For lasting comfort in every one of your customer's homes - Comfort for your home

Page created by Cecil Becker
 
CONTINUE READING
For lasting comfort in every one of your customer's homes - Comfort for your home
Heating   Hot water   Renewables

For lasting comfort
in every one of your
customer‘s homes

                               Comfort for your home
For lasting comfort in every one of your customer's homes - Comfort for your home
About Vaillant.....................................................................................................................................................3
    Setting the standards since 1874............................................................................................4
    Why choose a Vaillant product?...............................................................................................5
    Introducing Green iQ......................................................................................................................6
    ecoTEC & ecoFIT combi boilers................................................................................................. 7
    ecoTEC & ecoFIT system boilers............................................................................................... 17
    ecoTEC & ecoFIT open vent boilers........................................................................................ 25
    Technical data................................................................................................................................... 29
    Flue lengths....................................................................................................................................... 40
    Terminal clearances....................................................................................................................... 41
    Flue solutions.................................................................................................................................... 42
1
For lasting comfort in every one of your customer's homes - Comfort for your home
Controls............................................................................................................................................... 45
                      MyVAILLANT Pro.............................................................................................................................. 54
                      Water filters....................................................................................................................................... 56
                      Domestic hot water cylinders................................................................................................... 59
                      Training ............................................................................................................................................... 63
                      Service and spares support....................................................................................................... 64
                      Guarantees......................................................................................................................................... 65
                      Order numbers................................................................................................................................. 66

Please note the information contained in this guide is for the use of competent and qualified heating engineers in the UK. We always recommend attending a training course
provided by Vaillant to ensure complete knowledge of the appliance and/or accessories you are installing. The Vaillant Group does not warrant the accuracy or completeness
of any of the information provided in this brochure. Should you require any clarification or further information, please speak with your ASM or call our technical helpline. The
Vaillant Group does not accept liability or responsibility resulting from the installer’s failure to comply with the guides or otherwise. For more detailed information, please
refer to the installation manual for each product you are using.
                                                                                                                                                                                    2
For lasting comfort in every one of your customer's homes - Comfort for your home
About Vaillant

    The Vaillant Group
    Vaillant is a brand within the Vaillant Group, a family-owned business that was founded by Johann Vaillant in his workshop in
    Remscheid, Germany in 1874.

    In 1894, Johann patented a new closed-system gas-fired bathroom boiler. Johann’s technical innovations continued and in 1924,
    he launched the world’s first central heating boiler. Since these revolutionary inventions, the Vaillant brand has become synonymous
    with innovative heating solutions and continues to drive the evolution of heating technologies to this day.

    The Vaillant Group is still family owned, and the family’s consideration for safeguarding the environment for future generations runs
    through everything that Vaillant does. Vaillant is passionate about developing technologies that use the quality and efficiency of
    German engineering to create heating solutions that reduce carbon emissions and energy use to help to reduce our impact on
    the planet.

    As the premium brand for sustainable and responsible heating and hot water solutions, it is Vaillant’s mission to create a better
    climate, inside each home and the world around it.

    There are now over 13,000 employees across 10 sites around the world who share this vision.

3
For lasting comfort in every one of your customer's homes - Comfort for your home
Setting the standards since 1874
Manufacturing at its finest
At Vaillant, we think ahead. By choosing our heating appliances, you choose the pioneering excellence of German design and UK
manufacturing expertise that create reliable products specially designed for application in all markets.

As well as designing products to be as efficient as possible, we constantly review and update our manufacturing processes and
environments.

Our UK factory continues to receive awards year after year in many categories. In addition to the many manufacturing awards we have
received, we are especially proud to have been awarded the RoSPA Gold Award for world-class health and safety management systems
for three consecutive years. We also have a gold Investors in People Award.

Vaillant has very high standards in manufacturing to ensure we make outstanding products. Our products meet ISO 9001, 18001,
14000 and many are Quiet MarkTM approved, which means that they use innovative and efficient technology that guarantees reduced
noise levels.

                                                                                                                                      4
For lasting comfort in every one of your customer's homes - Comfort for your home
Why choose a Vaillant product?			                                   We always recommend our appliances are fitted with a Vaillant
    Vaillant manufactures one of the largest ranges of boilers in       control. Vaillant has a wide range of controls, and each uses
    the world and has its own renewables portfolio. From simple         eBUS, our proprietary technology that ensures each element
    boilers for small dwellings to complex hybrid systems for           of a Vaillant system can communicate to ensure it is always
    commercial premises, Vaillant has a solution for every building’s   working with ultimate efficiency.
    requirements.
                                                                        All our controls come with load compensation as standard.
    Our core business is our award winning domestic boiler range.       Every Vaillant heating appliance can be matched with the
    Vaillant produces wall-hung boilers with outputs from 12kW          perfect control to ensure compliance with Boiler Plus legislation.
    to 64kW and has open vent, system and combination models.
    With a wide range of flue options and a vast catalogue of           Vaillant’s controls range from simple analogue controls to smart
    accessories, including our own range of cylinders, we are           app-controlled models that can be integrated with smart home
    confident we have a solution for every installation. We can even    systems and alert you to faults.
    offer a unique combination storage boiler that has a 20 litres
    per minute flow rate.                                               Our new range of senso controls have been designed to be
                                                                        incredibly easy to use and, with a stylish contemporary design,
    Vaillant also manufactures boilers for commercial installations.    will look beautiful wherever they’re sited.
    Vaillant’s commercial portfolio consists of large output wall-
    hung and floor-standing condensing boilers with compatible
    cascade rigs and accessories to cater for simple and large scale
    projects.

5
For lasting comfort in every one of your customer's homes - Comfort for your home
Introducing Green iQ

A smart badge: Green iQ
The Vaillant brand demonstrates the philosophy of the Vaillant Group with the development of our flagship Green iQ range of
boilers and heat pumps. We are proud that these products are incredibly efficient, have a low carbon footprint, are more than 85%
recyclable and are engineered to be networked for the future.

The products in the Green iQ range combine our complete range of smart technologies and features to provide great performance.

The ecoTEC exclusive with Green iQ range of boilers intelligently manages energy consumption and output. This ensures the
components of each boiler only work as hard as necessary to ensure optimum performance. Components will therefore last longer
and be more reliable, reducing overall maintenance costs.

The ecoTEC exclusive with Green iQ range consists of two large output combi boilers with a host of features including extra
condense technology. The system boiler in the range includes an integrated diverter valve, a first for Vaillant UK.

                                                                                                                                    6
For lasting comfort in every one of your customer's homes - Comfort for your home
ecoTEC exclusive with Green iQ
    Combi boilers

    Overview
    The ecoTEC exclusive is our first ever boiler range with the Green iQ technology. Combining our complete range of smart
    technologies and features, you can be sure you’re fitting the very best when you fit an ecoTEC exclusive combi.

    As well as providing great performance, the ecoTEC exclusive intelligently manages consumption and output to keep all its
    components running at peak performance, for longer, providing a low maintenance solution that you can rely on.

    The combi range features 35kW and 43kW models, which can deliver much higher than average central heating outputs and hot
    water flow rates, making the ecoTEC exclusive a must have for larger properties. Additionally, the design of the ecoTEC exclusive
    combination boilers allows domestic hot water to be pre-heated using what would be wasted flue gas energy (full heat condense).
    This makes the boiler best in class for efficiency and Boiler Plus compliant out of the box.

    All models in the ecoTEC exclusive range have patented high quality stainless steel heat exchangers that provide superior heat
    transfer and highly efficient performance.

7
For lasting comfort in every one of your customer's homes - Comfort for your home
Key features and benefits                                       • 10-year guarantee available
 • Boiler Plus compliant out of the box                            A free five year guarantee comes as standard, rising to
                                                                   seven years out of the box when registered on Advance. A
   Full heat condense
                                                                   10-year guarantee is available when boilers are installed
 • Green iQ mode                                                   with a Boiler Protection Kit and registered on Advance
   Outstanding eco-credentials which optimise running            • Easy installation and maintenance
   cycles, resulting in even lower gas consumption
                                                                   Accessible layout allows all components to be replaced
 • Highly recyclable                                               from the boiler front. Removable side panels for even
   ecoTEC exclusive is 85% recyclable at the end of its life       more access

 • Premium quality components                                    • Step by step full text installation wizard
   Includes brass diverter valve, ensuring highest reliability     For quicker, ‘first time right’ set-up and installation
   and performance                                               • High power, 43kW output model available
 • Wide modulation range of up to 1:10                             Delivers Vaillant’s highest ever flow rate
   Adapts perfectly to all systems in every situation,           • All-gas system
   ensuring lowest fuel bills for your customers
                                                                   As a self-adaptive system, it automatically adjusts to all
 • Extra condense stainless steel heat exchanger                   types of gas including LPG for off-gas areas
   Takes overall combi boiler efficiency to the next level,      • Compatible with Vaillant’s range of intelligent controls
   and almost eliminates plume in DHW mode
                                                                   Delivers an easy to use and energy efficient system,
 • Quiet Mark accreditation                                        saving money on energy bills
   One of the quietest boilers on the market, designed for a     • Flame lift detection system
   peaceful home
                                                                   For enabling more efficient and quieter combustion
                                                                 • Self diagnostic combustion intelligence
                                                                   Includes flame lift detection for more efficient and
                                                                   quieter combustion

Dimensions:                                                                      Clearances:

                440mm

                                                  720mm
     B

                                                                                  Note: A 500mm front
                                                                                  clearance is recommended
                                                                                  to allow easy access during
     Installation depth       Dimension B                                         inspection and maintenance
     ecoTEC exclusive 835     406mm

     ecoTEC exclusive 843     474mm

                                                                                                                                8
For lasting comfort in every one of your customer's homes - Comfort for your home
ecoTEC plus
    Combi boilers

    Overview
    The ecoTEC plus range of combination boilers is extremely reliable. All models have the quality of components and manufacturing
    that Vaillant is known for, providing outstanding performance and build quality.

    With continuous modulation and real combustion control by a multi-sensor system, Vaillant’s ecoTEC plus boilers achieve high
    efficiency at the lowest emissions.

    The ecoTEC plus is available in a range of power outputs to meet the heating requirements of varying house sizes. Each one is ultra-
    quiet, a feature recognised by the Noise Abatement Society, which has awarded many of the ecoTEC plus range the Quiet Mark for
    its innovative design, specifically created to ensure a peaceful home for your customers.

9
Key features and benefits                                        • Dedicated models available for LPG
 • Boiler Plus compliant with Vaillant controls                     A perfect solution for off-gas areas
   Install with sensoHOME, sensoCOMFORT, vSMART, or VRC           • Compatible with Vaillant’s range of intelligent controls
   700 for a smart weather compensated system                       Delivers an easy to use and energy efficient system, saving
 • Premium quality components                                       money on energy bills
   Includes brass diverter valve, ensuring highest reliability    • Electronic gas and air modulation system
   and performance                                                  Allows precise self setting gas combustion to improve
 • Wide modulation range of up to 1:6                               performance and lower emissions
   Adapts perfectly to all systems in every situation, ensuring   • Flame lift detection system
   lowest fuel bills for your customers                             Enables more efficient and quieter combustion
 • Patented stainless steel heat exchanger                        • Push fit flue system with industry leading flue lengths
   Provides superior heat transfer and highly                       80/125 flue adaptor and system for even longer lengths
   efficient performance                                            and installation flexibility
 • 10-year guarantee available                                    • Large backlit plain text display
   A free five year guarantee comes as standard, rising to          Delivers clear visibility in poor light conditions and easy
   seven years out of the box when registered on Advance. A         reading of current boiler operation
   10-year guarantee is available when boilers are installed
   with a Boiler Protection Kit and registered on Advance         • Features Vaillant’s exclusive AquaComfort system
 • Easy installation and maintenance                                Provides quick delivery of hot water at a constant
                                                                    temperature, which reduces unnecessary water wastage
   Accessible layout allows all components to be replaced
   from the boiler front. Removable side panels for even          • Integrated filling loop
   more access                                                      Makes installation even quicker
 • Step by step full text installation wizard                     • Built-in two-stage frost protection
   For error free, quick and simple set-up and installation         Ensures optimal performance all year round
 • 38kW output model available
   Delivers a range of flow rates to suit all properties

Dimensions:                                                                     Clearances:

                440mm

                                                    720mm
     B

                                                                                Note: A 500mm front
                                                                                clearance is recommended
                                                                                to allow easy access during
              Installation depth   Dimension B
                                                                                inspection and maintenance
              ecoTEC plus 825
                                   338mm
              ecoTEC plus 832
              ecoTEC plus 835      372mm

              ecoTEC plus 838      406mm

                                                                                                                                  10
ecoTEC plus
     Storage combi boilers

     Overview
     The ecoTEC plus storage combi is a 38kW high efficiency storage combination boiler which has been designed especially for larger
     homes that have a higher hot water demand, but not enough to warrant the installation of a cylinder.

     The ecoTEC plus storage combi features an innovative integrated hot water storage device at the back of the boiler. This special
     feature means the product is capable of delivering up to 20 litres of hot water per minute.

     The ecoTEC plus storage combi has a stainless steel heat exchanger alongside the premium components you expect from a Vaillant
     appliance.

11
Key features and benefits                                        • Innovative 38kW solution for large homes
 • Boiler Plus compliant with Vaillant controls                     Integrated hot water storage delivers best in class flow
                                                                    rates to suit a range of properties
   Install with sensoHOME, sensoCOMFORT, vSMART, or VRC
   700 for a smart weather compensated system                     • Compatible with Vaillant’s range of intelligent controls
 • Premium quality components                                       Delivers an easy to use and energy efficient system, saving
                                                                    money on energy bills
   Includes brass diverter valve, ensuring highest reliability
   and performance                                                • Electronic gas and air modulation system
 • Wide modulation range of up to 1:6                               Allows precise self setting gas combustion to improve
                                                                    performance and lower emissions
   Adapts perfectly to all systems in every situation, ensuring
   lowest fuel bills for your customers                           • Flame lift detection system
 • Patented stainless steel heat exchanger                          Enables more efficient and quieter combustion
   Provides superior heat transfer and highly efficient           • Push fit flue system with industry leading flue lengths
   performance                                                      80/125 flue adaptor and system for even longer flue
 • 10-year guarantee available                                      lengths and installation flexibility
   A free five year guarantee comes as standard, rising to        • Large backlit plain text display
   seven years out of the box when registered on Advance. A         Delivers clear visibility in poor light conditions and easy
   10-year guarantee is available when boilers are installed        reading of current boiler operation
   with a Boiler Protection Kit and registered on Advance
                                                                  • Integrated filling loop
 • Easy installation and maintenance
                                                                    Makes installation even quicker
   Accessible layout allows all main boiler components to be
   replaced from the boiler front                                 • Built-in two-stage frost protection
 • Step-by-step full text installation wizard                       Ensures optimal performance all year round
   For error free, quick and simple set-up and installation

Dimensions:                                                                      Clearances:

              440mm

                                                    720mm
    600mm

                                                                                  Note: A 500mm front
                                                                                  clearance is recommended
                                                                                  to allow easy access during
                                                                                  inspection and maintenance

                                                                                                                                  12
ecoTEC pro
     Combi boilers

     Overview
     The ecoTEC pro range of combination boilers combines the built-in quality, reliability, and performance you’d expect from Vaillant,
     with a simple design and approach.

     The range features 24, 28, and 30kW models, making this boiler perfect for homes with smaller heating and hot water
     requirements.

     With a small footprint and compact dimensions, the ecoTEC pro combination boilers offer versatile siting options. They’re also really
     easy to install and service, with a push-fit flue system and removable side panels to make life that much easier.

     The ecoTEC pro has an LPG version of this boiler, so it’s perfect for off-gas areas. It’s also compatible with our aroTHERM heat
     pumps, offering even more choice for off-grid properties.

13
Key features and benefits                                    • Dedicated model available for LPG
 • Boiler Plus compliant with Vaillant controls                 A great solution for off-gas areas
   Install with sensoHOME, sensoCOMFORT, vSMART, or VRC       • Compatible with Vaillant’s range of intelligent controls
   700 for a smart weather compensated system                   Delivers an easy to use and energy efficient system,
 • Quality components                                           saving money on energy bills
   Quality and reliabilty you would expect from Vaillant      • Electronic gas and air modulation system
 • Wide modulation range of up to 1:5                           Allows precise self setting gas combustion to improve
                                                                performance and lower emissions
   Adapts perfectly to most systems in domestic
   applications, resulting in lower fuel bills for your       • Flame lift detection system
   customers                                                    Enables more efficient and quieter combustion
 • Patented stainless steel heat exchanger                    • Push fit flue system with industry leading flue lengths
   Provides superior heat transfer and highly                   80/125 flue adaptor and sytem for even greater flue
   efficient performance                                        lengths
 • Seven year guarantee available                             • Plain text display
   A free two year guarantee comes as standard, rising to       High quality text for clear visibility and understanding of
   seven years out of the box when registered on Advance        current boiler operation
 • Easy installation and maintenance                          • Features Vaillant’s exclusive AquaComfort system
   Accessible layout allows all components to be replaced       Provides quick delivery of hot water at a constant
   from the boiler front. Removable side panels for even        temperature, preventing unnecessary water wastage
   more access
                                                              • ErP A rated boiler range
 • Step by step installation wizard
                                                                Delivers highest efficiency and lowest running costs
   For error free, quick and simple set-up and installation
                                                              • Built-in two-stage frost protection
 • 30kW output model available
                                                                Ensures optimal performance all year round
   Delivers a range of flow rates to suit all properties

Dimensions:                                                                  Clearances:

                   440

                                                   720
   338

                                                                              Note: A 500mm front
                                                                              clearance is recommended
                                                                              to allow easy access during
                                                                              inspection and maintenance

                                                                                                                              14
ecoFIT pure
     Combi boilers

     Overview
     Ultra-quiet operation, a small footprint and total flexibility of siting (with top and rear flue options) mean that the ecoFIT pure range
     fits in with your customers’ needs. It’s the perfect solution for fitting inside a standard kitchen cupboard unit.

     The automatic purging assistant and high specification, automotive grade, aluminium heat exchanger makes for a lightweight
     installation.

     With high quality, highly efficient components, complete availability of spare parts and an accessible layout, the ecoFIT pure is easy
     to maintain and service.

15
Key features and benefits                                       • Easy installation and maintenance
 • Compact, cupboard fit solution                                  Accessible layout allows all components to be replaced
                                                                   from the boiler front. Removable side panels for even
   A smaller footprint and cupboard fit dimensions 		              more access
   offers flexibility of siting
                                                                 • 35kW output model available
 • Four-sided cooling and water agitation of the heat
                                                                   Delivers a range of flow rates to suit all properties
   exchanger
                                                                 • Compatible with Vaillant’s range of intelligent controls
   Reduces the stress on the heat exchanger for longer life
   reliability and reduced maintenance costs                       Delivers an easy to use and energy efficient system, saving
                                                                   money on energy bills
 • Boiler Plus compliant with Vaillant controls
                                                                 • Pneumatic gas and air modulation system
   Install with VRT 350 or VRT 50 + timeSWITCH 150 for a
   load compensated system                                         For precise self setting gas combustion to improve
                                                                   performance and lower emissions
 • Premium quality components
                                                                 • Top and rear flue options
   For great reliability and performance
                                                                   Flue options and cupboard fit dimensions offer flexibility
 • Wide modulation range of up to 1:5                              of siting
   Adapts perfectly to most systems in domestic
                                                                 • Push fit flue system with industry leading flue lengths
   applications, resulting in lower fuel bills for your
   customers                                                       80/125 vertical flue lengths of up to 25m for greater
                                                                   installation flexibility
 • H
    igh-specification aluminium heat exchanger
                                                                 • Bright clear LED display
   Designed for longer life, easier maintenance, and smaller
   energy bills                                                    Delivers clear visibility in poor light conditions and easy
                                                                   reading of current boiler operation
 • Seven year guarantee available
                                                                 • ErP A rated boiler range
   A free two year guarantee comes as standard, rising to
   seven years out of the box when registered on Advance.          Delivers highest efficiency and lowest running costs
   It’s also eligible for a 10-year guarantee when fitted with   • Integrated filling loop
   our Boiler Protection Kit
                                                                   Makes installation even quicker

Dimensions:                                                                      Clearances:

                   390

                                                   700
   295

                                                                                 Note: A 500mm front
                                                                                 clearance is recommended
                                                                                 to allow easy access during
                                                                                 inspection and maintenance

                                                                                                                                 16
ecoTEC exclusive with Green iQ
     System boilers

     Overview
     The ecoTEC exclusive is our first ever boiler with Green iQ technology. Combining our complete range of smart technologies and
     features, you can be sure you’re fitting the very best when you fit new the new 27kW ecoTEC exclusive with Green iQ system boiler.

     As well as providing great performance, the ecoTEC exclusive intelligently manages consumption and output to keep all its
     components running at peak performance, for longer, providing a low maintenance solution that you can rely on.

     The ecoTEC exclusive system boiler includes an integrated diverter valve for the first time in UK Vaillant history.

17
Key features and benefits                                         • Easy installation and maintenance
 • Green iQ Mode                                                     Accessible layout allows all components to be replaced
                                                                     from the boiler front. Removable side panels for even
   Outstanding eco-credentials which optimise running
                                                                     more access
   cycles, resulting in even lower gas consumption
                                                                   • Step-by-step full text installation wizard
 • Highly recyclable
                                                                     For error free, quick and simple set-up and installation
   ecoTEC exclusive is 85% recyclable at the end of its life
                                                                   • All-gas system
 • Premium quality components
                                                                     Always reaches optimal combustion with lowest emissions.
   Ensures highest reliability and performance                       As a self-adaptive system, it automatically adjusts to all
                                                                     types of gas
 • Wide modulation range of up to 1:10
   Adapts perfectly to all systems in every situation, resulting   • Compatible with Vaillant’s range of intelligent controls
   in lower fuel bills for your customers                            Delivers an easy to use and energy efficient system, saving
                                                                     money on energy bills
 • Patented stainless steel heat exchanger
   Provides superior heat transfer and highly efficient            • Integrated three-way valve
   performance                                                       Four-pipe system with load compensation in DHW and CH
                                                                     modes. No more complex wiring systems, junction boxes
 • 10-year guarantee available                                       or external zone valves
   A free five year guarantee comes as standard, rising to
   seven years out of the box when registered on Advance. A        • Push fit flue system with industry leading flue lengths
   10-year guarantee is available when boilers are installed         80/125 vertical flue lengths for even greater flue lengths
   with a Boiler Protection Kit and registered on Advance

Dimensions:                                                                       Clearances:

                 440mm

                                                   720mm
  338mm

                                                                                   Note: A 500mm front
                                                                                   clearance is recommended
                                                                                   to allow easy access during
                                                                                   inspection and maintenance

                                                                                                                                   18
ecoTEC plus
     System boilers

     Overview
     The ecoTEC plus range of boilers is extremely reliable. All models have the quality of components and manufacturing that Vaillant is
     known for, providing outstanding performance and build quality.

     With continuous modulation and real combustion control by a multi-sensor system, Vaillant’s ecoTEC plus boilers achieve high
     efficiency at the lowest emissions.

     The ecoTEC plus system boiler is available in a range of power outputs to meet the heating requirements of varying house sizes.
     With outputs of 12, 15, 18, 24 ,30 and 37kWs, there’s a perfect size for the requirements of most domestic buildings.

     Whichever output you choose, you can be assured it is ultra-quiet, a feature recognised by the Noise Abatement Society, which has
     awarded the ecoTEC plus range the Quiet Mark for its innovative design, specifically created to ensure a peaceful home for your
     customers.

19
Key features and benefits                                     • Dedicated models available for LPG
 • Boiler Plus compliant with time and temperature 		            A great solution for off-gas areas
   controls                                                    • Electronic gas and air modulation system
   Install with VRT 15, timeSWITCH 160 and VR 66 		              Allows precise self setting gas combustion to improve
   wiring centre for the easiest way to meet Boiler Plus         performance and lower emissions
 • Premium quality components                                  • Flame lift detection system
   For highest reliability and performance                       Enables more efficient and quieter combustion
 • Wide modulation range of up to 1:6                          • Push fit flue system with industry leading flue lengths
   Adapts perfectly to all systems in every situation,           80/125 vertical flue lengths of up to 41m for greater
   resulting in lower fuel bills for your customers              installation flexibility
 • Patented stainless steel heat exchanger                     • Large backlit plain text display
   Provides superior heat transfer and highly                    Delivers clear visibility in poor light conditions and easy
   efficient performance                                         reading of current boiler operation
 • 10-year guarantee available                                 • Compatible with heat pump hybrid system
   A free five year guarantee comes as standard, rising to       Can be fitted with an aroTHERM heat pump to create a
   seven years out of the box when registered on Advance. A      hybrid system
   10-year guarantee is available when boilers are installed
   with a Boiler Protection Kit and registered on Advance      • Precise German engineering and design
 • Easy installation and maintenance                             Quality manufacturing from award winning factory
                                                                 in Derbyshire
   Accessible layout allows all components to be replaced
   from the boiler front. Removable side panels for even       • R
                                                                  ecognisable Vaillant fault codes
   more access                                                   Making it easy to diagnose faults
 • Step by step full text installation wizard
   For error free, quick and simple set-up and installation

Dimensions:                                                                   Clearances:

                440mm

                                                  720mm
     B

                                                                               Note: A 500mm front
                                                                               clearance is recommended
                                                                               to allow easy access during
     Installation depth       Dimension B                                      inspection and maintenance

     ecoTEC plus 612
     ecoTEC plus 615
                              338mm
     ecoTEC plus 618
     ecoTEC plus 624
     ecoTEC plus 630          372mm

     ecoTEC plus 637          406mm

                                                                                                                               20
ecoTEC plus
     Large output system boilers

     Overview
     The ecoTEC plus 48 and 64kW boilers are compact in size and extremely lightweight. The front and side panels can be removed,
     allowing for much easier access in tight and restrictive spaces.

     The internal ducted rain collector prevents rain ingress from the flue system depositing in the boiler casing, and the new gunmetal
     air separation device prevents unwanted vented emissions within the case, both of which help to protect the electronics inside the
     boiler. ecoTEC plus 48 and 64kW can be converted to LPG to cater for projects that are unable to use a natural gas supply. These boilers
     can be cascaded for projects that require outputs above 70kW.

21
Key features and benefits                                              • Electronic gas and air modulation system
 • Compact dimensions                                                     Allows for precise self setting gas combustion to improve
                                                                          performance and lower emissions
   For easy siting in tight spaces
                                                                        • A range of push fit flue systems available
 • ErP A+ rated
                                                                          80/125 vertical, horizontal and facade flue accessories for
   When installed with a class VI control
                                                                          greater installation flexibility
 • Low NOx burner system
                                                                        • Large backlit plain text display
   Levels as low as 29mg/kWh to minimise environmental
                                                                          Delivers clear visibility in poor light conditions and easy
   impact
                                                                          reading of current boiler operation
 • Premium quality components
                                                                        • Built-in two-stage frost protection
   Ensures highest reliability and performance
                                                                          Ensures optimal performance all year round
 • Wide modulation range of up to 1:5
                                                                        • Compatible with heat pump hybrid system
   Adapts perfectly to all systems in every situation, resulting
                                                                          Can be fitted with an aroTHERM heat pump to create a
   in lower fuel bills for your customers
                                                                          hybrid system
 • Patented stainless steel heat exchanger
                                                                        • Recognisable Vaillant fault codes
   Provides superior heat transfer and highly efficient
                                                                          For easy diagnosis
   performance
                                                                        • Out of the box guarantees
 • Easy installation and maintenance
                                                                          Five-year guarantee as standard, for added peace of mind
   Accessible layout allows all components to be replaced
   from the boiler front. Removable side panels for even                • Ability to cascade
   more access                                                            For flexible siting and increased outputs of up to 256kW.
 • Step by step full text installation wizard                             Cascaded larger output boilers can operate up to 3bar
    For error free, quick and simple set-up and installation
 • Compatible with LPG
    A great solution for off-gas areas

Dimensions:                                                                             Clearances:

                  440mm
                                                                                                  350mm, 80/125 flue

                                                   720mm
     B

                                                                                         Note: A 500mm front
                                                                                         clearance is recommended
                                                                                         to allow easy access during
         Installation depth     Dimension B
                                                                                         inspection and maintenance
         ecoTEC plus 48         405mm

         ecoTEC plus 64         473mm

Note: Our larger output boilers must be fitted with Vaillant’s proprietary low loss header (WH40/2 article number 0020248932)
designed to fit directly under the boiler
                                                                                                                                        22
ecoFIT pure
     System boilers

     Overview
     ecoFIT pure system boilers offer great features and a wide range of outputs, with 12, 15, 18, 25 and 30kW outputs. They’re all ultra-
     quiet in operation, have a small footprint and flexible siting options (including a choice of top or rear flues).

     The automatic purging assistance and high specification, aluminium heat exchanger make for a lightweight installation.

     With high quality, highly efficient components, complete availability of spare parts and an accessible layout, the ecoFIT pure easy to
     maintain and service.

23
Key features and benefits                                    • 	Top and rear flue options
                                                                  A smaller footprint and cupboard fit dimensions offer
 • Premium quality components
                                                                flexibility of siting
   Ensuring highest reliability and performance
                                                              • Push fit flue system with industry leading flue lengths
 • Boiler Plus compliant with time and temperature 		           80/125 vertical flue lengths of up to 25m for greater
   controls                                                     installation flexibility
   Install with VRT 15, timeSWITCH 160 and VR 66 		           • Bright clear LED display
   wiring centre for the easiest way to meet Boiler Plus
                                                                Delivers clear visibility in poor light conditions and easy
 • Wide modulation range of up to 1:5                           reading of current boiler operation
   Adapts perfectly to all systems in every situation,        • ErP A rated boiler
   resulting in lower fuel bills for your customers             Delivers highest efficiency and lowest running costs
 • 	Patented high-specification aluminium heat exchanger     • Built-in two-stage frost protection
   Designed for longer life, easier maintenance and             Ensures optimal performance all year round
   smaller energy bills
                                                              • Patented four-sided cooling and water agitation of the
 • Out of the box guarantees				                                heat exchanger
   Two year free guarantee can be extended to seven
                                                                Reduces stress on the heat exchanger for longer life
   years when installs are registered on Advance. It’s also
                                                                reliability and reduced maintenance costs
   eligible for a 10-year guarantee when fitted with our
   Boiler Protection Kit.                                     • Precise German engineering and design
                                                                Quality manufacturing from award winning factory
 • Easy installation and maintenance
                                                                in Derbyshire
   Accessible layout allows all components to be replaced
   from the boiler front. Removable side panels for even      • Recognisable Vaillant fault codes
   more access                                                  For easy fault diagnosis

 • Pneumatic gas and air modulation system
   Allows precise self setting gas combustion to improve
   performance and lower emissions

Dimensions:                                                                   Clearances:

                   390

                                                  700
   295

                                                                              Note: A 600mm front
                                                                              clearance is recommended
                                                                              to allow easy access during
                                                                              inspection and maintenance

                                                                                                                              24
ecoTEC plus
     Open vent boilers

     Overview
     The ecoTEC plus range of open vent boilers is extremely reliable. All models have the quality of components and manufacturing that
     Vaillant is known for, providing outstanding performance and build quality.

     With continuous modulation and real combustion control by a multi-sensor system, Vaillant’s ecoTEC plus boilers achieve high
     efficiency at the lowest emissions. These boilers have an aluminium heat exchanger with wide waterways: an ideal choice for older
     properties.

     They’re available with outputs of 12, 15, 18 ,24, 30 and 35kW, so there’s an ecoTEC plus open vent boiler that can meet the heating
     requirements of varying house sizes.

     Each one is ultra-quiet, a feature recognised by the Noise Abatement Society, which has awarded the ecoTEC plus range the Quiet
     Mark for its innovative design, specifically created to ensure a peaceful home for your customers.

25
Key features and benefits                                            • Dedicated model available for LPG
                                                                        Great solution for off-gas areas
 • Wide modulation range of up to 1:5
   Adapts perfectly to all systems in every situation,                • Electronic gas and air modulation system
   resulting in lower fuel bills for your customers                     Allows for precise self setting gas combustion to
                                                                        improve performance and lower emissions
 • Boiler Plus compliant with time and temperature
   controls                                                           • 	Top and rear flue options
                                                                          Flue options and cupboard fit dimensions offer flexibility
   Install with VRT 15, timeSWITCH 160 and VR 66
                                                                        of siting
   wiring centre for the easiest way to meet Boiler Plus
                                                                      • Push fit flue system with industry leading flue lengths
 • 	High-specification aluminium heat exchanger
                                                                        80/125 vertical flue lengths of up to 25m for greater
   Designed for longer life, easier maintenance and
                                                                        installation flexibility
   smaller energy bills
                                                                      • Bright clear LED display
 • 10 year guarantee available
   A free five year guarantee comes as standard, rising to              Delivers clear visibility in poor light conditions and easy
   seven years out of the box when registered on Advance.               reading of current boiler operation
   A 10 year guarantee is available when boilers are installed
   with a Boiler Protection Kit and registered on Advance             • ErP A rated boiler
                                                                        Delivers highest efficiency and lowest running costs
 • Easy installation and maintenance
                                                                      • Compatible with heat pump hybrid system
   Accessible layout allows all components to be replaced               Can be fitted with an aroTHERM heat pump to create a
   from the boiler front. Removable side panels for even                hybrid system
   more access
 • Compact, cupboard fit solution
   Smaller boiler footprint offers flexibility of siting, including
   a cupboard fit

Dimensions:                                                                           Clearances:

                 375mm

                                                     602mm
  295mm

                                                                                       Note: A 600mm front
                                                                                       clearance is recommended
                                                                                       to allow easy access during
                                                                                       inspection and maintenance

                                                                                                                                       26
ecoFIT pure
     Open vent boilers

     Overview
     The ecoFIT pure range of open vent boilers has a wide range of outputs to choose from, with 12, 15, 18, 25, 30 and 35kW models
     available. With ultra-quiet operation, a small footprint and flexible siting options (including a choice of top or rear flues), the ecoFIT
     pure range has a model to fit your customers’ needs.

     The automatic purging assistance and high specification, aluminium heat exchanger make for a lightweight installation.

     High quality and high efficiency, together with the complete availability of spare parts and the easy accessibility of the unit layout
     means the ecoFIT pure is easy to maintain too.

27
Key features and benefits                                   • Pneumatic gas and air modulation system
 • Premium quality components                                  Allows precise self setting gas combustion to improve
                                                               performance and lower emissions
   For great reliability and performance
                                                             • 	Top and rear flue options
 • Wide modulation range of up to 1:5
                                                                 Flexible flue options to suit various properties
   Adapts perfectly to all systems in every situation,
   ensuring lowest fuel bills for your customers             • Push fit flue system with industry leading flue lengths
                                                               80/125 vertical flue lengths of up to 25m for greater
 • Boiler Plus compliant with time and temperature 		          installation flexibility
   controls
                                                             • Bright clear LED display
   Install with VRT 15, timeSWITCH 160 and VR 66 		            Delivers clear visibility in poor light conditions and easy
   wiring centre for the easiest way to meet Boiler Plus       reading of current boiler operation
 • 	High-specification aluminium heat exchanger             • ErP A rated boiler
   Designed for longer life, easier maintenance, and lower     Delivers highest efficiency and lowest running costs
   energy bills
                                                             • Built-in two-stage frost protection
 • Seven year guarantee available				                          Ensures optimal performance all year round
   A free two year guarantee comes as standard and is
   extended to seven years when registered on Advance        • Patented four-sided cooling and water agitation of the
                                                               heat exchanger
 • Easy installation and maintenance
                                                               Reduces stress on the heat exchanger to increase
   Accessible layout allows all components to be replaced      longevity and reliability while reducing maintenance costs
   from the boiler front. Removable side panels for even
   more access                                               • Precise German engineering and design
                                                               Quality manufacturing from Vaillant’s award winning
 • Compact, cupboard fit solution                              factory in Derbyshire
   Flexible siting options due to small footprint and
   cupboard fit dimensions                                   • Recognisable Vaillant fault codes
                                                               For easy fault diagnosis

Dimensions:                                                                  Clearances:

                   375

                                                 602
   295

                                                                             Note: A 600mm front
                                                                             clearance is recommended
                                                                             to allow easy access during
                                                                             inspection and maintenance

                                                                                                                            28
Technical data
                                                                                 ecoTEC                       ecoTEC
      Technical data                                     Unit of measure
                                                                              exclusive 835                exclusive 843
      General
      Boiler type                                                                                 Combi
      Signature model output                                    kW                  35                             43
      Article number                                                           0010017064                   0010017065
      Gas Council number                                                        47-044-66                       47-044-67
      Boiler dimensions (HxWxD)                                mm             720 x 440 x 406              720 x 440 x 474
      Performance
      NOx (En 15502-2-1)                                     mg/kWh                 35                             36
      ErP efficiency (heating / DHW)                     A+++ - D / A+ - F                        A /A
      ErP efficiency                                            %                                  94
      ErP decibel rating (sound power)                         dBa                  43                             51
      Heating
      Nominal heat output range at 50/30˚C
                                                                kW               3.9 - 26.4                     4.8 - 36.0
      (condensing mode)
      Nominal heat output range at 80/60˚C
                                                                kW               3.4 - 24.6                     4.3 - 33.4
      (non condensing mode)
      Maximum flow temperature                                  ˚C                                 85
      Flow temperature range                                    ˚C                               30 - 80
      Flow temperature factory setting                          ˚C                                  75
      Approximate condensate volume at 50/30˚C               Litres/hr             2.48                           3.37
      Modulation (max/min)                                     1:X                 1:10.4                         1:10.1
      Domestic hot water
      Maximum heat output for water generation                  kW                 35.3                           43.4
      Lowest water pressure to operate boiler                  Bar                                 0.35
      Lowest water flow for operation                          l/min                                1.5
      Lowest water pressure for maximum flow rate              Bar                                 0.8
      Domestic hot water flow rate (at ∆t = 35K)               l/min               14.5                            17.8
      Domestic hot water flow rate (at ∆t = 45K)*              l/min                11.2                          13.8
      Hot water output temperature range                        ˚C                               35 - 65
      Mechanical
      Expansion vessel size                                   Litres                                10
      Gas inlet connection (pipe size)                         mm                   15                             20
      Heating flow and return connections (pipe size)          mm                                   22
      Hot and cold water connections (pipe size)               mm                                   15
      Heat exchanger material                           Stainless/Aluminium                   Stainless steel
      Boiler lift weight (dry boiler)                           kg                 47.5                           55.0
      Maximum horizontal flue length 60/100                     m                                  5.5
      Rear flue options                                       Yes/No                                No
      Permissible flue classifications                                                        C13, C33, C53
      Minimum clearances
      Side left and right                                      mm                                   5
      Top                                                      mm                                  165
      Top (if using rear flue)                                 mm                                    -
      Below                                                    mm                   180                           300
      Front                                                    mm                                  500

     *Achieved via fitment of a flow restrictor

29
ecoTEC
                                             Unit of       ecoTEC          ecoTEC                                ecoTEC         ecoTEC
 Technical data                                                                                  plus
                                             measure      plus 825        plus 832                              plus 835       plus 838
                                                                                               832 LPG
 General
 Boiler type                                                                                  Combi
 Signature model output                          kW           25             32               32                     35             38
 Article number                                           0010021823     0010021824       0010021825            0010021822     0010021826
 Gas Council number                                       47-044-83      47-044-84        47-044-85             47-044-82      47-044-86
                                                                                                                 720 x 440      720 x 440
 Boiler dimensions (HxWxD)                      mm                      720 x 440 x 338
                                                                                                                   x 372          x 406
 Performance
 NOx (En 15502-2-1)                           mg/kWh          32              35                  55                 29            34
                                             A+++ - D /
 ErP efficiency (heating / DHW)                                                                   A /A
                                               A+ - F
 ErP efficiency                                  %                                                 94
 ErP decibel rating (sound power)               dBa                           47                                     46            45
 Heating
 Nominal heat output range at 50/30˚C
                                                 kW        4.1 - 20.8      5.7 - 26.4          6.5 - 25.5         6.4 - 32.8    7.1 - 30.9
 (condensing mode)
 Nominal heat output range at 80/60˚C
                                                 kW        3.8 - 19.3      5.2 - 24.4          6.0 - 24.4         5.8 - 30.4    6.5 - 28.6
 (non condensing mode)
 Maximum flow temperature                        ˚C                                                85
 Flow temperature range                          ˚C                                              30 - 80
 Flow temperature
                                                 ˚C                                                 75
 factory setting
 Approximate condensate
                                              Litres/hr       2.0                       2.5                          3.1           2.9
 volume at 50/30˚C
 Modulation (max/min)                           1:X          1:6.7            1:6.1              1:5.3              1:6.0         1:6.0
 Domestic hot water
 Maximum heat output for water
                                                 kW          25.4                       31.8                        35.0          38.7
 generation
 Lowest water pressure to operate boiler        Bar                                                0.35
 Lowest water flow for operation               l/min                                                2
 Lowest water pressure for maximum
                                                Bar                                                0.8
 flow rate
 Domestic hot water flow rate
                                               l/min         10.5                       13.0                        14.3           15.9
 (at ∆t = 35K)
 Domestic hot water flow rate
                                               l/min          8.8                       10.9                         11.9          13.2
 (at ∆t = 42K)*
 Hot water output temperature range              ˚C                                              35 - 65
 Mechanical
 Expansion vessel size                         Litres                                               10
 Gas inlet connection (pipe size)               mm                                                  15
 Heating flow and return connections
                                                mm                                                  22
 (pipe size)
 Hot and cold water connections
                                                mm                                                  15
 (pipe size)
                                             Stainless/
 Heat exchanger material                                                                      Stainless steel
                                             Aluminium
 Boiler lift weight (dry boiler)                 kg           36                        37                           41            44
 Maximum horizontal flue length 60/100           m            12                                            5.5
 Rear flue options                             Yes/No                                            No
 Permissible flue classifications                                                        C13, C33, C43, C53
 Minimum clearances
 Side left and right                            mm                                                  5
 Top                                            mm                                                 165
 Top (if using rear flue)                       mm                                                  -
 Below                                          mm                                                 180
 Front                                          mm                                                 500

*Achieved via fitment of a flow restrictor
                                                                                                                                             30
Technical data                                                Unit of measure      ecoTEC plus 938

      General
      Boiler type                                                                          Storage combi
      Signature model output                                               kW                   38
      Article number                                                                       0010021827
      Gas Council number                                                                    47-044-87
      Boiler dimensions (HxWxD)                                           mm              720 x 440 x 624
      Performance
      NOx (En 15502-2-1)                                                mg/kWh                   34
      ErP efficiency (heating / DHW)                                A+++ - D / A+ - F          A /A
      ErP efficiency                                                       %                    94
      ErP decibel rating (sound power)                                    dBa                   45
      Heating
      Nominal heat output range at 50/30˚C (condensing mode)               kW                7.1 - 30.9
      Nominal heat output range at 80/60˚C (non condensing mode)           kW                6.5 - 28.6
      Maximum flow temperature                                             ˚C                   85
      Flow temperature range                                               ˚C                 30 - 80
      Flow temperature factory setting                                     ˚C                    75
      Approximate condensate volume at 50/30˚C                          Litres/hr               2.9
      Modulation (max/min)                                                1:X                   1:6.0
      Domestic hot water
      Maximum heat output for water generation                             kW                   38.7
      Lowest water pressure to operate boiler                             Bar                   0.35
      Lowest water flow for operation                                     l/min                  2
      Lowest water pressure for maximum flow rate                         Bar                   0.8
      Domestic hot water flow rate (at ∆t = 35K)                          l/min                 15.9
      Domestic hot water flow rate (at ∆t = 42K)*                         l/min                 13.2
      Hot water output temperature range                                   ˚C                 35 - 65
      Mechanical
      Expansion vessel size                                              Litres                  10
      Gas inlet connection (pipe size)                                    mm                     15
      Heating flow and return connections (pipe size)                     mm                     22
      Hot and cold water connections (pipe size)                          mm                     15
      Heat exchanger material                                      Stainless/Aluminium     Stainless steel
      Boiler lift weight (dry boiler)                                      kg                  43+17
      Maximum horizontal flue length 60/100                                m                    5.5
      Rear flue options                                                  Yes/No                  No
      Permissible flue classifications                                                   C13, C33, C43, C53
      Minimum clearances
      Side left and right                                                 mm                     5
      Top                                                                 mm                    165
      Top (if using rear flue)                                            mm                      -
      Below                                                               mm                    180
      Front                                                               mm                    500

     *Achieved via fitment of a flow restrictor

31
Unit of                                            ecoTEC pro 28
 Technical data                                           ecoTEC pro 24 ecoTEC pro 28                              ecoTEC pro 30
                                             measure                                                 LPG
 General
 Boiler type                                                                             Combi
 Signature model output                          kW            24                         28                             30
 Article number                                            0010021836         0010021837     0010021838             0010016538
 Gas Council number                                        47-044-88          47-044-89        47-044-90             47-044-52
 Boiler dimensions (HxWxD)                      mm                                  720 x 440 x 338
 Performance
 NOx (En 15502-2-1)                           mg/kWh                     27                                28           30
                                             A+++ - D /
 ErP efficiency (heating / DHW)                                                              A /A
                                               A+ - F
 ErP efficiency                                  %                                94                                    93
 ErP decibel rating (sound power)               dBa                                           49
 Heating
 Nominal heat output range at 50/30˚C
                                                 kW         5.9 - 24.8         5.9 - 25.9             7.9 - 25.3     6.9 - 25.7
 (condensing mode)
 Nominal heat output range at 80/60˚C
                                                 kW         5.2 - 23.0          5.2 - 24              7.2 - 24.0     8.0 - 24.7
 (non condensing mode)
 Maximum flow temperature                        ˚C                                           85
 Flow temperature range                          ˚C                                         30 - 80
 Flow temperature
                                                 ˚C                                            75
 factory setting
 Approximate condensate
                                              Litres/hr                           1.9                                   2.5
 volume at 50/30˚C
 Modulation (max/min)                           1:X           1:4.3               1:5                   1:3.6          1:3.8
 Domestic hot water
 Maximum heat output for water
                                                 kW           23.5               27.5                   27.5           30.0
 generation
 Lowest water pressure to operate boiler        Bar                                           0.3
 Lowest water flow for operation               l/min                                           2
 Lowest water pressure
                                                Bar                                           0.8
 for maximum flow rate
 Domestic hot water flow rate
                                               l/min           9.6                11.1                     11.1         12.3
 (at ∆t = 35K)
 Domestic hot water flow rate
                                               l/min           8.0                            9.3                      10.2
 (at ∆t = 42K)*
 Hot water output temperature range              ˚C                                         35 - 65
 Mechanical
 Expansion vessel size                         Litres                                          8
 Gas inlet connection (pipe size)               mm                                             15
 Heating flow and return connections
                                                mm                                             22
 (pipe size)
 Hot and cold water connections
                                                mm                                             15
 (pipe size)
                                             Stainless/
 Heat exchanger material                                                                 Stainless steel
                                             Aluminium
 Boiler lift weight (dry boiler)                 kg                               38                                    39
 Maximum horizontal flue length 60/100           m                                           12
 Rear flue options                             Yes/No                                        No
 Permissible flue classifications                                                    C13, C33, C43, C53
 Minimum clearances
 Side left and right                            mm                                             5
 Top                                            mm                                            165
 Top (if using rear flue)                       mm                                             -
 Below                                          mm                                            180
 Front                                          mm                                            500

*Achieved via fitment of a flow restrictor

                                                                                                                                   32
Technical data                                Unit of measure ecoFIT pure 825   ecoFIT pure 830           ecoFIT pure 835

      General
      Boiler type                                                                          Combi
      Signature model output                              kW              25                 30                        35
      Article number                                                 0010020389        0010020390                 0010020391
      Gas Council number                                              47-044-68         47-044-74                  47-044-70
      Boiler dimensions (HxWxD)                          mm                           700 x 390 x 295
      Performance
      NOx (En 15502-2-1)                               mg/kWh             39                 39                        39
                                                     A+++ - D / A+
      ErP efficiency (heating / DHW)                                                        A /A
                                                         -F
      ErP efficiency                                      %                                  94
      ErP decibel rating (sound power)                   dBa              49                 51                        52
      Heating
      Nominal heat output range at 50/30˚C
                                                          kW           5.3 - 19.1         6.3 - 26.5                7.5 - 26.7
      (condensing mode)
      Nominal heat output range at 80/60˚C
                                                          kW           5.0 - 18.3         6.1 - 25.4               7.2 - 25.6
      (non condensing mode)
      Maximum flow temperature                             ˚C                                 80
      Flow temperature range                               ˚C                               10-80
      Flow temperature factory setting                     ˚C                                 75
      Approximate condensate volume at 50/30˚C         Litres/hr         1.84                2.55                     2.57
      Modulation (max/min)                                1:X            1:5.1               1:4.9                     1:5
      Domestic hot water
      Maximum heat output for water generation             kW            25.2                 30                       35
      Lowest water pressure to operate boiler             Bar                                0.3
      Lowest water flow for operation                    l/min                                 2
      Lowest water pressure for maximum flow rate         Bar                                  2
      Domestic hot water flow rate (at ∆t = 35K)         l/min           10.4                12.2                      14.1
      Domestic hot water flow rate (at ∆t = 42K)*        l/min            8.0                10.4                     12.0
      Hot water output temperature range                  ˚C                               35 - 60
      Mechanical
      Expansion vessel size                             Litres                               8
      Gas inlet connection (pipe size)                   mm                                  15
      Heating flow and return connections
                                                         mm                                  22
      (pipe size)
      Hot and cold water connections (pipe size)         mm                                  15
                                                      Stainless/
      Heat exchanger material                                                            Aluminium
                                                      Aluminium
      Boiler lift weight (dry boiler)                     kg              32                               33
      Maximum horizontal flue length 60/100               m                                   10
      Rear flue options                                 Yes/No                               Yes
      Permissible flue classifications                                                C13, C33, C43, C53
      Minimum clearances
      Side left and right                                mm                                   5
      Top                                                mm                                 150
      Top (if using rear flue)                           mm                                  20
      Below                                              mm                                 150
      Front                                              mm                                 500

     *Achieved via fitment of a flow restrictor

33
Technical data                                                Unit of measure      ecoTEC exclusive 627

General
Boiler type                                                                               System
Signature model output                                               kW                      27
Article number                                                                          0010017063
Gas Council number                                                                      41-694-02
Boiler dimensions (HxWxD)                                           mm                720 x 440 x 338
Performance
NOx (En 15502-2-1)                                                mg/kWh                    30
ErP efficiency (heating)                                          A+++ - D                   A
ErP efficiency                                                       %                      94
ErP decibel rating (sound power)                                    dBa                     46
Heating
Nominal heat output range at 50/30˚C (condensing mode)               kW                  3.4 - 26.7
Nominal heat output range at 80/60˚C (non condensing mode)           kW                  3.0 - 24.7
Maximum flow temperature                                             ˚C                     85
Flow temperature range                                               ˚C                   30 - 80
Flow temperature factory setting                                     ˚C                      75
Approximate condensate volume at 50/30˚C                          Litres/hr                 2.52
Modulation (max/min)                                                1:X                     1:8.9
Mechanical
Expansion vessel size                                              Litres                    10
Gas inlet connection (pipe size)                                    mm                       15
Heating flow and return connections (pipe size)                     mm                       22
Heat exchanger material                                      Stainless/Aluminium       Stainless steel
Boiler lift weight (dry boiler)                                      kg                     37.5
Maximum horizontal flue length 60/100                                m                      5.5
Rear flue options                                                  Yes/No                    No
Permissible flue classifications                                                       C13, C33, C53
Minimum clearances
Side left and right                                                 mm                       5
Top                                                                 mm                      165
Top (if using rear flue)                                            mm                        -
Below                                                               mm                      180
Front                                                               mm                      500

                                                                                                          34
Unit
                             of       ecoTEC             ecoTEC              ecoTEC             ecoTEC             ecoTEC        ecoTEC             ecoTEC       ecoTEC
     Technical data
                           meas-     plus 612           plus 615            plus 618           plus 618           plus 624      plus 630           plus 630     plus 637
                            ure
                                                                                                 LPG                                                 LPG
     General
     Boiler type                                                                                          System
     Signature model
                             kW          12                  15                          18                           24                     30                    37
     output
     Article number                  0010021828 0010021829 0010021830 0010021831 0010021832 0010021833 0010021834 0010021835
     Gas Council number              41-694-20 41-694-21 41-694-22 41-694-23 41-694-24 41-694-25 41-694-26 41-694-27
     Boiler dimensions                                                                                            720 x 440
                            mm                           720 x 440 x 338                       720 x 440 x 372
     (HxWxD)                                                                                                         x 406
     Performance
                           mg/
     NOx (En 15502-2-1)                  23                  23                29                  39                 35           29                 64           36
                           kWh
     ErP efficiency        A+++
                                                                                                             A
     (heating)              -D
     ErP efficiency          %                                                                               94
     ErP decibel rating
                            dBa                    43                                              47                                        46                    50
     (sound power)
     Heating
     Nominal heat output
     range at 50/30˚C       kW        3.3 - 13.2          3.3 - 16.7        4.1 - 20.0          5.4 - 19.4         5.7 - 26.4   6.4 - 32.8         9.4 - 31.9   7.1 - 40.5
     (condensing mode)
     Nominal heat output
     range at 80/60˚C
                            kW        3.0 - 12.2        3.0 - 15.2          3.8 - 18.2          5.0 - 18.2         5.2 - 24.4   5.8 - 30.4         8.5 - 30.4   6.4 - 37.6
     (non condensing
     mode)
     Maximum flow
                             ˚C                                                                              85
     temperature
     Flow temperature
                             ˚C                                                                           30 - 80
     range
     Flow temperature
                             ˚C                                                                              75
     factory setting
     Approximate           Litres/
     condensate                          1.2                 1.6                         1.9                          2.5                    3.1                   3.8
     volume at 50/30˚C       hr

     Modulation (max/
                            1:X         1:4.1               1:5.1             1:4.9               1:3.7              1:4.7               1:5.2                    1:5.9
     min)
     Mechanical
     Expansion vessel size litres                                                                            10
     Gas inlet connection
                            mm                                                                               15
     (pipe size)
     Heating flow and
     return
                            mm                                                                               22
     connections (pipe
     size)
     Heat exchanger
                                                                                                    Stainless steel
     material
     Boiler lift weight
                             kg                                        36                                             37                     38                    43
     (dry boiler)
     Maximum horizontal
                             m                     22.0                                  12.0                                                5.5
     flue length 60/100
     Rear flue options     Yes/No                                                                            No
     Permissible flue
                                                                                                  C13, C33, C43, C53
     classifications
     Minimum clearances
     Side left and right    mm                                                                                5
     Top                    mm                                                                               165
     Top (if using rear
                            mm                                                                                -
     flue)
     Below                  mm                                                                             180
     Front                  mm                                                                             500

35
Technical data                                      Unit of measure      ecoTEC plus 48                   ecoTEC plus 64

General
Boiler type                                                                                  System
Signature model output                                     kW                   48                              64
Article number                                                             0010021520                      0010021521
Gas Council number                                                          41-694-28                       41-694-29
Boiler dimensions (HxWxD)                                 mm             720 x 440 x 405                 720 x 440 x 473
Performance
NOx (En 15502-2-1)                                      mg/kWh                30.8                               29.1
ErP efficiency* (heating)                               A+++ - D                                A+
ErP efficiency                                             %                                    94
ErP decibel rating (sound power)                          dBa                                  56.5
Heating
Nominal heat output range at 50/30˚C
                                                           kW               8.7 - 48.0                      12.2 - 63.5
(condensing mode)
Nominal heat output range at 80/60˚C
                                                           kW               7.8 - 44.1                       11.0 - 58.7
(non condensing mode)
Conversion to LPG G31 at 37mb at 50/30˚C
                                                           kW               8.6 - 46.6                       12.0 - 62.1
(Conversion kit by installer on site necessary)
Conversion to LPG G31 at 37mb at 80/60˚C
                                                           kW               7.8 - 44.0                       11.0 - 58.4
((Conversion kit by installer on site necessary)
Maximum flow temperature                                    ˚C                                 80
Flow temperature range                                      ˚C                               30 - 80
Flow temperature factory setting                            ˚C                                 75
Approximate condensate volume at 50/30˚C                Litres/hr               5.0                              6.9
Modulation (max/min)                                       1:X             1:5.5 (18%)                      1:5.2 (19%)
Lowest water pressure to operate boiler                    bar                                 0.8
Nominal flow rate (at DT = 20K)                            l/hr               1900                               2500
Mechanical
Expansion vessel size                                      Litres                    Available as an accessory
Gas inlet connection (pipe size)                       BSP female                                 1”
Heating flow and return connections (pipe size)        BSP female                               1 1/4”
Heat exchanger material                            Stainless/Aluminium                     Stainless steel
Boiler lift weight (dry boiler - includes pump)              kg                38                                48
Maximum horizontal flue length 80/125                        m                 18                                15
Maximum vertical flue length 80/125                          m                 21                                18
Rear flue options                                         Yes/No                               No
Permissible flue classifications                                         C13, C33, C43, C53, C93, B23, B23p, B53, B53p
Minimum clearances
Side left and right                                       mm                                    5
Top                                                       mm                                   350
Top (if using rear flue)                                  mm                                    -
Below                                                     mm                                   400
Front                                                     mm                                   500

*When installed with a VRC 7O0

                                                                                                                           36
Unit of        ecoFIT        ecoFIT            ecoFIT            ecoFIT             ecoFIT
     Technical data
                                                 measure       pure 612      pure 615          pure 618          pure 625           pure 630

     General
     Boiler type                                                                           System
     Signature model output                          kW            12            15           18           25                           30
     Article number                                           0010020395    0010020396 0010020397 0010020398                       0010020399
     Gas Council number                                        41-694-03     41-694-04    41-694-05    41-694-06                    41-694-07
     Boiler dimensions (HxWxD)                      mm                                 700 x 390 x 295
     Performance
     NOx (En 15502-2-1)                           mg/kWh          32            33                          39                         40
     ErP efficiency (heating)                    A+++ - D                                         A
     ErP efficiency                                  %                                           94
     ErP decibel rating (sound power)               dBa           45            48                49                51                 54
     Heating
     Nominal heat output range at 50/30˚C
                                                     kW        4.7 - 12.8    4.7 - 15.9        5.2 - 19.1        6.4 - 26.5         7.5 - 31.8
     (condensing mode)
     Nominal heat output range at 80/60˚C
                                                     kW        4.5 - 12.3    4.5 - 15.2        5.0 - 18.3        6.1 - 25.4         7.2 - 30.5
     (non condensing mode)
     Maximum flow temperature                        ˚C                                          80
     Flow temperature range                          ˚C                                        10 - 80
     Flow temperature factory setting                ˚C                                          75
     Approximate condensate
                                                  Litres/hr      1.23          1.53              1.84              2.55               3.06
     volume at 50/30˚C
     Modulation (max/min)                           1:X          1:3.3          1:4               1:5              1:4.9              1:4.9
     Mechanical
     Expansion vessel size                         Litres                                        8
     Gas inlet connection (pipe size)               mm                                           15
     Heating flow and return connections (pipe
                                                    mm                                           22
     size)
                                                 Stainless/
     Heat exchanger material                                                                 Aluminium
                                                 Aluminium
     Boiler lift weight (dry boiler)                 kg                         31                                            32
     Maximum horizontal flue length 60/100           m                                            10
     Rear flue options                             Yes/No                                        Yes
     Permissible flue classifications                                                     C13, C33, C43, C53
     Minimum clearances
     Side left and right                            mm                                            5
     Top                                            mm                                          150
     Top (if using rear flue)                       mm                                           20
     Below                                          mm                                          150
     Front                                          mm                                          500

37
Unit of       ecoTEC           ecoTEC             ecoTEC            ecoTEC         ecoTEC plus              ecoTEC             ecoTEC
Technical data
                            measure      plus 412         plus 415           plus 418          plus 424         424 LPG                plus 430           plus 435

General
Boiler type                                                               Open vent
Signature model output         kW            12         15         18               24              30         35
Article number                          0010021220 0010021221 0010021222 0010021223 0020231355 0010021224 0010015674
Gas Council number                       41-694-13  41-694-14  41-694-15  41-694-16    41-694-18 41-694-17 41-044-76
Boiler dimensions
                              mm                                                          602 x 375 x 320
(HxWxD)
Performance
NOx (En 15502-2-1)          mg/kWh          32               33                 39                39                  35                  40                 29
ErP efficiency
                            A+++ - D                                                               A
(heating)
ErP efficiency                 %                                                          94                                                                 93
ErP decibel rating
                              dBa           45               48                 51                52                  49                  55                 53
(sound power)
Heating
Nominal heat output
range at 50/30˚C               kW        4.7 - 12.8       4.7 - 15.9         5.2 - 19.1        6.3 - 25.7          8.0 - 25.7          7.5 - 31.8         7.5 - 37.1
(condensing mode)
Nominal heat output
range at 80/60˚C               kW        4.5 - 12.3       4.5 - 15.2         5.0 - 18.3        6.1 - 24.6          7.6 - 24.3          7.2 - 30.5         7.1 - 35.1
(non condensing mode)
Maximum flow
                               ˚C                                                                 80
temperature
Flow temperature range         ˚C                                                               10 - 80
Flow temperature
                               ˚C                                                                 75
factory setting
Approximate condensate
                            Litres/hr      1.23              1.53              1.84                         2.47                         3.06               3.57
volume at 50/30˚C
Modulation (max/min)          1:X          1:2.8            1:3.5              1:3.8             1:4.2               1:3.4               1:4.4              1:5.2
Mechanical
Gas inlet connection
                              mm                                                                  15
(pipe size)
Heating flow and return
                              mm                                                                  22
connections (pipe size)
Heat exchanger material                                                                        Aluminium
Boiler lift weight
                               kg                           23.0                                                                23.8
(dry boiler)
Maximum horizontal flue
                               m                                       10                                            0.7*                           10
length 60/100
Rear flue options            Yes/No                                    Yes                                            No                            Yes
Permissible flue
                                                   C13, C33, C43, C53 (LPG option can only be fitted with top horizontal flue supplied)
classifications
Minimum clearances
Side left and right           mm                                                                   5
Top                           mm                                                                 150
Top (if using rear flue)      mm                                                                  75
Below                         mm                                                                 150
Front                         mm                                                                 500

*Cannot be extended with any other standard Vaillant flue component. 0.7m flue is supplied with this boiler.