors with panic hardware (1010.1.10)
Parking Garage: Open Enclosed Repair Garage
Location of doors with delayed egress locks and amount of delay (1010.1.9.7)
Analysis Procedure: Simplified Equivalent Lateral Force Dynamic Utility and Miscellaneous
X Location of doors with electromagnetic egress locks (1010.1.9.9)
Architectural, Mechanical, Components anchored? Yes No Location of doors equipped with hold-open devices Accessory Occupancy Classification(s):
Location of emergency escape windows (1030) Incidental Uses (Table 509):
LATERAL DESIGN CONTROL: Earthquake Wind
The square footage of each fire area (202) This seperation is not exempt as a Non-Seperated Use (see exceptions).
SOIL BEARING CAPACITIES: The square footage of each smoke comparment for Occupancy Classification I-2 (407.5)
Field Test (provide copy of test report) Note any code exceptions or table notes that may have been utilized regarding the items above Special Uses (Chapter 4 - List Code Sections):
psf
Presumptive bearing capacity psf Special Provisions (Chapter 5 - List Code Sections):
Pile size, type, and capacity
Mixed Occupancy: Separation: Exception:
ACCESSIBLE DWELLING UNITS
(SECTION 1107) Select one
MECHANICAL DESIGN ACCESSIBLE ACCESSIBLE TYPE A TYPE A TYPE B TYPE B TOTAL
(PROVIDE ON THE MECHANICAL SHEETS IF APPLICABLE) TOTAL Actual Area of Occupancy A + Actual Area of Occupancy B
UNITS UNITS UNITS UNITS UNITS UNITS ACCESSIBLE UNITS < 1
UNITS Allowable Area of Occupancy A Allowable Area of Occupancy B
REQUIRED PROVIDED REQUIRED PROVIDED REQUIRED PROVIDED PROVIDED
MECHANICAL SYSTEM, SERVICE SYSTEMS AND EQUIPMENT
+ + = < 1.00
Thermal zone
Winter dry bulb: _______________________________
Summer dry bulb: _______________________________
ACCESSIBLE PARKING (A) (B) (C) (D)
(SECTION 1106) Description 4
Interior design conditions Story Bldg Area Per Table 506.2 Area For Frontage Allowable Area Per
Winter dry bulb: _______________________________ No. And Use Story (Actual) Area Increase 1,5 Story or Unlimited 2,3
Summer dry bulb: _______________________________
Total # of Parking Spaces # of Accessible Spaces Provided Total #
Lot or Parking
REFER TO MECHANICAL DRAWINGS M SERIES
Relative humidity: _______________________________
Area Required Provided
Regular with 5'
Access Aisle
VAN SPACES WITH
132" Access 8' Access
Accessible
Provided
2 BUSINESS 31,639 69,000 N/A 69,000
Building heating load: Aisle Aisle 3 BUSINESS 31,639 69,000 N/A 69,000
BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt
Building cooling load:
Mechanical Spacing Conditioning System
Total 424 (EXIST) 6 4 10 Seal / Signature
Unitary
description of unit:
1 Frontage area increases from Section 506.2 are computed thus:
heating efficiency: a.Perimeter which fronts a public way or open space having 20 feet minimum width = _____ ft (F)
PLUMBING FIXTURE REQUIREMENTS b.Total Building Perimeter = _____ ft (P)
colling efficiency: (TABLE 2902.1)
size category of unit:
BOILER
size category. If oversized, state reason: USE
WATERCLOSETS
URINALS
LAVATORIES SHOWERS DRINKING FOUNTAINS
c.Ratio (F/P) = _____ (F/P)
d.W = Minimum width of public way = _____ ft (W)
2 Unlimited area applicable under conditions 507.
NOT FOR
/ TUBS
Chiller
size category. If oversized, state reason: EXIST'G
MALE FEMALE UNISEX
6 10 4
MALE FEMALE UNISEX
6 6
REGULAR
2
ACCESSIBLE
2
3 Maximum Building Area = total number of stories in the building x D (maximum 3 stories) (506.2).
4 The maximum area of open parking garages must comply with 406.5.4. The maximum area of air traffic
control towers must comply with 412.3.1.
CONSTRUCTION
5 Frontage increase is based on the unsprinklered area value in Table 506.2.
List equipment efficiencies: SPACE NEW 2 6 6 2 1 2
REQ'D 6 11 4 6 6 3 4
ALLOWABLE HEIGHT Project Name
ELECTRICAL DESIGN
(PROVIDE ON THE ELECTRICAL SHEETS IF APPLICABLE) SPECIAL APPROVALS
ALLOWABLE SHOWN ON PLANS CODE REFERENCE
UCB BIOSCIENCES
ELECTRICAL SYSTEM, AND EQUIPMENT Special Approval: (Local Jurisdiction, Department of Insurance, OSC, DPI, DHHS, etc., describe below)
Building Height in Feet (Table 504.3) 75'
Method of compliance: Building Height in Stories (Table 504.4) 4 Project Number
Provide code reference if the "Shown on Plans"quantity is not based on Table 504.3 or 504.4.
Lighting Schedule (each fixture type)
lamp type required in fixture 090.0338.000
REFER TO ELECTRICAL DRAWINGS E SERIES
number of lamps in fixture
ballast type used in the fixture Description
number of ballasts in fixture
total wattage per fixture APPENDIX B
total interior wattage specified vs. allowed (whole building of space by space)
total exterior wattage specified vs. allowed
Additional Prescriptive Compliance
506.2.1 More Efficient Mechanical Equipment
506.2.2 Reduced Lighting Power Density Scale
506.2.3 Energy Recovery Ventilation System
506.2.4 Higher Efficiency Service Water Heater
12" = 1'-0"
506.2.5 On-Site Supply of Renewable Energy
506.2.6 Automatic Daylighting Control Systems
6/19/2020 5:16:50 PM
G0.02
© 2020 GenslerABBREVIATIONS GRAPHIC SYMBOLS GRAPHIC SYMBOLS GRAPHIC SYMBOLS VICINITY MAP
UCB
& AND
SECTION INDICATIONS REFLECTED CEILING GENERAL
ACCESS
ACOUS
ACCESSORY
ACOUSTIC(AL)
ELAST
ELEC
ELASTOMERIC
ELECTRICAL
JAN JANITOR RD
RDL
ROOF DRAIN
ROOF DRAIN LEADER ACOUSTICAL CEILING TILE
PLAN NORTH BIOSCIENCES
AFF ABOVE FINISHED FLOOR EMBED EMBEDD(ED)(ING) KIT KITCHEN RDR READER ACOUSTICAL CEILING AND GRID TRUE NORTH (IF DIFFERENT THAN PLAN NORTH)
4000 Paramount Pkwy
AL ALUMINUM ENGR ENGINEER(ED) RECES RECESSED Suite 200 & 300
ALT ALTERNATE ENTR ENTRANCE LAV LAVATORY RECPT RECEPTACLE ALUMINUM
ANNUNC ANNUNCIATOR EQ EQUAL LB POUND REF REFER(ENCE)
AREA NOT IN CONTRACT / Morrisville, NC 27560
OUTSIDE THE SCOPE OF WORK
ANOD ANODIZED EQUIP EQUIPMENT LP LOW POINT REFL REFLECTED BRICK GYPSUM BOARD OR PLASTER
APPL APPLIANCE EXIST EXISTING LT LIGHT REFR REFRIGERATOR
ARCH ARCHITECT(URAL) EXP JT EXPANSION JOINT LVLG LEVELING REINF REINFORCED(D)(ING)(MENT) xx'-xx"
1
AUTO AUTOMATIC EXPS EXPOSED(D) LVT LOUVER REQD REQUIRED CARPET COLUMN GRID REFERENCE NUMBER
CEILING HEIGHT CHANGE SYMBOL
AVG AVERAGE EXT EXTERIOR £ BRITISH POUND (CURRENCY) RESIL RESILIENT COLUMN GRID LINES AND REFERENCE NUMBER
xx'-xx"
RESIS RESIST(ANT)(IVE) CONCRETE
X'-X" EXISTING CONSTRUCTION TO REMAIN
BD BOARD FAB FABRICATION MAX MAXIMUM RFG ROOFING FINISHED CEILING HEIGHT
BLDG BUILDING FD FLOOR DRAIN MECH MECHANICAL RM ROOM EXISTING CONSTRUCTION TO BE DEMOLISHED
CONCRETE MASONRY UNIT GRID STARTPOINT 613 Hillsborough St. Tel 919.239.7828
BLKG BLOCKING FE FIRE EXTINGUISHER MEMB MEMBRANE RO ROUGH OPENING NEW PARTITION Raleigh, NC 27603 Fax 919.239.7829
BOLLD BOLLARD FE&C FIRE EXTINGUISHER AND CABINET MET METAL APC1 CEILING FINISH TAG 1 HR FIRE RATED PARTITION United States
BRDLM BROADLOOM FHC FIRE HOSE AND CABINET MEZZ MEZZANINE SCR SCRIBE CUT STONE
CEILING TAG 2 HR FIRE RATED PARTITION
BU BUILT UP FIN FINISH MFD MANUFACTURED SECUR SECURITY
FLDG FOLDING MFR MANUFACTURER SF SQUARE FEET APC1 CEILING FINISH 3 HR FIRE RATED PARTITION
EARTH 10'-0" CEILING HEIGHT
CAB CABINET FLR FLOOR(ING) MIN MINIMUM SG SINGLE 4 HR FIRE RATED PARTITION
CEM CEMENT(ITIOUS) FPLC FIREPLACE MISC MISCELLANEOUS SHORG SHORING
S SPEAKER MILLWORK
CER CERAMIC FR FIRE RAT(ING)(ED) MLWK MILLWORK SIM SIMILAR FABRIC WRAPPED PANEL
CIP CAST-IN-PLACE FRMG FRAMING MOIST MOISTURE SST STAINLESS STEEL MILLWORK ABOVE
SECURITY CAMERA
CLG CEILING FURN FURNITURE MOT MOTOR(IZED) STD STANDARD
GLASS
CMU CONCRETE MASONRY UNIT FWC FABRIC WALL COVERING MTD MOUNTED STL STEEL DETAIL NUMBER
EXIT SIGN XX
COATG COATING FXD FIXED STRFR STOREFRONT
GRAVEL XX.XXX SHEET NUMBER
COILG COILING FXTR FIXTURE NIC NOT IN CONTRCT STRUCT STRUCTURAL E DENOTES EXISTING TO REMAIN SIM
CONC CONCRETE NO NUMBER SURF SURFACE DESCRIPTION OF SIMILAR OR OPPOSITE
CONSTR CONSTRUCTION GA GAUGE NTS NOT TO SCALE SUSP SUSPENDED R DENOTES EXISTING TO BE RELOCATED
GYPSUM PLASTER
CONT CONTINUOUS(ATION) GFRC GLASS FIBER REINFORCED SYS SYSTEM(S) AREA TO BE DETAILED
CONCRETE HINGED ACCESS PANEL
CONTR CONTRACT(OR) OPNG OPENING(S)
COV COVER GFRG GLASS FIBER REINFORCED GYPSUM OPR OPERABLE T&G TOUNGUE AND GROOVE INSULATION (LOOSE OR BATT)
LOCATION ON SHEET WHERE ELEVATION IS SHOWN
CPT CARPET GFRP GLAS FIBER REINFORCED PLASTER ORD OVERFLOW ROOF DRAIN THK THICK 1
GL GLASS ORNA ORNAMENTAL TLT TOILET
LIGHT FIXTURES DIRECTION OF ELEVATION LOCATION MAP
INSULATION (RIGID)
$ DOLLAR (US CURRENCY) GR GRAD(E)(ING) OVFL OVERVLOW TRAF TRAFFIC LAY-IN LIGHT FIXTURE 2 A11.XX SHEET NUMBER WHERE ELEVATION IS SHOWN
DBL DOUBLE GYP GYPSUM OVHD OVERHEAD TRANS TRANSPARENT
LINEAR STRIP FIXTURE INTERIOR AND EXTERIOR ELEVATION MARKER
DEPT DEPARTMENT TRTD TREATED METAL
DES DESIGN(ED) HD HEAD PBD PARITICLE BOARD TYP TYPICAL LINEAR PENDANT FIXTURE 1
DET DETAIL HDWD HARDWOOD PEDR PEDESTRIAN RECESSED DOWNLIGHT REVISION REFERENCE NUMBER
PLASTIC
DF DRINKING FOUNTAIN HDWE HARDWARE PLAM PLASTIC LAMINATE UNDRLAY UNDERLAYMENT RECESSED ADJUSTABLE DOWNLIGHT
DIA DIAMETER HM HOLLOW METAL PLAS PLASTER UNO UNLESS NOTED OTHERWISE REVISION CLOUD ENCLOSING AREA REVISED
PLYWOOD RECESSED WALL WASHER
DIFF DIFFUSER HORIZ HORIZONTAL PLSTC PLASTIC UTIL UTILITY
HP HIGH POINT TRACK LIGHTING NAME
DIM DIMENSION PLYWD PLYWOOD ROOM NAME
HVAC HEATING, VENTILATIING, AND AIR SURFACE MOUNTED LIGHT FIXTURE
DISP DISPENSER PNL PANEL VEH VECHICLE PRE-CAST PANELS 1234 ROOM NUMBER
DIV DIVISION CONDITIONING POLYST POLYSTRENE VERT VERTICAL AREA ROOM AREA (SQ FT)
WALL SCONCE
DN DOWN PORT PORTABLE VIF VERIFY IN FIELD 01 SHEETNOTE REFERENCE
INFILTR INFILTRATION SAND OR GROUT MECHANICAL FIXTURES
DR DOOR PREFAB PREFABRICATED
DSCON DISCONNECT INFO INFORMATION PREFIN PREFINISHED W/ WITH 1 A3A WALL TYPE REFERENCE
INSTRUM INSTRUMENT(ATION) RETURN AIR
DWG DRAWER PRTECN PROTECTION W/O WITHOUT STONE FIRE RATING
INSUL INSULATION PTN PARTITION WC WATER CLOSET SUPPLY AIR XXX DOOR REFERENCE NUMBER (REFER TO DOOR SCHEDULE)
INT INTERIOR WD WOOD
INTLK INTERLOCK(ING) WOOD (FINISHED )
WDW WINDOW CIRCULAR DIFFUSER XX DOOR NUMBER
WT WEIGHT LINEAR DIFFUSER XX DOOR TYPE
WTRPRF WATERPROOFING WOOD (CONTINUOUS MEMBER) DOOR NUMBER
XXX
X X DOOR TYPE | HARDWARE TYPE
WOOD (INTERRUPTED MEMBER
XX WINDOW REFERENCE NUMBER (REFER TO WINDOW SCHEDULE)
MW01 MILLWORK REFERENCE NUMBER (REFER TO MILLWORK SCHEDULE)
DEVICE MOUNTING DIAGRAMS PROJECT SCOPE
ELEVATION DATUM REFERENCE
FOLLOWING ARE THE PLANS OUTLINING THE SCOPE OF WORK REQUIRED FOR INTERIOR TENANT WORK TO
+6" INCLUDE SELECT DEMOLITION & CONSTRUCTION OF NEW PARTITIONS, CEILINGS, FINISHES, MECHANICAL, Date Description
NOTE:
FLOOR ELEVATION TRANSITION ELECTRICAL, PLUMBING & FIRE PROTECTION AS INDICATED ON DRAWINGS.
IF THE COUNTER IS DEEPER THAN 24", PROVIDE 0" 2 2020-04-24 DD PRICING
EDGE OF WALL, DOOR EDGE OF WALL, DOOR CONVENIENCE OUTLETS ON THE END WALL ACCESSIBLE
FRAME, OR OPENING FRAME, OR OPENING TOILET ACCESSORY TAG THE DRAWINGS, IN CONCERT WITH THE PROJECT MANUAL, COMPRISE THE CONTRACT DOCUMENTS 3 2020-06-19 DD REVISED PRICING
REACH RANGE. TA__
OUTLINING THE INTENT OF THE ARCHITECT, AND MAY BE SUPPLEMENTED BY FURTHER INFORMATION
EQ P__ PLUMBING FIXTURE TAG ISSUED BY ARCHITECT.
UNLESS SPECIFIC DIMENSIONS ARE INDICATED A B WALL DEVICE MOUNTING HEIGHTS
ALIGN CENTERS OF ALIGN CENTERS OF DEVICES EQ EQ
DEVICES OR GROUPS OF OR GROUPS OF DEVICES. (TYPICALLY TO COORDINATE WITH EQUIPMENT), EQUIPMENT TAG THE DRAWINGS ARE ARRANGED IN GENERAL TO SPECIFIC ORDER, FOLLOWING A TOP TO BOTTOM, RIGHT
B DEVICE TYPE HEIGHT 1__
DEVICES. CENTER DEVICES OR GROUPS OF DEVICES WITHIN TO LEFT FORMAT. CONTRACTORS ARE ADVISED TO READ AND FAMILARIZE THEMSELVES WITH THE
WIDTH OR DEPTH OF MILLWORK ALL DEVICES INFORMATION IN THE PROJECT MANUAL, AS WELL AS THE GENERAL LEGENDS CONTAINED IN THE G SERIES
GANG TOGETHER MULTIPLE
OCCURING AT FIRE ALARM STROBE/HORN 7' - 6" OF DRAWINGS, PRIOR TO REVIEW OF THE PLANS, ELEVATIONS AND DETAILS. ADVISE THE ARCHITECT
GANG TOGETHER MULTIPLE DEVICES OF THE SAME
EQ EQ 8" ABOVE COUNTERTOP OR (IF MILLWORK SHALL BE NON-ADJUSTABLE SENSOR 4' - 6" WHERE INTENT IS NOT CLEARLY PERCEIVED, PRIOR TO PROCEEDING WITH WORK.
DEVICES OF THE SAME TYPE.
HORIZONTAL
TYPE. APPLICABLE) ABOVE TOP OF
COUNTER'S BACKSPLASH ORIENTATION
THERMOSTAT
INTERCOM
3' - 10"
3' - 10"
FINISH
4" SECURITY ALARM PANEL 3' - 10" XXXX WALL FINISH TAG
A CARD READER 3' - 6"
EQ XXXX BASE FINISH TAG
WHERE INCLUDED FOR UNDER- FIRE ALARM PULL STATION 3' - 6"
COUNTER EQUIPMENT, COORDINATE EXTENT OF FINISH TYP.
8" DOOR RELEASE BUTTON 3' - 6"
DEVICE PLACEMENT WITH EQUIPMENT
LOCATIONS. FOR CONVENIENCE TELEPHONE 3' - 6" WALL FINISH TAG
XXXX
DEVICES, CENTER AND SPACE EVENLY ROOM SCHEDULER 3' - 6"
ALONG WIDTH OF COUNTER LIGHT CONTROL 3' - 2"
POWER AND DATA DEVICES AV CONTROL PANEL 3' - 2" XXXX SPECIAL FINISH TAG
NOT ASSOCIATED WITH DOOR OPERATOR BUTTON 3' - 2"
MILLWORK SHALL BE IN TYPICAL POWER RECEPTACLE 1' - 6" XXXX FLOOR FINISH TAG
VERTICAL ORIENTATION
TYPICAL DATA JACK 1' - 6"
AT COLUMNS OR BETWEEN DOORS, FRAMES, AT EDGE OF WALL, DOOR, FRAME, OPENING, ALL HEIGHTS TO CENTERLINES OF DEVICES CHANGE IN FLOOR FINISH
OPENINGS, OR OTHER ELEMENTS OR OTHER ELEMENTS
SIGNAGE MOUNTING DIAGRAMS SHOWER MOUNTING DIAGRAMS PLUMBING FIXTURE AND ACCESSORY MOUNTING DIAGRAMS
5' - 0" MINIMUM
BACK WALL
2' - 6" MINIMUM
FINISHED FACE OF BACK WALL FINISHED FACE OF SIDE WALL
11" 1' - 4"
3' - 4"
SIGN
CONTROL AREA
1' - 0" 3' - 6"
BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt
1' - 6"
3' - 0" 6" MIRROR
10"
3' - 0" MINIMUM
GRAB BAR Seal / Signature
6"
INACTIVE LEAF ACTIVE LEAF
REFLECTING SURFACE
CLEAR AREA
3' - 4" - BOTTOM OF
5' - 0"
2' - 11" TYPICAL
2' - 11" TYPICAL
1' - 6" 8" 8"
3' - 4" CLEAR AREA
NOT FOR
3' - 2"
3' - 0"
2' - 10"
2' - 3" MIN
2' - 3" MIN
2' - 0"
5' - 0" MINIMUM
1' - 4"
1' - 5"
7"
11" 11"
FINISHED FLOOR
CONSTRUCTION
ACCESSIBLE SHOWER ACCESSIBLE TOILET URINAL - TYPICAL URINAL - ACCESSIBLE ACCESSIBLE TOILET DRINKING FOUNTAIN LAVATORY
DOUBLE DOOR WITH ONE ACTIVE LEAF BACK WALL SIDE WALL BACK WALL
PLAN VIEW - ROLL-IN SHOWER TYPE
ALL DIMENSIONS ARE TO FACE OF FINISH Project Name
EQ EQ
3' - 0"
2" 2"
UCB BIOSCIENCES
BACK WALL
CURTAIN CURTAIN ROD Project Number
CONTROL WALL
ROD SHOWER HEAD
090.0338.000
3' - 0"
3' - 0"
8"
3"
Description
SIGN CONTROL SOAP DISH OR SHELF,
AREA IF APPLICABLE VICINITY & LOCATION MAPS,
1' - 6"
1' - 6" PROJECT INFO. & SCOPE, GRAPHIC
7' - 0"
10"
GRAB BAR CONTROLS SYMBOLS & ABBREVIATION
3' - 0" MINIMUM
4' - 10" - TYPICAL
GRAB BAR HEIGHT FOR REFERENCE
3' - 10" - ACCESSIBLE
5' - 6"
4' - 6"
CLEAR AREA Scale
2' - 11" TYPICAL
4' - 0"
4' - 6"
4' - 0"
SEAT
3' - 9"
3' - 6"
3' - 4"
3' - 4"
3' - 3"
3' - 2"
As indicated
3' - 0"
2' - 6"
1' - 6 1/2"
1' - 7"
1' - 7"
6/19/2020 5:17:04 PM
4' - 0" MINIMUM
FINISHED FLOOR
SINGLE DOOR OR
DOUBLE DOOR WITH TWO ACTIVE LEAVES
ACCESSIBLE SHOWER
PLAN VIEW - TRANSFER SHOWER TYPE
ALL DIMENSIONS ARE TO FACE OF FINISH
BACK WALL CONTROL WALL TYPICAL (NON-ACCESSIBLE) SHOWER
CONTROL WALL
WASTE / TOWEL
COMBO UNIT
TOWEL
DISPENSER
WASTE
RECEPTACLE
SANITARY
VENDOR
COMBINATION
DISPENSER
TOILET TISSUE
DISPENSER
SANITARY
DISPOSAL
SEAT COVER
DISPENSER
ROBE, COAT, OR
TOWEL HOOK
HAND
DRYER
SOAP
DISPENSER
FEC OR FHVC SHELF & MOP
HOLDER
G1.01
© 2020 GenslerUCB
BIOSCIENCES
4000 Paramount Pkwy
Suite 200 & 300
Morrisville, NC 27560
613 Hillsborough St. Tel 919.239.7828
Raleigh, NC 27603 Fax 919.239.7829
United States
BUBBLE MAIL
RECEPTION 2002
2047 FURN
2001
STORAGE
FEC
2022
TRAINING B LG CONF
BUBBLE 2021B TRAINING A 2003
2045 2021A
COMMON PATH OF TRAVEL
36' - 0"
LIBRARY INTERVIEW
2040 2011
BUBBLE LG CONF
2043 2003
=
E /3 430 SF
C
T AN TION
IS A
A L D PAR
N E
PIONEER
IAGO XIT SCOLLAB
BUBBLE D E
3" IN 2010
2041 '0 - 9" M
20 6' -
6
SM CONF
2004
PHONE
2032 LIBRARY
VESTIBULE
2030
5' - 6"
PHONE TRAVEL DISTANCE
2031 115' - 5" FEC
WAR ROOM
34 0.15
2012
BUBBLE PHONE PHONE 48 0.2 145
FEC 2051 2024 2023
187
WELLNESS RESTROOM RESTROOM JAN
2" STORAGE
2018 2017 2015
92' -
= 2012A
ON
BUBBLE RATI
A
2053 EP
EX IT S
COLLAB CORRIDOR
2050 2013 ELEC
217 SF WELLNESS
2019
48 0.2
BUBBLE 188 STORAGE STORAGE SERVER
2055 2020 2016 2014 Date Description
2 2020-04-24 DD PRICING
3 2020-06-19 DD REVISED PRICING
PHONE
2052 FEC
PHONE BUBBLE 34 0.15
2054 2061
145
FUTURE
BUBBLE BUSINESS USE
2063 TENANT
LIBRARY 15090 SF
2060
BUBBLE
2065
BUBBLE
2067
BUBBLE
2069
01 EGRESS & OCCUPANCY PLAN - LEVEL 02
SCALE: 1/8" = 1'-0"
BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt
GRAPHIC SYMBOLS LEGEND OCCUPANT LOAD CALCULATION - LEVEL 02 EGRESS REQUIREMENTS - LEVEL 02 TOILET FIXTURE REQUIREMENTS - LEVEL 02 GENERAL NOTES Seal / Signature
AREA TOTAL GROSS AREA OF TENANT - ENTIRE FLOOR: APPROX. 31,639 SF FIXTURES REQUIRED PROVIDED 1. AREAS TONED IN SOLID GRAY ARE NOT IN CONTRACT.
EGRESS WIDTH LOAD FACTOR IBC TABLE 1004.1.1
TRAVEL DISTANCE 2. FIRE EXTINGUISHER, EXIT SIGN, & FIRE ALARM DEVICE LOCATIONS ARE SHOWN FOR
TOTAL AREA IN SCOPE: APPROX. 12,924 SF WATER CLOSETS 8 10 REFERENCE, INTENDED EGRESS, & DESIGN INTENT. FINAL DEVICE LOCATIONS ARE
00 00 ASSEMBLY - UNCONCENTRATED SUBJECT TO REVIEW WITH FIRE MARSHAL/INSPECTORS. REVIEW WITH INSPECTORS
COMMON PATH OF TRAVEL
ONE-HOUR FIRE RATED PARTITION
00 (15NSF/OCCUPANT):
BREAK 217 NET SF 15 OCC
TENANT OCCUPANCY: 138 OCCUPANTS
290 OCCUPANTS FULL FLOOR
LAVATORIES 5 6 DURING ROUGH-IN TO CONFIRM LOCATIONS & QUANTITIES.
NOT FOR
LOAD CAPACITY IBC TABLE 1004.1.1 DRINKING FOUNTAINS 3 3
EXIT ACCESSORY (300 GSF/OCCUPANT):
STORAGES & SERVER 418 GROSS SF 2 OCC EGRESS WIDTH REQUIREMENTS: IBC TABLE 1005.1 EXCEPTION 2
IPC SECTION 410.1
CONSTRUCTION
OTHER EGRESS COMPONENTS
BUSINESS (100 GSF/OCCUPANT): REQUIRED (.15 IN/OCCUPANT): 44 INCHES
GENERAL OFFICE 15,090 GROSS SF 121 OCC PROVIDED AT EXIT STAIR DOORS: 68 INCHES
EXIT STAIR WIDTH Project Name
TOTAL TENANT OCCUPANT 138 OCC REQUIRED (.2 IN/OCCUPANT) 58 INCHES
OCCUPANCY CLASSIFICATION LEGEND PROVIDED AT EXIT STAIRS: 92 INCHES UCB BIOSCIENCES
WHITE BOX TENANT 15,089 GROSS SF 151 OCC
ELECTRICAL & JANITOR 228 GROSS SF 1 OCC MINIMUM WIDTH OF EGRESS CORRIDOR REQUIRED: 44 INCHES
ASSEMBLY (NON-CONCENTRATED) - 1 PERSON/15SF IBC 1018.2
TOTAL OCCUPANT 290 OCC Project Number
MINIMUM WIDTH OF EGRESS CORRIDOR PROVIDED: 60 INCHES
BUSINESS - 1 PERSON/100 SF
MINIMUM NUMBER OF EXITS REQUIRED: 2 EXITS
090.0338.000
IBC TABLE 1021.1 Description
ACCESSORY (STORAGE / MECHANICAL) - 1 PERSON/300 SF
NUMBER OF EXITS PROVIDED: 2 EXITS EGRESS & OCCUPANCY PLAN -
MAXIMUM LENGTH OF EGRESS TRAVEL: 300 FEET LEVEL 02
IBC TABLE 1016.1
MAXIMUM COMMON PATH OF TRAVEL: 100 FEET
IBC 1014.3 EXCEPTION 1 Scale
MAXIMUM DEAD END CORRIDOR: 50 FEET As indicated
IBC 1018.4 EXCEPTION 2
ACCESS CONTROLLED HARDWARE (ELECTROMAGNETIC LOCK - FAIL OPEN) MEETING ALL
6/19/2020 5:17:31 PM
REQUIREMENTS OF IBC 1008.1.4.4.
EGRESS & OCCUPANCY CALCULATION - LEVEL 02 G2.02
02 SCALE: 1 1/2" = 1'-0"
© 2020 GenslerUCB
BIOSCIENCES
4000 Paramount Pkwy
Suite 200 & 300
Morrisville, NC 27560
613 Hillsborough St. Tel 919.239.7828
Raleigh, NC 27603 Fax 919.239.7829
United States
HR SUITE PHONE PHONE
TREADMILL 3096 3091 3081
3021
COMMON PATH OF TRAVEL
33' - 8"
OPEN BUBBLE BUBBLE BUBBLE
OFFICE 3023 3093 3083
OPEN OPEN
3020 WORK CAFE OFFICE
3001 OFFICE
3090 3080
HUDDLE HUDDLE HUDDLE
HUDDLE
3024 VENDING 3094 3084
3097
3002 COLLAB
34 0.15 34 0.15 34 0.15 34 0.15 BOOTHS
25 25 25 25 3095
34 0.15
FEC FEC FEC FEC
246
SM CONF
3085 LG CONF
MD CONF MD CONF
PHONE STORAGE 48 0.2 3076
3026 3025
3008 3003 450 SF
246
HALO
165 SF 3"
48 0.2
CONFERENCE
271' - JAN
3006 /3 =
N AL
247 GO
LL DIA
ELEC ERA
COPY/COLLAB OV
ELEVATOR COPY/COLLAB
3028 IT 3078
LOBBY
607 SF WORKROOM 3000
3005
53' - 2"
EP ARATION = 1
SM CONF SM CONF STORAGE
SERVER EXIT S PHONE
3036 3035 3004 MD CONF Date Description
3048 3067
3075
2 2020-04-24 DD PRICING
34 0.15
3 2020-06-19 DD REVISED PRICING
FEC FEC EXIST. FEC
TRAVEL DISTANCE COLLAB
247 FEC 164' - 4" BOOTHS
3065
BUBBLE
3054
HUDDLE HUDDLE
3064 3074
BUBBLE
3053
OPEN OPEN OPEN
OFFICE OPEN OFFICE
BUBBLE BUBBLE OFFICE OFFICE
3030 3070
3033 3043 3040 3060 BUBBLE
CREATIVE 3063
WORK BUBBLE
3050 3052
BUBBLE BUBBLE
3032 3042 BUBBLE
3072
HUDDLE
3051
PHONE PHONE TREADMILL TREADMILL
3031 3041 3061 3071
01 EGRESS & OCCUPANCY PLAN - LEVEL 03
SCALE: 1/8" = 1'-0"
BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt
GRAPHIC SYMBOLS LEGEND OCCUPANT LOAD CALCULATION - LEVEL 03 EGRESS REQUIREMENTS - LEVEL 02 TOILET FIXTURE REQUIREMENTS - LEVEL 02 GENERAL NOTES Seal / Signature
AREA TOTAL GROSS AREA OF TENANT - ENTIRE FLOOR: APPROX. 31,639 SF FIXTURES REQUIRED PROVIDED 1. AREAS TONED IN SOLID GRAY ARE NOT IN CONTRACT.
EGRESS WIDTH LOAD FACTOR IBC TABLE 1004.1.1
TRAVEL DISTANCE 2. FIRE EXTINGUISHER, EXIT SIGN, & FIRE ALARM DEVICE LOCATIONS ARE SHOWN FOR
TOTAL AREA IN SCOPE: APPROX. 30,978 SF WATER CLOSETS 11 12 REFERENCE, INTENDED EGRESS, & DESIGN INTENT. FINAL DEVICE LOCATIONS ARE
00 00 ASSEMBLY - UNCONCENTRATED SUBJECT TO REVIEW WITH FIRE MARSHAL/INSPECTORS. REVIEW WITH INSPECTORS
COMMON PATH OF TRAVEL
00 (15NSF/OCCUPANT):
WORK CAFE 727 NET SF 49 OCC
TENANT OCCUPANCY: 415 OCCUPANTS
IBC TABLE 1004.1.1
LAVATORIES 7 8 DURING ROUGH-IN TO CONFIRM LOCATIONS & QUANTITIES.
NOT FOR
LOAD CAPACITY DRINKING FOUNTAINS 4 4
OCCUPANCY CLASSIFICATION LEGEND
ASSEMBLY - CONCENTRATED
CHAIRS ONLY NOT FIXTED:
EGRESS WIDTH REQUIREMENTS:
OTHER EGRESS COMPONENTS
IBC TABLE 1005.1 EXCEPTION 2 IPC SECTION 410.1
CONSTRUCTION
TRAINING 90 OCC REQUIRED (.15 IN/OCCUPANT): 62.25 INCHES
PROVIDED AT EXIT STAIR DOORS: 68 INCHES
ASSEMBLY (NON-CONCENTRATED) - 1 PERSON/15SF ACCESSORY (300 GSF/OCCUPANT): EXIT STAIR WIDTH
STORAGES, SERVER, ELEC & JAN 997 GROSS SF 4 OCC REQUIRED (.2 IN/OCCUPANT) 83 INCHES Project Name
PROVIDED AT EXIT STAIRS: 92 INCHES
ASSEMBLY (CONCENTRATED - CHAIRS ONLY NOT FIXED) - 1 PERSON/7SF BUSINESS (100 GSF/OCCUPANT):
GENERAL OFFICE 27,148 GROSS SF 272 OCC MINIMUM WIDTH OF EGRESS CORRIDOR REQUIRED: 44 INCHES
UCB BIOSCIENCES
IBC 1018.2
BUSINESS - 1 PERSON/100 SF TOTAL TENANT OCCUPANT 415 OCC
MINIMUM WIDTH OF EGRESS CORRIDOR PROVIDED: 60 INCHES Project Number
ACCESSORY (STORAGE / MECHANICAL) - 1 PERSON/300 SF
MINIMUM NUMBER OF EXITS REQUIRED: 2 EXITS
IBC TABLE 1021.1
090.0338.000
Description
NUMBER OF EXITS PROVIDED: 2 EXITS
EGRESS & OCCUPANCY PLAN -
MAXIMUM LENGTH OF EGRESS TRAVEL: 300 FEET
IBC TABLE 1016.1 LEVEL 03
MAXIMUM COMMON PATH OF TRAVEL: 100 FEET
IBC 1014.3 EXCEPTION 1
Scale
MAXIMUM DEAD END CORRIDOR: 50 FEET
IBC 1018.4 EXCEPTION 2 As indicated
ACCESS CONTROLLED HARDWARE (ELECTROMAGNETIC LOCK - FAIL OPEN) MEETING ALL
REQUIREMENTS OF IBC 1008.1.4.4.
6/19/2020 5:17:51 PM
EGRESS & OCCUPANCY CALCULATION - LEVEL 03 G2.03
02 SCALE: 1 1/2" = 1'-0"
© 2020 GenslerGENERAL NOTES
02 41 19.D02 02 41 19.D02
UCB
1. ISOLATE NON-LOAD-BEARING FRAMING FROM STRUCTURAL
EXISTING SLAB TO REMAIN
09 29 00.F02
EXISTING SLAB TO REMAIN
09 29 00.F02
ELEMENTS TO PREVENT TRANSFER OF DEFLECTION LOADS
TO PARTITIONS. STOP STUDS 3/4" BELOW CEILING RUNNERS
(TOP TRACKS). DO NOT ATTACH STUDS TO TOP TRACK. DO
BIOSCIENCES
PRE-FORMED MINERAL WOOL WALL PRE-FORMED MINERAL WOOL WALL
NOT ATTACH GYPSUM BOARD TO DEFLECTION TRACK. STOP 4000 Paramount Pkwy
PLUG PLUG
09 22 16.A03 09 22 16.A03 GYPSUM BOARD 3/4" BELOW DECK. UL DETAIL REQUIREMENTS Suite 200 & 300
TAKE PRECEDENCE OVER DIMENSIONS LISTED HERE.
FLAT STRAP & BACKING PLATE FLAT STRAP & BACKING PLATE Morrisville, NC 27560
09 29 00.G00 09 29 00.G00 2. COORDINATE PARTITION LAYOUT WITH SPECIFIED FINISHES
CONTINUOUS ACOUS SEALANT CONTINUOUS ACOUS SEALANT AND PANELING TO ENSURE REQUIRED CLEARANCES ARE
PROVIDED.
09 22 16.A11
09 22 16.A11 3. FOLLOW STUD MANUFACTURER'S GUIDELINES FOR FRAMING
SLIP-TYPE HEAD JOINT
SLIP-TYPE HEAD JOINT LIMITING LENGTHS. REFER TO PROJECT MANUAL FOR
09 29 00.F00 FRAMING DEFLECTION CRITERIA.
09 29 00.F00
SOUND ATTENUATION BLANKET
SOUND ATTENUATION BLANKET PARTITIONS WITH ASSIGNED STC RATINGS SHALL:
SCHEDULED CEILING, REFER SCHEDULED CEILING, REFER 1. BE CONSTRUCTED TO ACHIEVE INDICATED STC RATINGS PER 613 Hillsborough St. Tel 919.239.7828
TO REFLECTED CEILING PLAN MAJOR TESTING AGENCY METHODS & DETAILS. Raleigh, NC 27603 Fax 919.239.7829
TO REFLECTED CEILING PLAN
2. HAVE STAGGERED GYPSUM BOARD JOINTS, WITHIN EACH United States
09 29 00.A01 09 22 16.A00 LAYER & BETWEEN MULTIPLE LAYERS.
GYP BD 5/8" METAL STUD
3. HAVE ACOUSTICALLY SEALED JOINTS AT FLOORS, SIDES, &
09 29 00.A01 TOPS.
09 22 16.A00
GYP BD 5/8"
METAL STUD
VARIES 4. HAVE ELECTRICAL & LOW VOLTAGE BOXES ON OPPOSITE
SIDES OF THE PARTITION BE STAGGERED, SEPARATED BY AT
REFER TO PLAN(S) LEAST ONE STUD, AND FULLY SEALED WITH
SOUNDLINERS/PUTTY PADS.
5. HAVE ACOUSTICAL SEALANT AT ALL PENETRATIONS; MINIMIZE
SIZE OF PENETRATION OPENINGS IN GYPSUM BOARD.
05 D-T01 01 A-T01 1.
FIRE-RATED PARTITIONS SHALL COMPLY WITH THE...
CONSTRUCT TO ENSURE CONTINUITY OF REQUIRED
SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" FIRE-RATING(S). MORE STRINGENT FIRE RATINGS TAKE
PRIORITY OVER LESS STRINGENT CONSTRUCTION.
FIRE-RATED CONSTRUCTION SHALL BE COMPLETE PRIOR TO
INTERSECTING NON-RATED PARTITIONS.
2. GAGES, SIZES, FASTENERS, & QUANTITATIVE NOTES &
SPECIFICATIONS ARE MINIMUMS FOR FIRE RATING
REQUIREMENTS. UL DETAIL DEFINES MINIMUM
REQUIREMENTS FOR GAGES, SIZES, & FASTENERS. IF
02 41 19.D02 CONFLICTS EXIST BETWEEN ANY SPECIFICATIONS/DRAWINGS,
02 41 19.D02
EXISTING SLAB TO REMAIN THE MORE STRINGENT NOTE/SPEC TAKES PRECEDENCE.
EXISTING SLAB TO REMAIN
09 22 16.A03
09 22 16.A03 3. HORIZONTAL JOINTS BETWEEN VERTICALLY ORIENTED
FLAT STRAP & BACKING PLATE
FLAT STRAP & BACKING PLATE GYPSUM BOARD SHEETS SHALL BE BACKED WITH
09 22 16.A11 09 22 16.A11 HORIZONTAL STUDS SPANNING BETWEEN VERTICAL STUDS.
SLIP-TYPE HEAD JOINT SLIP-TYPE HEAD JOINT MATCH STUDS IN GAGE, SIZE, & FASTENING.
4. NON-METALLIC ELECTRICAL BOXES SHALL NOT BE INSTALLED
6"
09 29 00.F00 ON OPPOSITE SIDES OF FIRE-RATED PARTITIONS, UNLESS
09 29 00.F00
SOUND ATTENUATION BLANKET CLASSIFIED FOR FIRE-RESISTANCE AS DEFINED BY UL
SOUND ATTENUATION BLANKET SECTION "OUTLET BOXES AND FITTINGS CLASSIFIED FOR FIRE
24" MIN
02 41 19.D01 RESISTANCE."
BOTH SIDES 09 22 16.A00
6"
EXISTING WALL TO REMAIN
METAL STUD 5. METALLIC ELECTRICAL BOXES SHALL NOT EXCEED 16 SQ IN
WITHIN THE WALL FACE, NOR EXCEED 100 SQ IN AGGREGATE
SCHEDULED CEILING, REFER 09 29 00.F00 SURFACE AREA PER 100 SQ FT OF WALL SURFACE. MAINTAIN
TO REFLECTED CEILING PLAN 3 1/2" SOUND ATTENUATION BLANKET ON BOTH SIDES MAXIMUM OF 1/8" CLEARANCE BETWEEN BOXES AND GYPSUM
09 29 00.A01 (AT FOCUS & HUDDLE, COORD. W/ AOR) BOARD.
GYP BD 5/8" 6. PENETRATIONS SHALL BE SEALED PER APPROPRIATE UL
SCHEDULED CEILING, REFER TESTED METHODS, AS DEFINED BY UL SECTION
09 22 16.A00 TO REFLECTED CEILING PLAN "THROUGH-PENETRATION FIRESTOP SYSTEMS."
METAL STUD 09 29 00.A01 7. ALL SCREWS SHALL MEET REQUIREMENTS OF ASTM C1002 OR
VARIES GYP BD 5/8" ASTM C954.
REFER TO PLAN(S)
06 D-T03 02 A-T03 Date Description
SCALE: 3" = 1'-0" SCALE: 3" = 1'-0"
2 2020-04-24 DD PRICING
3 2020-06-19 DD REVISED PRICING
VARIES
REFER TO PLAN(S)
02 41 19.D01 09 29 00.A01
EXISTING WALL TO REMAIN GYP BD 5/8"
09 29 00.A01 09 29 00.F00
GYP BD 5/8" SOUND ATTENUATION BLANKET
09 29 00.F00 09 22 16.A00
SOUND ATTENUATION BLANKET METAL STUD
09 22 16.A00 09 22 16.A01
METAL STUD METAL RUNNER TRACK
09 22 16.A01 09 29 00.G00
METAL RUNNER TRACK CONTINUOUS ACOUS SEALANT
09 29 00.G00 02 41 19.D02
CONTINUOUS ACOUS SEALANT EXISTING SLAB TO REMAIN
02 41 19.D02
EXISTING SLAB TO REMAIN
07 D-B01 03 A-B01
SCALE: 3" = 1'-0" SCALE: 3" = 1'-0"
BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt
Seal / Signature
09 29 00.A01
GYP BD 5/8" 09 29 00.A01
GYP BD 5/8"
NOT FOR
09 22 16.A00 09 22 16.A00
METAL STUD METAL STUD
09 29 00.F00
CONSTRUCTION
02 41 19.D01
SOUND ATTENUATION BLANKET
EXISTING WALL OR COLUMN TO REMAIN
Project Name
UCB BIOSCIENCES
VARIES
Project Number
090.0338.000
Description
PARTITION FRAMING (IN) DETAILS PARTITION FRAMING (IN) DETAILS
TYPE ATTEN FIRE TEST STC TYPE ATTEN FIRE TEST STC PARTITION TYPE DETAILS
MARK DEPTH SPACING TOP BOT THK RTG ASSEMBLY RTG COMMENTS MARK DEPTH SPACING TOP BOT THK RTG ASSEMBLY RTG COMMENTS
D2C 2 1/2" 16" O.C. D-T01 D B01 A3A 3 5/8" 16" O.C. A-T01 A-B01 3-1/2"
D3A 3 5/8" 16" O.C. D-T01 D B01 A3B 3 5/8" 16" O.C. A-T03 A-B01 3-1/2"
D3B 3 5/8" 16" O.C. D-T02 D B01 A3C 3 5/8" 16" O.C. A-B01 3-1/2"
D3C 3 5/8" 16" O.C. D-T02 D B01 A6C 6" 16" O.C. A-T03 A-B01 3-1/2" Scale
3" = 1'-0"
6/19/2020 5:18:01 PM
08 D SERIES PARTITION TYPES
SCALE: 3" = 1'-0" 04 A SERIES PARTITION TYPES
SCALE: 3" = 1'-0"
G5.01
© 2020 GenslerDOOR SCHEDULE - LEVEL 02
GENERAL NOTES
ASSEMBLY LEAF FRAME DETAILS
ASSEMBL
Y RATING
UCB
LOCATION
ROOM
DIMENSIONS
FIRE HARDWARE
1. ALL LOCKSETS SHALL BE OPERABLE FROM THE INSIDE
ALONG THE PATH OF EGRESS WITHOUT THE USE OF A
KEY OR SPECIAL KNOWLEDGE. SPECIAL LOCKING
BIOSCIENCES
NUMBER TYPE ROOM NAME NUMBER WIDTH HEIGHT THICKNESS MATERIAL FINISH MATERIAL FINISH HEAD JAMB SILL RATING SET REMARKS DEVICES SHALL BE OF AN APPROVED TYPE. ALL 4000 Paramount Pkwy
LEVERSETS SHALL HAVE ACCESSIBLE LEVER STYLE.
2000A A 3' - 0" 8' - 0" 0' - 1 3/4" SC ST HM PT 01/G6.02 01/G6.02 21 ACCESS CONTROL Suite 200 & 300
2000B A 3' - 0" 8' - 0" 0' - 1 3/4" SC ST HM PT 01/G6.02 01/G6.02 21 ACCESS CONTROL 2. REQUIRED INTERIOR DOOR OPENING FORCE SHALL Morrisville, NC 27560
2001A G RECEPTION 2001 6' - 0" 9' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 02/G6.02 02/G6.02 41 ACCESS CONTROL NOT EXCEED 5 LB.
2001B F RECEPTION 2001 3' - 0" 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 03/G6.02 03/G6.02 D5 3. DOORS TO MECHANICAL, ELECTRICAL, & MACHINES
2003 F LG CONF 2003 3' - 0" 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 03/G6.02 03/G6.02 D1 ROOMS SHALL HAVE KNURLED TEXTURE ON INSIDE
FACE OF LEVER.
2004 F SM CONF 2004 3' - 0" 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 03/G6.02 03/G6.02 D1
2011 F PIONEER COLLAB 2010 2' - 11" 8' - 0" 4. ELECTRIFIED NON-MAGNETIC LOCKSETS SPECIFIED AS
FAIL-SECURE SHALL HAVE A MANUAL KEY OVERRIDE
2012 A WAR ROOM 2012 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1 MATCHING BASE BUILDING KEYWAY.
2012A A STORAGE 2012A 3' - 0" 8' - 0" 0' - 1 3/4" SC ST HM PT 01/G6.02 01/G6.02 02
5. ALL HARDWARE TO BE HEAVY DUTY FULL MORTISE...
2014 A SERVER 2014 3' - 0" 8' - 0" 0' - 1 3/4" SC ST HM PT 01/G6.02 01/G6.02 21 ACCESS CONTROL. PROVIDE 18"X18" LOUVER - COORD. 613 Hillsborough St. Tel 919.239.7828
6. ALL WOOD DOORS SHALL BE SOLID CORE. Raleigh, NC 27603 Fax 919.239.7829
W/ MECH
7. COORDINATE KEYING WITH OWNER/TENANT & United States
2015 A RESTROOM 2015 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 04 LANDLORD, IF APPLICABLE. LOCKSETS SHALL HAVE
2016 A STORAGE 2016 3' - 0" 8' - 0" 0' - 1 3/4" SC 04 INTERCHANGEABLE CORES.
2017 A RESTROOM 2017 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 04 8. UNDERCUT INTERIOR DOORS BY 1/4" TYPICALLY;
COORDINATE WITH MECHANICAL DRAWINGS FOR
2018 A WELLNESS 2018 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 04 LOCATIONS FOR HIGHER UNDERCUTS, IF ANY.
2019 A WELLNESS 2019 3' - 0" 8' - 0" 0' - 1 3/4" SC 9. REINFORCED HOLLOW METAL FRAMES ARE REQUIRED
2020 A STORAGE 2020 3' - 0" 8' - 0" 0' - 1 3/4" SC FOR HEAVY DUTY HINGES.
10. ALL BUTT HINGED LEAFS OVER 3'-0" WIDE TO HAVE 5" X
2021A F PIONEER COLLAB 2010 3' - 0" 8' - 0" 4 1/2" HINGES.
2021AA B 4' - 2 1/4" 8' - 0" 0' - 1 3/4" SC ST 10 DOOR AND HARDWARE BY OPERABLE PARTITION MFR. 11. EXTERIOR DOOR HINGES SHALL BE NON-FERROUS AND
2021B F PIONEER COLLAB 2010 3' - 0" 8' - 0" HAVE NON-REMOVABLE PINS.
2022 A FURN STORAGE 2022 3' - 0" 8' - 0" 0' - 1 3/4" SC 12. COORDINATE SECURITY REQUIREMENTS &
PROGRAMMING WITH OWNER/TENANT, SECURITY
2023 F PHONE 2023 2' - 8" 8' - 0" DESIGNER, & SECURITY VENDOR PRIOR TO
2024 F PHONE 2024 2' - 9" 8' - 0" FABRICATION OF DOORS & FRAMES. PROVIDE
CONDUIT & OTHER ROUGH-IN FOR ELECTRIFIED
2030A F LIBRARY VESTIBULE 2030 3' - 1" 8' - 0" HARDWARE.
2030B A LIBRARY VESTIBULE 2030 3' - 0" 8' - 0" 0' - 1 3/4" SC
13. CONFIRM LOCKSET TYPE AND MANUFACTURER WITH
2031 F LIBRARY 2040 3' - 0" 8' - 0" LANDLORD (IF APPLICABLE) TO COORDINATE WITH
2032 F LIBRARY 2040 3' - 0" 8' - 0" BUILDING STANDARDS.
14. DOOR HARDWARE FINISH SHALL BE BLACK, UNLESS
2041 F BUBBLE 2041 3' - 1" 8' - 0"
NOTED OTHERWISE.
2043 F BUBBLE 2043 3' - 1" 8' - 0" 15. WHERE EXISTING DOOR, FRAMES, AND/OR HARDWARE
2045 F BUBBLE 2045 3' - 3 9/16" 8' - 0" ARE TO BE RE-USED, VERIFY EXISTING ELEMENTS ARE
IN WORKING ORDER & COMPATIBLE WITH SECURITY &
2047 F BUBBLE 2047 3' - 1" 8' - 0" FUNCTIONAL REQUIREMENTS. CLEAN EXISTING
2051 F BUBBLE 2051 3' - 1" 8' - 0" DOORS, FRAMES, & HARDWARE.
2052 F LIBRARY 2060 3' - 0" 8' - 0"
2053 F BUBBLE 2053 3' - 2 5/32" 8' - 0" 16. ALL EXISTING-TO-REMAIN DOORS SHALL RECEIVE NEW
HARDWARE. EXISTING DOORS SHALL BE PATCHED &
2054 F LIBRARY 2060 2' - 11 7/8" 8' - 0" REPAIRED TO RECEIVE NEW HARDWARE.
2055 F COLLAB 2050 3' - 3 7/32" 8' - 0"
2061 A LIBRARY 2060 2' - 11" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1
2063 A LIBRARY 2060 2' - 9 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1
25/32"
2065 A LIBRARY 2060 2' - 10 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1
13/32"
2067 A LIBRARY 2060 2' - 11" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1
2069 A LIBRARY 2060 2' - 11" 8' - 0" 0' - 1 3/4" SC D1
S201 A 3' - 0" 8' - 0" 0' - 1 3/4" SC
S202 A 3' - 0" 8' - 0" 0' - 1 3/4" SC ABBREVIATION
DOOR SCHEDULE - LEVEL 03
AL ALUMINUM
ASSEMBL GL GLAZING
ASSEMBLY LEAF FRAME DETAILS Y RATING HM HOLLOW METAL
LOCATION DIMENSIONS MFR MANUFACTURER
ROOM FIRE HARDWARE PT PAINTED Date Description
NUMBER TYPE ROOM NAME NUMBER WIDTH HEIGHT THICKNESS MATERIAL FINISH MATERIAL FINISH HEAD JAMB SILL RATING SET REMARKS SC SOLID CORE
2 2020-04-24 DD PRICING
3000A G WORK CAFE 3001 6' - 0" 9' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 02/G6.02 41 ACCESS CONTROL ST STAINED VENEER
3 2020-06-19 DD REVISED PRICING
3000B G ELEVATOR LOBBY 3000 6' - 0" 9' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 02/G6.02 41 ACCESS CONTROL
3003 A STORAGE 3003 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 21
3004 A SERVER 3004 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 21 ACCESS CONTROL
3005 A IT WORKROOM 3005 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 21 ACCESS CONTROL
3006 F HALO CONFERENCE 3006 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3007 A STORAGE 3007 3' - 0" 8' - 0" 0' - 1 3/4" SC
3008 F PHONE 3008 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3009 F PHONE 3009 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3011 F TREADMILL 3011 3' - 0" 8' - 0" D1
3012 F BUBBLE 3012 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3013 F BUBBLE 3013 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3014 F HUDDLE 3014 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3021 F TREADMILL 3021 3' - 1 1/2" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3022 F BUBBLE 3022 2' - 10 1/2" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3023 F BUBBLE 3023 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3024 F HUDDLE 3024 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3025 F MD CONF 3025 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3026 F MD CONF 3026 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3031 F PHONE 3031 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3032 F BUBBLE 3032 3' - 0 3/4" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3033 F BUBBLE 3033 3' - 0 5/8" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3034 F HUDDLE 3034 3' - 0 1/2" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3035 F SM CONF 3035 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3036 F SM CONF 3036 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3041 F PHONE 3041 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3042 F BUBBLE 3042 3' - 0 3/8" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3043 F BUBBLE 3043 3' - 0 1/4" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3044 F HUDDLE 3044 3' - 0 1/8" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3048 A STORAGE 3048 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 04
BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt
3051 F CREATIVE WORK 3050 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3052 E BUBBLE 3052 3' - 2" 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 04/G6.02 D3
3053 E BUBBLE 3053 3' - 0 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 04/G6.02 D3 Seal / Signature
23/32"
3054 E BUBBLE 3054 2' - 11 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 04/G6.02 D3
7/16"
3061
3062
F
F
TREADMILL
OPEN OFFICE
3061
3060
3' - 0"
3' - 0"
8' - 0"
8' - 0"
ST
ST
AL
AL
BY MFR
BY MFR
03/G6.02
03/G6.02
03/G6.02
03/G6.02
D1
D1
NOT FOR
3063
3064
F
F
OPEN OFFICE
OPEN OFFICE
3060
3060
3' - 0"
3' - 0"
8' - 0"
8' - 0"
ST
ST
AL
AL
BY MFR
BY MFR
03/G6.02
03/G6.02
03/G6.02
03/G6.02
D1
D1
CONSTRUCTION
3066 F PHONE 3066 3' - 0" 8' - 0" D1
3067 F PHONE 3067 3' - 0" 8' - 0" D1
Project Name
3071 F TREADMILL 3071 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3072 F OPEN OFFICE 3070 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 UCB BIOSCIENCES
3073 F OPEN OFFICE 3070 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3074 F OPEN OFFICE 3070 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3075 F MD CONF 3075 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 D1 Project Number
3076 F LG CONF 3076 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 D1
3081 F PHONE 3081 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
090.0338.000
3082 F BUBBLE 3082 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 Description
3083 F BUBBLE 3083 3' - 0" 8' - 0" D1 DOOR ELEVATIONS AND DOOR
3084 F HUDDLE 3084 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
SCHEDULE
3085 F SM CONF 3085 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 D1
3091 F PHONE 3091 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3092 F BUBBLE 3092 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
Scale
3093 F BUBBLE 3093 3' - 0" 8' - 0" D1
3094 F HUDDLE 3094 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1
3096 F HR SUITE 3096 3' - 0" 8' - 0" D1
3097A F HUDDLE 3097 3' - 0" 8' - 0" D1
6/19/2020 5:18:04 PM
3097B A HUDDLE 3097 3' - 0" 8' - 0" 0' - 1 3/4" SC
S301 A STAIR S301 3' - 0" 8' - 0" 0' - 1 3/4" SC EXIST HM PT 45 MIN EXISTING DOOR/FRAME, ACCESS CONTROL, COORD. W/
LANDLORD SECURITY G6.01
S302 A STAIR S302 3' - 0" 8' - 0" 0' - 1 3/4" SC EXIST HM PT 45 MIN EXISTING DOOR/FRAME, ACCESS CONTROL, COORD. W/
LANDLORD SECURITY
© 2020 Gensler41 - SINGLE LEAF - GLASS, MAGNETIC 01 - SINGLE LEAF - PASSAGE FUNCTION UCB
2 SECURING DEVICES 36" BAR PULL X HANGING DEVICES BUTT HINGES, BALL BEARING
SCHEDULED PARTITION
1 SECURING DEVICES
1 CLOSERS DEVICES
1 MISC DEVICES
ELECTRO-MAGNETIC LOCK
OVERHEAD CONCEALED CLOSER WITH INTEGRAL PIVOT AND MATCHING BOTTOM PIVOT
REQUEST TO EXIT, MOTION SENSOR
1
1
1
SECURING DEVICES
CLOSERS DEVICES
STOPS AND HOLDERS
MORTISE LOCKSET, PASSAGE FUNCTION
SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE)
FLOOR STOP
BIOSCIENCES
1 MISC DEVICES PUSH TO EXIT BUTTON - MISC DEVICES SILENCERS GREY 4000 Paramount Pkwy
NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO ALLOW FREE Suite 200 & 300
6" TYP, UNO
JAMB: ADJACENT WALL,
EGRESS AT ALL TIMES.
WHERE APPLICABLE Morrisville, NC 27560
02 - SINGLE LEAF - STORAGE FUNCTION
1/2" TYP SEALANT AT JAMB, BOTH SIDES
41 - DOUBLE LEAF - GLASS, MAGNETIC X HANGING DEVICES BUTT HINGES, BALL BEARING
HEAD: CEILING, WHERE APPLICABLE 1 SECURING DEVICES MORTISE LOCKSET, STORAGE FUNCTION
2"
4 SECURING DEVICES 36" BAR PULL 1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE)
HM FRAME 2 SECURING DEVICES ELECTRO-MAGNETIC LOCK 1 STOPS AND HOLDERS FLOOR STOP
2 CLOSERS DEVICES OVERHEAD CONCEALED CLOSER WITH INTEGRAL PIVOT AND MATCHING BOTTOM PIVOT - MISC DEVICES SILENCERS GREY
5/8"
DOOR 1 MISC DEVICES REQUEST TO EXIT, MOTION SENSOR
1 MISC DEVICES PUSH TO EXIT BUTTON 03 - SINGLE LEAF - OFFICE/ENTRY FUNCTION
NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO ALLOW FREE
X HANGING DEVICES BUTT HINGES, BALL BEARING 613 Hillsborough St. Tel 919.239.7828
EGRESS AT ALL TIMES.
1 SECURING DEVICES MORTISE LOCKSET, OFFICE/ENTRY FUNCTION Raleigh, NC 27603 Fax 919.239.7829
1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE) United States
1 STOPS AND HOLDERS FLOOR STOP
- MISC DEVICES SILENCERS GREY
04 - SINGLE LEAF - PRIVACY FUNCTION
X HANGING DEVICES BUTT HINGES, BALL BEARING
D1 - DEMOUNTABLE SINGLE LEAF - PASSAGE FUNCTION 1 SECURING DEVICES MORTISE LOCKSET, PRIVACY FUNCTION WITH OCCUPANCY INDICATOR
01 DOOR DETAIL - HM HEAD/JAMB ALL HARDWARE PROVIDED BY DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE 1
1
CLOSERS DEVICES
STOPS AND HOLDERS
SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE)
FLOOR STOP
SCALE: 3" = 1'-0"
X HANGING DEVICES - MISC DEVICES SILENCERS GREY
2 SECURING DEVICES 36" BAR PULL
1 CLOSERS DEVICES CLOSER
1 STOPS AND HOLDERS FLOOR STOP & ANGLE STOP, BY DOOR HARDWARE VENDOR
- MISC DEVICES SILENCERS BLACK
SCHEDULED PARTITION
D2 - DEMOUNTABLE SINGLE LEAF - PASSAGE FUNCTION
HEAD: METAL STUD BOX HEADER ALL HARDWARE PROVIDED BY THE DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE
10 - DOUBLE LEAF - CLOSET
X HANGING DEVICES
JAMB: ADJACENT WALL, X HANGING DEVICES BUTT HINGES, BALL BEARING
6" TYP, UNO
1 SECURING DEVICES PANIC BAR, 36" BAR PULL
WHERE APPLICABLE 1 CLOSERS DEVICES CLOSER 2 SECURING DEVICES DUMMY LEVERS (OUTSIDE CLOSET)
1 STOPS AND HOLDERS FLOOR STOP & ANGLE STOP, BY DOOR HARDWARE VENDOR 2 SECURING DEVICES ROLLER LATCH WITH INTEGRAL ANGLE STOP
SCHEDULED PARTITION 1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE)
- MISC DEVICES SILENCERS BLACK
2 STOPS AND HOLDERS OVERHEAD STOP
HEAD: CEILING, WHERE APPLICABLE
1 1/2"
D3 - DEMOUNTABLE SLIDING SINGLE LEAF - PASSAGE FUNCTION 11 - DOUBLE LEAF - PASSAGE
ALUMINUM FRAME ALL HARDWARE PROVIDED BY DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE
X HANGING DEVICES BUTT HINGES, BALL BEARING
X HANGING DEVICES 2 SECURING DEVICES MORTISE LOCKSET, PASSAGE FUNCTION (ACTIVE LEAF)
2 SECURING DEVICES 36" BAR PULL 1 SECURING DEVICES TOP & BOTTOM MANUAL FLUSH BOLTS (INACTIVE LEAF)
DOOR OR GLASS 1 STOPS AND HOLDERS INTEGRAL SLIDER TRACK 2 SECURING DEVICES ROLLER LATCH WITH INTEGRAL ANGLE STOP
- MISC DEVICES BRUSH GASKETS BLACK 1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (ACTIVE LEAF, NON PUBLIC SIDE)
2 STOPS AND HOLDERS FLOOR STOP
D4 - DEMOUNTABLE SINGLE LEAF - PASSAGE FUNCTION 1 MISC DEVICES DUSTPROOF STRIKE
ALL HARDWARE PROVIDED BY DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE
12 - DOUBLE LEAF - EXIT DEVICE - BLANK / ACTIVE FUNCTION
X HANGING DEVICES
2 SECURING DEVICES 36" BAR PULL X HANGING DEVICES BUTT HINGES, BALL BEARING
1 CLOSERS DEVICES CLOSER 2 SECURING DEVICES RIM EXIT DEVICE WITH CONCEALED VERTICAL TOP & BOTTOM RODS, BLANK/ACTIVE FUNCTION
1 STOPS AND HOLDERS ANGLE STOP, BY DOOR HARDWARE VENDOR 2 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE)
- MISC DEVICES SILENCERS BLACK 2 STOPS AND HOLDERS FLOOR STOP
02 DOOR/GLASS DETAIL - ALUM HEAD/JAMB 2 MISC DEVICES DUSTPROOF STRIKE
SCALE: 3" = 1'-0" D5 - DEMOUNTABLE SINGLE LEAF - MAGNETIC
ALL HARDWARE PROVIDED BY DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE
X HANGING DEVICES
2 SECURING DEVICES 36" BAR PULL
1 CLOSERS DEVICES CLOSER
SCHEDULED PARTITION 1 STOPS AND HOLDERS ANGLE STOP, BY DOOR HARDWARE VENDOR
- MISC DEVICES SILENCERS BLACK 21 - SINGLE LEAF - ACCESS CONTROL, ELECTRONIC
1 SECURING DEVICES ELECTRO-MAGNETIC LOCK, BY SECURITY VENDOR X HANGING DEVICES BUTT HINGES, BALL BEARING
1 MISC DEVICES REQUEST TO EXIT, MOTION SENSOR 1 HANGING DEVICES ELECTRIC THROUGH-WIRE HINGE
1 MISC DEVICES PUSH TO EXIT BUTTON 1 SECURING DEVICES MORTISE LOCKSET, ELECTRONIC Date Description
CEILING, WHERE APPLICABLE NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO ALLOW FREE 1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE)
EGRESS AT ALL TIMES. COORDINATE WITH SECURITY VENDOR. 1 STOPS AND HOLDERS FLOOR STOP 2 2020-04-24 DD PRICING
- MISC DEVICES SILENCERS GREY 3 2020-06-19 DD REVISED PRICING
METAL STUD BOX HEADER NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO ALLOW FREE
EGRESS AT ALL TIMES.
DEMOUNTABLE FRAME AND DOOR
EQ EQ 31 - DOUBLE LEAF - ACCESS CONTROL, MAGNETIC
X HANGING DEVICES BUTT HINGES, BALL BEARING
1 SECURING DEVICES MORTISE LOCKSET, DUMMY (ACTIVE LEAF)
1 SECURING DEVICES MANUAL FLUSH BOLT (INACTIVE LEAF)
03 DEMOUNTABLE HEAD - JAMB SIMILAR 1
2
SECURIING DEVICES
CLOSERS DEVICES
ELECTRO-MAGNETIC LOCK (ACTIVE LEAF)
CONCEALED OVERHEAD CLOSER
SCALE: 3" = 1'-0"
1 MISC DEVICES REQUEST TO EXIT, MOTION SENSOR
1 MISC DEVICE PUSH TO EXIT BUTTON
NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. MAGLOCK MUST BE FAIL-SAFE.
32 - DOUBLE LEAF - ACCESS CONTROL, MAGNETIC
X HANGING DEVICES BUTT HINGES, BALL BEARING
4 SECURING DEVICES 36" BAR PULLS
SCHEDULED PARTITION 2 SECURIING DEVICES ELECTRO-MAGNETIC LOCK
2 CLOSERS DEVICES OVERHEAD CONCEALED CLOSER
METAL STUD BOX HEADER 1 MISC DEVICES REQUEST TO EXIT, MOTION SENSOR
1 MISC DEVICE PUSH TO EXIT BUTTON
NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. MAGLOCK MUST BE FAIL-SAFE.
SCHEDULED CEILING
DEMOUNTABLE FRAME 33 - DOUBLE LEAF - ACCESS CONTROL, ELECTRONIC
X HANGING DEVICES BUTT HINGES, BALL BEARING
SLIDING DOOR 1 HANGING DEVICES ELECTRIC THROUGH-WIRE HINGE
2 SECURING DEVICES MORTISE LOCKSET, ELECTRONIC (ACTIVE LEAF)
BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt
1 SECURING DEVICES MANUAL FLUSH BOLT (INACTIVE LEAF)
OFFICE OR OPEN OFFICE 1 SECURING DEVICES DUSTPROOF STRIKE
CONFERENCE OR CORRIDOR 2 CLOSERS DEVICES CONCEALED OVERHEAD CLOSER
- MISC DEVICES SILENCERS GREY Seal / Signature
ROOM
2 MISC DEVICES MAGNETIC HOLD OPEN DEVICE
NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO BE HELD OPEN
DURING BUSINESS HOURS, CLOSED AFTER HOURS. AFTER HOURS, DOOR TO BE OPENED BY CARD READER.
NOT FOR
04 DOOR DETAIL - DEMOUNTABLE SLIDING HEAD
SCALE: 3" = 1'-0" CONSTRUCTION
AS SCHEDULED AS SCHEDULED
AS SCHEDULED AS SCHEDULED
AS SCHEDULED Project Name
UCB BIOSCIENCES
AS AS AS Project Number
SCHEDULED SCHEDULED SCHEDULED
DOOR FRAME
090.0338.000
AS SCHEDULED
AS SCHEDULED
AS SCHEDULED
AS SCHEDULED
AS SCHEDULED
AS SCHEDULED
DOOR LEAF AS Description
SCHEDULED
DOOR, FRAME AND HARDWARE
2' - 10" AFF MIN
2' - 10" AFF MIN
2' - 10" AFF MIN
SCHEDULES
LOUVER AS
SCHEDULED
Scale
As indicated
TYPE G TYPE F TYPE E TYPE B TYPE A
DOUBLE FLUSH GLASS DOOR SINGLE FLUSH GLASS DOOR SINGLE FLUSH SLIDING GLASS DOOR DOUBLE FLUSH DOOR SINGLE FLUSH DOOR
6/19/2020 5:18:15 PM
W/ RAILS & STILES W/ RAILS & STILES AS SCHEDULED AS SCHEDULED
DOOR TYPES
G6.02
05 SCALE: 3/8" = 1'-0"
© 2020 GenslerYou can also read